NewTrend · BH Series · Bolt-On Circuit Breaker
Product overview
The NewTrend BH is a bolt-on thermal-magnetic miniature circuit breaker for branch-circuit protection in electrical distribution assemblies. Screw-secured connections provide a fixed connection to matched conductors and busbars, with manual ON/OFF switching and automatic overload and short-circuit tripping.
Available as 1P, 2P and 3P configurations. The single-pole range is 5–60A; the two- and three-pole ranges are 5–100A. Select the pole count, current and AC voltage for the circuit being protected.
Key features
- Bolt-on connection: Screw-secured line and load connections for matched panel assemblies.
- Thermal-magnetic protection: Protection against sustained overloads and short circuits.
- Pole-specific current ranges: 1P: 5–60A; 2P and 3P: 5–100A in the listed ratings.
- 3 kA AC interrupting rating: 1P at AC 230/400V; 2P and 3P at AC 400V.
- 25 mm module width: Overall widths of 25, 50 and 75 mm for 1P, 2P and 3P.
Technical selection summary
| Brand | NewTrend |
|---|---|
| Series | BH |
| Product type | Bolt-on thermal-magnetic miniature circuit breaker |
| Number of poles | 1P / 2P / 3P |
| Rated current — 1P | 5, 10, 15, 20, 25, 30, 40, 50, 60A |
| Rated current — 2P / 3P | 5, 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100A |
| AC voltage — 1P | 230/400V |
| AC voltage — 2P / 3P | 400V |
| AC interrupting capacity | 3 kA |
| Instantaneous tripping | Type C |
| Reference ambient temperature | 40°C |
| Connection | Bolt-on; screw terminals |
| Operation | Manual ON/OFF switching and automatic tripping |
BH Selection Table
| Product | Model | Poles | Rated Current | Rated Voltage |
|---|---|---|---|---|
BH 1P | BH | 1P | 5A | AC 230/400V |
| BH | 1P | 10A | AC 230/400V | |
| BH | 1P | 15A | AC 230/400V | |
| BH | 1P | 20A | AC 230/400V | |
| BH | 1P | 25A | AC 230/400V | |
| BH | 1P | 30A | AC 230/400V | |
| BH | 1P | 40A | AC 230/400V | |
| BH | 1P | 50A | AC 230/400V | |
| BH | 1P | 60A | AC 230/400V | |
BH 2P | BH | 2P | 5A | AC 400V |
| BH | 2P | 10A | AC 400V | |
| BH | 2P | 15A | AC 400V | |
| BH | 2P | 20A | AC 400V | |
| BH | 2P | 25A | AC 400V | |
| BH | 2P | 30A | AC 400V | |
| BH | 2P | 40A | AC 400V | |
| BH | 2P | 50A | AC 400V | |
| BH | 2P | 60A | AC 400V | |
| BH | 2P | 70A | AC 400V | |
| BH | 2P | 80A | AC 400V | |
| BH | 2P | 90A | AC 400V | |
| BH | 2P | 100A | AC 400V | |
| BH 3P | BH | 3P | 5A | AC 400V |
| BH | 3P | 10A | AC 400V | |
| BH | 3P | 15A | AC 400V | |
| BH | 3P | 20A | AC 400V | |
| BH | 3P | 25A | AC 400V | |
| BH | 3P | 30A | AC 400V | |
| BH | 3P | 40A | AC 400V | |
| BH | 3P | 50A | AC 400V | |
| BH | 3P | 60A | AC 400V | |
| BH | 3P | 70A | AC 400V | |
| BH | 3P | 80A | AC 400V | |
| BH | 3P | 90A | AC 400V | |
| BH | 3P | 100A | AC 400V |
Dimensions — BH
| Poles | Width | Body Height | Body Depth |
|---|---|---|---|
| 1P | 25 mm | 95 mm | 57.5 mm |
| 2P | 50 mm | 95 mm | 57.5 mm |
| 3P | 75 mm | 95 mm | 57.5 mm |
Depth including the operating handle: 77.5 mm. Overall mounting-bracket height: 113 mm. Use the outline drawing below for mounting holes and conductor drilling.
Installation and operation
Select the rated current to suit the circuit load and conductor rating. Match the bolt-on terminals, busbar drilling and mounting brackets to the panel assembly. After a trip, clear the fault, move the handle fully to OFF, then switch to ON. Installation and servicing should be carried out by qualified personnel with the supply isolated.
Typical applications
- Branch-circuit protection in matching electrical distribution assemblies.
- Residential, commercial and light-industrial AC distribution circuits.
- Panel assembly and maintenance with matching bolt-on connections.
Outline and mounting dimensions

Time-current characteristics — 70A / 100A

Temperature compensation — 70A / 100A