Showing 145–156 of 1333 results

CHINT NC1 3-Pole Magnetic Motor Contactor, 9–95 A

CHINT NC1 contactors provide remote making and breaking of motor circuits. This listing focuses on three-pole motor switching. Specify the built-in auxiliary contacts and the exact coil code for the starter assembly.

NOARK UL 489 M4 3P Thermal-Magnetic MCCB, 400A–600A

Series illustration. Original NOARK M4 circuit breakers provide adjustable thermal and magnetic protection. This page covers the three-pole 400A, 500A and 600A S/N/H ordering rows.

NOARK A32/A40 UL 1066 Air Circuit Breaker, 800–4000A

Original NOARK A32 (800–3200A) and A40 (4000A) UL 1066 air circuit breakers. Select the series, documented mounting/terminal/current combination, poles, breaking class and trip protection; trip unit and accessories are specified separately.

CHINT BH-0.66 I Class Low Voltage Current Transformer

Brand Name: CHINT
Product Type: Current Transformer
Series: BH-0.66 I
Secondary Current: 5A / 1A
Rated Voltage: 660V
Frequency: 50Hz / 60Hz
Installation: Busbar or plate fixing
Standard: IEC 61869-2
Application: Ammeters, watt-hour meters, measurement units, control relays and low-voltage distribution monitoring

CHINT NH40SZ 1250A 4P Automatic Changeover Switch

Series illustration: photo shows a16A/4P unit. This page is 1250A/4P.

CHINT NH40SZ transfers the 1250A,4-pole load between two supplies. Select the common,SZI,SZII or SZIII controller to match mains/mains or mains/generator operation.

NewTrend QO 2P Plug-In Circuit Breaker, 10–60A, 10kA

NewTrend QO 2P plug-in thermal-magnetic circuit breaker, 10–60A, AC 120/240V, 10kA. 38.10 mm nominal width with visible trip indication, for NewTrend QOD and QOL load centers.

NewTrend QO 2P Plug-In Circuit Breaker, 10–60A, 10kA

NewTrend QO 2P plug-in thermal-magnetic circuit breaker, 10–60A, AC 120/240V, 10kA. 38.10 mm nominal width with visible trip indication, for NewTrend QOD and QOL load centers.

3-Phase MCB/MCCB Main Breaker Distribution Board 4-16 Ways

The TD01 overview describes incomer options, outgoing-device arrangement and surface or flush enclosure construction. The original dimensions and assembly references remain below.

Warranty: 2 Years

NewTrend BH Bolt-On Circuit Breaker, 1P–3P, 5–100A, 3kA

NewTrend BH bolt-on thermal-magnetic circuit breaker with Type C tripping. 1P: 5–60A; 2P/3P: 5–100A. AC 230/400V for 1P and AC 400V for 2P/3P, with a 3kA AC interrupting rating. Module width: 25 mm per pole.

NewTrend DC66P 50 A DC Reversing Contactor

This NewTrend / OEM reversing assembly uses paired changeover contacts to reverse a suitable DC motor circuit. Select the continuous and intermittent duty separately, and match the coil supply and terminal layout to the controller.

DC88P 100A/500A 12V/24V SPDT DC Contactor for Motor Reversing

The retained comparison lists W50 and W100 motor-reversing contactor constructions. Match the exact current frame, coil supply and terminal arrangement.

NewTrend LC1-D AC/DC Coil Magnetic Contactor LC1D09 to LC1D95

This LC1D family listing concerns motor-control contactors with separate AC-coil and DC-coil constructions. Select the complete frame, poles and coil code.