Showing all 11 results

G2R Mini ATS Dual Power Selector Switch 2P 32A-63A

The G2R-63 overview describes automatic transfer between normal and standby AC sources.

Warranty: 18Month

DIN Rail PV Solar Automatic Transfer Switch 2P-4P

The original NLQ4 page identifies a special PV-system-to-city-power transfer application and supplies the associated AC system references and diagrams.

Warranty: 12 months

Dual Power Automatic Transfer Switch ATS 63A/100A

The W2R overview describes DIN-rail automatic and manual transfer between normal and standby AC supplies. Specify the complete current, pole and controller configuration.

Warranty: 1 Year

NewTrend OQ7-100PV/4 PV Inverter Automatic Transfer Switch, 4P, 100A

4P100A PV/inverter-to-grid ATS, L+N220–230V control, manual/automatic modes and <50ms transfer reference. Inverter/PV to source A, stable utility to source B; B must remain powered for this PV type.

NewTrend OQ5-125A/4P Automatic Transfer Switch, 4P, 125A

4P125A PC-class DIN-rail ATS for utility and generator sources, AC220–230V L+N control reference, manual/automatic modes and <8ms transfer reference. Not the PV/inverter version.

NewTrend PS8-17 Single-Phase Automatic Transfer Switch, 63A

Two AC 220V single-phase sources to one L-N load. Adjustable L1/L2/AUTO priority, voltage and overcurrent protection; 63A AC-1. N1 and N2 are internally connected.

NewTrend PS8-15 Automatic Phase Selector Switch, 63/80A

Automatic phase selector: three-phase four-wire input, single-phase L-N output. 63A/80A AC-1, adjustable voltage thresholds and recovery timing.

NewTrend PS8-16 Automatic Phase Selector with Overcurrent Protection, 63/80A

Automatic phase selector: three-phase four-wire input, single-phase L-N output. 63A/80A AC-1, adjustable voltage thresholds and recovery timing. Adds load-current monitoring and a 1-63A overcurrent setting.

NewTrend PS8-18 Priority Phase Selector Switch, 63A

Three-phase four-wire input to one single-phase L-N load. Adjustable L1/L2/L3/AUTO priority, voltage and overcurrent protection; 63A AC-1. This is not a three-phase load output.

NewTrend OQ7-63/2 Automatic Transfer Switch, 2P, 63A, AC110–120V

2P63A PC-class DIN-rail ATS for L+N110–120V50/60Hz systems. Utility/generator source arrangement, manual/automatic modes and <50ms switching reference. The 230V and PV versions are separate variants.

NewTrend OQ5-250A/4P Automatic Transfer Switch, 250A, AC400V

4P250A AC400V automatic transfer switch with normal-source priority, manual/automatic modes and two inputs/one output. Supply is interrupted during transfer; written switching-time reference <2.5s. Does not start or stop a generator.