NewTrend · LCD voltage and current protector
Product overview
NewTrend PS8-05 provides adjustable overvoltage, undervoltage and overcurrent protection for AC 220V line-to-neutral circuits. Its backlit LCD shows voltage and current, while separate indicators identify protection and output status. This is the local-control version, without the Wi-Fi connectivity listed for PS8-06. Choose a 32A, 40A, 50A, 63A or 80A AC-1 rating and the upper- or lower-incoming factory wiring version. Voltage-fault, overcurrent, power-up and reset delays can be adjusted.
Technical selection summary
| Model | PS8-05 |
|---|---|
| Protection functions | Overvoltage, undervoltage and overcurrent |
| Display | Backlit LCD voltage and current; separate status indicators |
| Rated supply voltage | AC 220V (L-N) |
| Supply frequency | 45-65Hz |
| Operating voltage range | 80-400V (L-N) |
| Rated operational currents | 32A / 40A / 50A / 63A / 80A, AC-1 |
| Incoming-line versions | PS8-05U: upper incoming; PS8-05D: lower incoming |
| Power input | Maximum 3VA |
| Overvoltage setting | OFF or 230-300V |
| Undervoltage setting | 140-210V or OFF |
| Voltage-fault action delay | 0.1-10s |
| Overcurrent setting | 1A up to the selected rated current: 32 / 40 / 50 / 63 / 80A |
| Overcurrent action delay | 2-600s |
| Wi-Fi connectivity | Not provided on this version |
| Power-up delay | 2-600s |
| Reset delay | 2-900s |
| Measurement error | ≤1% |
| Electrical life (AC-1) | 10,000 operations |
| Mechanical life | 1,000,000 operations |
| Operating temperature | -20 to +60°C |
| Storage temperature | -35 to +75°C |
| Mounting | DIN rail to EN/IEC 60715 |
| Protection | IP40 front panel / IP20 terminals |
| Operating position | Any |
| Overvoltage category / pollution degree | III / 2 |
| Body dimensions | 82 x 36 x 68mm |
Operation
- Select the rated current and the factory U (upper incoming) or D (lower incoming) wiring configuration.
- Set overvoltage to OFF or 230-300V and undervoltage to 140-210V or OFF. The voltage-fault action delay is adjustable from 0.1-10s.
- Set the overcurrent threshold from 1A up to the selected rated current and its delay within 2-600s. Power-up delay is 2-600s and reset delay is 2-900s.
- Hold the M setting key for 3s to enter settings; after editing, hold for 3s to save. The decrease/power key can manually control the load after leaving settings and can provide manual reset when automatic fault reset is disabled.
Typical applications
- Household-equipment protection against abnormal supply voltage and overcurrent
- DIN-rail distribution panels requiring a voltage/current LCD and adjustable automatic recovery
View or download PS8-05/06 LCD voltage/current-protector catalogue, September 2026 (PDF)
Product reference images and drawings
Original September 2026 model coding and exact-model LCD-protector parameters
Original timing diagrams, model-specific panel controls, wiring and dimensions
Use the selected U or D incoming-line wiring diagram and set the overcurrent threshold within the ordered current rating. The shared catalogue photograph illustrates the PS8-05 40A upper-incoming version; the model-specific panel drawings distinguish the Wi-Fi controls. Coordinate separate upstream circuit and short-circuit protection for the installation. Installation and wiring must be performed by qualified electricians.