People Electric · Screw Terminal Block
Product overview
People Electric TB terminal blocks provide screw pressure-plate connections in electrical control systems. Complete model selection fixes the current and number of terminal positions. The source lists 3/4/6/12-position versions for 15A and 25A, and 3/4/6-position versions for 45A and 60A.
Technical selection summary
| Manufacturer / series | Original People Electric TB |
|---|---|
| Rated voltage | AC600V |
| Construction | Thermosetting insulating plastic with screw pressure-plate connections |
| Conductor size, series statement | 0.75–25mm² is stated for the series; confirm conductor size and termination for the selected current model. |
| TB-1503 | 15A; 3 terminal positions; L=46, L1=35.5, A=7.5, B=9, C=M3, D=22, E=17, as tabulated |
| TB-1504 | 15A; 4 terminal positions; L=55, L1=43.5, A=7.5, B=9, C=M3, D=22, E=17, as tabulated |
| TB-1506 | 15A; 6 terminal positions; L=73, L1=63.5, A=7.5, B=9, C=M3, D=22, E=17, as tabulated |
| TB-1512 | 15A; 12 terminal positions; L=127, L1=115, A=7.5, B=9, C=M3, D=22, E=17, as tabulated |
| TB-2503 | 25A; 3 terminal positions; L=50, L1=44.5, A=10.5, B=12, C=M4, D=30, E=20, as tabulated |
| TB-2504 | 25A; 4 terminal positions; L=62.5, L1=57, A=10.5, B=12, C=M4, D=30, E=20, as tabulated |
| TB-2506 | 25A; 6 terminal positions; L=91, L1=81.5, A=10.5, B=12, C=M4, D=30, E=20, as tabulated |
| TB-2512 | 25A; 12 terminal positions; L=163, L1=153, A=10.5, B=12, C=M4, D=30, E=20, as tabulated |
| TB-4503 | 45A; 3 terminal positions; L=70, L1=60.5, A=15, B=15, C=M5, D=38, E=23.5, as tabulated |
| TB-4504 | 45A; 4 terminal positions; L=86, L1=75.5, A=15, B=15, C=M5, D=38, E=23.5, as tabulated |
| TB-4506 | 45A; 6 terminal positions; L=120.5, L1=110, A=15, B=15, C=M5, D=38, E=23.5, as tabulated |
| TB-603 | 60A; 3 terminal positions; L=70.5, L1=65.5, A=15.5, B=15.5, C=M6, D=38, E=31, as tabulated |
| TB-604 | 60A; 4 terminal positions; L=93.5, L1=82.5, A=15.5, B=15.5, C=M6, D=38, E=31, as tabulated |
| TB-606 | 60A; 6 terminal positions; L=129, L1=118, A=15.5, B=15.5, C=M6, D=38, E=31, as tabulated |
| Dimension notation | Dimensions retain the original L/L1/A/B/C/D/E/F/G symbols. Match them to the manufacturer assembly drawing and confirm installation space before ordering. |
| Gallery scope | Original series examples; delivered model, terminal positions and included cover/parts must match the enquiry. |
This listing covers the unambiguous TB 15–60A rows only. The shared table also contains TB-(C)-1003/1004/1006 labels; their TB/TC construction identity requires confirmation and they are not offered here. Do not infer a 12-position 45A or 60A model.
Typical applications
- Industrial electrical-device and control-system terminal connections.
- Replacement or installation work requiring a documented complete terminal-block model.
Specify your enquiry
For a focused quotation, include:
- Complete model, terminal-position count and quantity.
- Circuit voltage/current, conductor type and cross-section, and suitable lug/ferrule details.
- Installation clearance, required cover/accessories and destination.
Download People Electric TB catalogue (PDF)