NewTrend · Tmax T Series · Molded-Case Circuit Breakers
Product overview
NewTrend Tmax T-series molded-case circuit breakers cover compact branch protection, industrial feeders, generator circuits and main distribution. The range includes T1, T2, T3, T4, T5, T6 and T7, with the T7M stored-energy operating version for motorized applications.
Thermal-magnetic and electronic releases provide different protection and adjustment capabilities. Match the rated current, frame, pole count, release and installation version to the application. The product photographs show our NewTrend units; the T3N 250A shown is one version within the range.
Technical selection summary
| Parameter | Specification |
|---|---|
| Brand | NewTrend |
| Series | Tmax T1–T7 / T7M; traditional T generation |
| Rated current | 1.6–1600A across the selectable AC distribution configurations; exact ratings depend on frame and release |
| Poles | T1 single-pole branch: 1P; standard T1–T7/T7M: 3P or 4P |
| Main-circuit voltage | 3P/4P AC versions: up to 690V, 50/60Hz; T1 1P: up to 240V AC |
| Breaking capacity | 16–200kA at AC380/400/415V, depending on frame and performance level; T1 1P is specified separately at AC220/230V |
| Protection | Thermal-magnetic, generator protection, or electronic LS/I, LSI, LSIG and LSIRc versions as listed |
| Construction | Fixed; selected frames also plug-in or withdrawable |
| Manufacturer | Shanghai Newtrend Electric Co., Ltd. |
Frame and release selection
| Frame | Poles | Thermal-magnetic / generator versions | Electronic versions | Installation |
|---|---|---|---|---|
| T1 160 | 1P | TMF: 16–160A | — | Fixed |
| T1 160 | 3P / 4P | TMD: 16–160A; N starts at 32A, C at 25A | — | Fixed |
| T2 160 | 3P / 4P | TMD: 1.6–160A; TMG: 25–160A | PR221DS: 10/25/63/100/160A; PR221GP: 63/100/160A | Fixed / plug-in |
| T3 250 | 3P / 4P | TMD / TMG: 63–250A | — | Fixed / plug-in |
| T4 250 / 320 | 3P / 4P | TMD: 20/32/50A; TMA: 80–250A | PR221DS, PR222DS/P, PR222DS/PD: 100/160/250/320A; PR223DS: 160/250/320A, within frame rating | Fixed / plug-in / withdrawable |
| T5 400 / 630 | 3P / 4P | TMA / TMG: 320/400/500A, within frame rating | PR221DS / PR222DS/P / PR222DS/PD / PR223DS: 320/400/630A, within frame rating | Fixed / plug-in / withdrawable |
| T6 630 / 800 / 1000 | 3P / 4P | TMA: 630/800A | PR221DS / PR222DS/P / PR222DS/PD / PR223DS: 630/800/1000A, within frame rating | Fixed; withdrawable on 630/800A frames |
| T7 / T7M 800 / 1000 / 1250 / 1600 | 3P / 4P | — | PR231/P, PR232/P, PR331/P, PR332/P; rating plugs 400/630/800/1000/1250/1600A within sensor/frame limit | Fixed / withdrawable |
Frame current is the upper frame rating; the installed release or rating plug defines In. Thermal-magnetic releases use listed discrete ratings, not every intermediate ampere value. Plug-in T2/T3/T5 630 and withdrawable T5 630 require current derating for the installation conditions. T7M denotes the stored-energy mechanism; the charging motor, opening/closing releases and control supply must be specified with the assembly.
