People Electric · AC Contactor
Product overview
Original People Electric CJX2-09-95 contactors provide remote switching of AC circuits. Select against the stated utilization category and actual main-circuit voltage. An appropriately selected overload relay and short-circuit protective device are required where the application calls for protection.
Technical selection summary
| Manufacturer / series | Original People Electric CJX2-09-95 |
|---|---|
| Rated current reference | 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A |
| Main poles | 3P; normal non-reversing version on this page |
| Main-circuit operating voltage | Up to 690V; current buttons refer to AC-3 at 380V |
| Rated insulation voltage | 690V |
| Auxiliary contacts | 9–32A: 1NO or 1NC; 40–95A: 1NO+1NC |
| Coil control voltage | AC 36, 110, 220 or 380V in technical table 2 |
| Standards stated | GB 14048.4; IEC 60947-4-1 |
| Ambient / altitude | -5 to +40°C, daily average ≤35°C; altitude ≤2,000m |
| Installation | Pollution degree 3; category III; tilt ≤5° |
| CJX2-09 motor reference | AC-3 at 380V: 9A, 4kW |
| CJX2-12 motor reference | AC-3 at 380V: 12A, 5.5kW |
| CJX2-18 motor reference | AC-3 at 380V: 18A, 7.5kW |
| CJX2-25 motor reference | AC-3 at 380V: 25A, 11kW |
| CJX2-32 motor reference | AC-3 at 380V: 32A, 15kW |
| CJX2-40 motor reference | AC-3 at 380V: 40A, 18.5kW |
| CJX2-50 motor reference | AC-3 at 380V: 50A, 22kW |
| CJX2-65 motor reference | AC-3 at 380V: 65A, 30kW |
| CJX2-80 motor reference | AC-3 at 380V: 80A, 37kW |
| CJX2-95 motor reference | AC-3 at 380V: 95A, 45kW |
Current choices are AC-3 at 380V. This page covers normal 3-pole contactors. 4-pole, reversing, timer and accessory assemblies require separate confirmation. Only the four coil voltages present in technical table 2 are selectable; 48V and 127V appear only in the ordering notice and are not opened here. Photographs illustrate the original series and can show different frames or auxiliary arrangements.
Typical applications
- Remote switching in industrial control and distribution circuits within the documented duty ratings.
- Motor or load control with correctly coordinated protection and accessories.
Specify your enquiry
For a focused quotation, include:
- Rated current, actual main-circuit voltage and utilization category.
- Main and auxiliary contacts; exact coil voltage, AC/DC supply and frequency.
- Quantity, mounting arrangement, required accessories and destination.
Download People Electric CJX2-09-95 catalogue (PDF)