People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
  • Home
  • Products
    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Automation & Control

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Circuit Breaker & Fuses

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Din-Rail Mounted Products

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Distribution Box & Cabinet

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Load Center & Meter Bases

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Solar PV Products

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Electrical Accessories

    Tmax T7S 1000A MCCB 3P/4P PR332/P LSIG

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
Search
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
Click to enlarge
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
Home Electrical Accessories Others People Electrical Materials People New Energy People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
NewTrend XB45 Distribution Enclosure, 45-72 Modules
NewTrend XB45 Distribution Enclosure, 45-72 Modules
Back to products
NewTrend Analogue Panel Meter, 72×72 /96×96mm Enquiry
NewTrend Analogue Panel Meter, 72×72 /96×96mm Enquiry

People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA

Original People Electric RDU8DC DC surge protective device. Select B20 (Imax 20kA) or B40 (Imax 40kA), and 2P or 3P. This page covers the DC1000V maximum continuous operating-voltage ratings.

Model
Poles
Version
Maximum Continuous Voltage
Request a Quote

Send quantities and requirements together. Availability and final specifications are confirmed with your quotation.

SKU: RDU8DC Categories: People Electrical Materials, People New Energy
  • Description
  • Additional information
  • Technical Documents
  • Selection & Ordering
Description

People Electric · DC Surge Protective Device

Product overview

People Electric RDU8DC surge protective devices limit transient overvoltage on DC power lines by diverting surge current to earth. Choose the discharge-current version and pole arrangement to suit the DC system and earthing design. Nominal discharge current and maximum discharge current are different ratings.

Technical selection summary

Manufacturer / seriesOriginal People Electric RDU8DC
B20 versionRDU8DC-B20: nominal discharge current In 10kA; maximum discharge current Imax 20kA
B40 versionRDU8DC-B40: nominal discharge current In 20kA; maximum discharge current Imax 40kA
Maximum continuous operating voltage (Uc)DC1000V, for the ratings covered on this page
Pole configurations2P or 3P; follow the manufacturer installation diagrams
Response time≤25ns
Operating / storage temperature-40 to +70°C
Altitude≤2,000m
Protection / pollution degreeIP20; pollution degree 2
MountingVertical within ±5°, or horizontal, as stated in the source
Dimensions54 × 68 × 90mm shown for the illustrated 3P assembly; see original drawing and exact configuration

B20 and B40 identify maximum discharge current, not a continuous load-current rating. This listing uses the DC1000V rating explicitly tabulated by the manufacturer. Other voltage examples in the series selection diagram are not offered as a freely interchangeable rating. Confirm earthing arrangement, backup protection and the exact Uc for the actual DC system.

Typical applications

  • Transient overvoltage protection of DC distribution and power-protection circuits.
  • DC installations requiring coordinated surge protection and suitable earth connections.

Specify your enquiry

For a focused quotation, include:

  • B20 or B40, 2P or 3P, maximum DC operating voltage and earthing arrangement.
  • Backup protective device, alarm requirements, installation conditions, quantity and destination.

Product reference images and drawings

People Electric RDU8DC technical-1

People Electric RDU8DC technical-2

Additional information
Model

RDU8DC

Version

B20, B40

Poles

2P, 3P

Maximum Continuous Voltage

DC 1000V

Technical Documents

TECHNICAL RESOURCES

Documents for People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA

A downloadable document is not currently attached to this listing. Request the datasheet for your required model and configuration.

Request a datasheet

Drawings and compliance documents

Tell us the model and destination market if you need dimensions, a wiring diagram or a certification document. Available documents and approvals depend on the exact product configuration.

Ask for product documents

Supplier: Shanghai Newtrend Electric Co., Ltd. Brand and manufacturer details are stated separately for each product.

Selection & Ordering

BEFORE YOU ORDER

Selection and ordering questions

What information is needed for a quotation?

Send the exact model or selected configuration, required quantity, destination country and any project-specific requirements. Our team will confirm availability and the matching specification.

Are the same approvals available for every configuration?

No. Standards, certificates and market acceptance must be checked for the exact manufacturer model and configuration. Request the relevant document before specifying the product.

Can I include other products in the same enquiry?

