NewTrend · color-display voltage/current/leakage protector
Product overview
NewTrend PS8-09 combines adjustable overvoltage, undervoltage, overcurrent and leakage-current settings with automatic recovery and a configurable leakage-reclosing count. Its color display shows voltage, current, leakage current, frequency, power factor, power and accumulated energy. This is the local-control version. Select a 32A, 40A, 50A, 63A or 80A AC-1 rating and the factory upper- or lower-incoming wiring version for an AC 220V line-to-neutral circuit. The DIN-rail enclosure is 54mm wide.
Technical selection summary
| Model | PS8-09 |
|---|---|
| Protection settings | Overvoltage, undervoltage, overcurrent and leakage current |
| Display quantities | Voltage; current; leakage current; frequency; power factor; power; accumulated energy |
| Rated supply voltage | AC 220V (L-N) |
| Supply frequency | 45-65Hz |
| Operating voltage range | 80-400V (L-N) |
| Rated operational currents | 32A / 40A / 50A / 63A / 80A, AC-1 |
| Incoming-line versions | PS8-09U: upper incoming; PS8-09D: lower incoming |
| Power input | Maximum 3VA |
| Overvoltage setting | OFF or 230-300V |
| Undervoltage setting | 140-210V or OFF |
| Voltage-fault action delay | 0.1-10s |
| Overcurrent setting | 1A up to the selected rated current: 32 / 40 / 50 / 63 / 80A |
| Overcurrent action delay | 2-600s |
| Leakage-current setting | OFF or 10-400mA |
| Leakage-reclosing count | OFF / 1-20 / ON; see original function diagram |
| Leakage response shown in diagram | t≤0.2s |
| Wi-Fi connectivity | Not provided on this version |
| Power-up delay | 2-600s |
| Reset delay | 2-900s |
| Measurement error (factory table) | ≤1% |
| Electrical life (AC-1) | 10,000 operations |
| Mechanical life | 1,000,000 operations |
| Operating temperature | -20 to +60°C |
| Storage temperature | -35 to +75°C |
| Mounting | DIN rail to EN/IEC 60715 |
| Protection | IP40 front panel / IP20 terminals |
| Operating position | Any |
| Overvoltage category / pollution degree | III / 2 |
| Body dimensions | 82 x 54 x 68mm |
| Weight (current catalogue) | 205g |
Operation
- Select the rated-current version and U (upper incoming) or D (lower incoming) wiring. Connect the AC 220V supply and neutral according to the exact diagram.
- Set overvoltage to OFF or 230-300V, undervoltage to 140-210V or OFF, and voltage-fault delay within 0.1-10s.
- Set overcurrent from 1A up to the selected rated current and its delay within 2-600s. Power-up delay is 2-600s and reset delay is 2-900s.
- Leakage-current setting is OFF or 10-400mA. Leakage reclosing can be disabled, limited to 1-20 attempts, or set to ON as described in the original catalogue. After the configured attempt limit is exceeded, the unit remains open with fault indication until manual reset.
- The original leakage timing diagram illustrates a three-attempt setting and a response marked t≤0.2s; use the configured mode and the exact installation protection arrangement.
Typical applications
- Household-equipment circuits requiring configurable abnormal-voltage and current monitoring
- DIN-rail distribution panels with leakage-current setting and controlled reconnection requirements
View or download PS8-09 voltage/current/leakage-protector catalogue, September 2026 (PDF)
Product reference images and drawings
Original September 2026 exact-model protection parameters and U/D model code
Original leakage/reclosing timing, separate companion breaker, wiring and dimensions
Follow the selected U or D incoming-line wiring and set the overcurrent threshold within the ordered current rating. Confirm the leakage threshold, reclosing mode and permitted reset behavior for the installation. The RD9L-R residual-current breaker and circuit breakers in the original application diagram are separate companion devices; their ratings and standards are not specifications or certification claims for PS8-09. Installation and wiring must be performed by qualified electricians.