Breaking capacity by frame
| Frame / grade | Icu at 380/400/415V AC | Ics at 380/400/415V AC | Voltage / version condition |
|---|---|---|---|
| T1 B / C / N | 16 / 25 / 36kA | 100 / 100 / 75% Icu | 3P / 4P |
| T2 N / S / H / L | 36 / 50 / 70 / 85kA | 100 / 100 / 100%; L: 70kA | 3P / 4P |
| T3 N / S | 36 / 50kA | 75%; S: 27kA | 3P / 4P |
| T4 N / S / H / L / V | 36 / 50 / 70 / 120 / 200kA | 100% Icu | Do not apply these values at 690V |
| T5 N / S / H / L / V | 36 / 50 / 70 / 120 / 200kA | 100% Icu | Do not apply these values at 690V |
| T6 N / S / H / L | 36 / 50 / 70 / 100kA | 100 / 100 / 100 / 75% Icu | T6 V is a separate special version |
| T7 / T7M S / H / L / V | 50 / 70 / 120 / 150kA | 100% Icu | V: 800/1000/1250A frames; not 1600A |
| T1 B single-pole | Not rated at 380–415V | At 220/230V: 75% Icu | Icu at 220/230V: 16kA for 16/20A; 25kA for higher ratings |
Protection functions
| Release | Functions / application |
|---|---|
| TMF | Fixed thermal and magnetic thresholds; T1 single-pole |
| TMD | Adjustable overload threshold, fixed instantaneous magnetic threshold |
| TMA | Adjustable thermal and magnetic thresholds |
| TMG / PR221GP | Lower short-circuit trip thresholds for generator and long-cable protection |
| PR221DS-LS/I / PR231/P-LS/I | L overload protection with selectable delayed S or instantaneous I short-circuit protection |
| PR222DS/P / PR222DS/PD | LSI or LSIG; PD versions support communication with the required equipment |
| PR223DS | Electronic protection with measurement/communication capability and required accessories |
| PR232/P | LSI protection |
| PR331/P | LSIG protection |
| PR332/P | LI / LSI / LSIG / LSIRc; residual-current protection requires the matching external toroid |
Dimensions — fixed breaker body
| Frame | 1P width | 3P width | 4P width | Height | Depth |
|---|---|---|---|---|---|
| T1 | 25.4 mm | 76 mm | 102 mm | 130 mm | 70 mm |
| T2 | — | 90 mm | 120 mm | 130 mm | 70 mm |
| T3 | — | 105 mm | 140 mm | 150 mm | 70 mm |
| T4 | — | 105 mm | 140 mm | 205 mm | 103.5 mm |
| T5 | — | 140 mm | 186 mm | 205 mm | 103.5 mm |
| T6 | — | 210 mm | 280 mm | 268 mm | 103.5 mm |
| T7 — manual | — | 210 mm | 280 mm | 268 mm | 154 mm |
| T7M — stored energy | — | 210 mm | 280 mm | 268 mm | 178 mm |
Dimensions are for the basic fixed body. Terminal covers, extended/spread terminals, rotary handles, motor operators and plug-in/withdrawable bases change the installation envelope. Use the drawing for the exact assembled version before machining the panel.
Special-purpose T-series configurations
| Configuration | Applicable frames | Selection boundary |
|---|---|---|
| Motor short-circuit protection | T2 / T3 / T4 magnetic-only; T2/T4/T5/T6 PR221DS-I; T7 PR231/P-I | Three-pole motor versions; coordinate with overload protection and contactor |
| Integrated motor protection | T2 PR221MP; T4/T5/T6 PR222MP | Select motor current, starting duty and trip class for the exact version |
| Zone selectivity | T4/T5/T6 PR223EF; T7 PR332/P | Match compatible upstream/downstream devices and interconnection |
| High-voltage AC | T4/T5 up to 1150V; T6 up to 1000V | Dedicated voltage-rated assemblies; standard 415V Icu values do not apply |
| 1000V DC | T4V / T5V / T6L, four poles in series | Dedicated thermomagnetic versions, prescribed series wiring and supply direction |
| Switch-disconnectors | T1D / T3D / T4D / T5D / T6D / T7D | Isolation/switching devices without overcurrent trip protection; separate selection from MCCBs |
Special-purpose versions require their dedicated release, wiring and assembly specification. The selectors on this page cover standard AC distribution and generator configurations.
Installation and accessories
Specify fixed, plug-in or withdrawable construction, front or rear terminals, direct or extended rotary handle, auxiliary contacts, shunt opening release, undervoltage release and motor control as required. Accessory control voltages and compatibility depend on the exact frame. Isolate the supply before installation or servicing; electrical work must be carried out by qualified personnel.
Typical applications
- Main and outgoing feeders in industrial distribution panels.
- Commercial building distribution and equipment protection.
- Generator and long-cable circuits using the matching TMG or PR221GP release.
- Selective distribution with coordinated electronic protection.