Yes. Add the required products to your quote list, set the quantities and send one enquiry with your project requirements.

Related products

People Electric RDB5-80S Prepaid Miniature Circuit Breaker, 40–80A
People Electric RDB5-80S Prepaid Miniature Circuit Breaker, 40–80A

People Electric RDB5-80S Prepaid Miniature Circuit Breaker, 40–80A

Original People Electric RDB5-80S AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDR6 Thermal Overload Relay, 0.1–93A
People Electric RDR6 Thermal Overload Relay, 0.1–93A

People Electric RDR6 Thermal Overload Relay, 0.1–93A

Original People Electric RDR6 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric RDPV8-H PV Combiner Box, 6–16 Circuits

People Electric RDPV8-H PV Combiner Box, 6–16 Circuits

Original People Electric RDPV8-H photovoltaic combiner box, custom-built for AC or DC systems with 6, 8, 10, 12 or 16 circuits. Electrical ratings and internal protection are confirmed for each project.
People Electric CJX1 3-Pole AC Contactor, 9–400A AC-3
People Electric CJX1 3-Pole AC Contactor, 9–400A AC-3

People Electric CJX1 3-Pole AC Contactor, 9–400A AC-3

Original People Electric CJX1 three-pole AC contactor. Current buttons refer to AC-3 at 380V. Select rated current, auxiliary contacts, the manufacturer-listed paired coil voltage and operating frequency.
People Electric RDX6-40 1P+N Miniature Circuit Breaker, 1–40A 6kA
People Electric RDX6-40 1P+N Miniature Circuit Breaker, 1–40A 6kA

People Electric RDX6-40 1P+N Miniature Circuit Breaker, 1–40A 6kA

Original People Electric RDX6-40 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDW8HU Air Circuit Breaker, 630–6300A, AC800–1140V
People Electric RDW8HU Air Circuit Breaker, 630–6300A, AC800–1140V

People Electric RDW8HU Air Circuit Breaker, 630–6300A, AC800–1140V

Original People Electric RDW8HU air circuit breaker for AC800V, AC1000V or AC1140V distribution. Select the frame and supported current, poles, controller, installation/connection and auxiliary control voltage.
People Electric RDR5 Thermal Overload Relay, 0.1–93A
People Electric RDR5 Thermal Overload Relay, 0.1–93A

People Electric RDR5 Thermal Overload Relay, 0.1–93A

Original People Electric RDR5 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric RDC6 3-Pole AC Contactor, 9–95A AC-3
People Electric RDC6 3-Pole AC Contactor, 9–95A AC-3

People Electric RDC6 3-Pole AC Contactor, 9–95A AC-3

Original People Electric RDC6 three-pole AC contactor, 9–95A AC-3 at 380V. Select current and auxiliary contacts; specify the exact coil voltage and frequency in your enquiry for confirmation.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
      • People Electrical Materials
        • People New Energy
        • People MCB
        • People RCCB RCBO
        • People MCCB ACB
          • People Moulded Case Circuit Breakers
          • People Air Circuit Breakers
        • People Contactor & Overload Relays
        • People Relays
        • People Fuse & Disconnectors
        • People Inverter & Soft Starters
        • People Pushbutton & Pilot Lights
        • People Changeover Switches
        • People Capacitor & Reactors
        • People Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • CHINT NJJ5-J Digital Electronic Counter Relay CHINT NJJ5-J Digital Electronic Counter Relay
  • NewTrend LC1D40008 / 65008 / 80008 4P AC Contactor NewTrend LC1D40008 / 65008 / 80008 4P AC Contactor
  • DC66P 12V/24V Monoblock Direct Current Motor Reversing Contactor DC66P 12V/24V Monoblock Direct Current Motor Reversing Contactor
  • DELIXI CJX2H-Z DC Control Contactor DELIXI CJX2H-Z DC Control Contactor
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...

    Request a Quote 0 WhatsApp

    SHANGHAI NEWTREND ELECTRIC

    Your quote request

    Select products, add quantities and tell us what you need.

    You can send a general enquiry, or browse our products and add items to this list.

    We use your details to respond to this enquiry. Privacy policy

    Continue browsing