NewTrend / OEM · DC reversing contactor
Product overview
This NewTrend / OEM reversing assembly uses paired changeover contacts to reverse a suitable DC motor circuit. Select the continuous and intermittent duty separately, and match the coil supply and terminal layout to the controller.
Technical selection summary
| Model reference | W50-T-P-DE / DC66P |
|---|---|
| Contact arrangement | Paired SPDT / double-pole changeover |
| Continuous-current reference | 50 A in the supplied model table |
| Intermittent-current reference | 200 A; allowable duration must be confirmed |
| Main-circuit reference | Max 80V DC; coil voltage is specified separately |
| Listed coil choices | 12 V DC or 24 V DC; confirm full version |
An intermittent-current value is not a continuous-current rating. Confirm control interlocking, terminal numbering and motor stall current. Neither third-party interchangeability nor marine ingress protection is established by the family name.
Typical applications
- Winch motor-control assemblies
- Low-voltage DC motor reversal
- OEM equipment selected by duty
Main circuit voltage: Max 80V DC for the supplied NewTrend version. Coil voltage is selected separately. Any 48V contact-circuit marking in retained legacy reference drawings describes the earlier reference, not the current supplied rating.
Product reference images and drawings
Compare the exact model, voltage and duty. Reference tables may include other frames or versions; confirm the ordered configuration before using any rating or dimension.