People Electric · Travel Limit Switch
Product overview
People Electric HL travel switches detect mechanical movement for stroke, direction or speed-change control circuits. Six documented actuator configurations cover roller arms, an adjustable rod, plungers and a spring rod. Match actuator geometry and travel to the machine, then confirm the exact contact arrangement and electrical load.
Technical selection summary
| Manufacturer / series | Original People Electric HL |
|---|---|
| Actuator models | HL-5000 roller rotating arm; HL-5030 adjustable roller arm; HL-5050 adjustable rotating rod; HL-5100 direct plunger; HL-5200 roller plunger; HL-5300 universal spring rod |
| Rated control duties | AC-15: AC380V / 2A, 50Hz; DC-13: DC220V / 0.4A |
| Conventional thermal current / insulation | Ith 5A; Ui 500V |
| Protection class stated | IP66 |
| Electrical / mechanical life | 500,000 electrical operations; 2,000,000 mechanical operations |
| Operating frequency | 120 operations/minute as stated |
| Operating forces | HL-5000/5030/5050/5100 ≤7.4N; HL-5200 ≤8.8N; HL-5300 ≤1.5N |
| Reset forces | HL-5000/5030/5050 ≥1N; HL-5100/5200 ≥2N; HL-5300 ≥0.3N |
| Travel | HL-5000/5030/5050 operating angle 22.5°, overtravel ≥75°, total ≥95°; HL-5300 22.5°, ≥20°, ≥50°. Plunger types show operating travel 2, overtravel ≥4 and total ≥5.8; confirm linear units with the dimensional drawing. |
| Mounting reference | Body width 33mm, depth 34mm and main mounting centres 24 × 50mm in the original drawings; head dimensions vary by actuator |
| Environment | Altitude <2,000m; -5 to +40°C, daily average ≤35°C; RH ≤50% at +40°C; pollution degree III; installation category III |
| Standards stated by manufacturer | GB 14048.5; IEC 60947-5-1 |
Actuator selection does not replace checking the complete ordered contact configuration, operating direction and mounting drawing. Confirm contact arrangement, required switching duty, travel and installation conditions before ordering; Ith 5A is distinct from the AC-15/DC-13 operating-current ratings.
Typical applications
- Mechanical end-position and stroke detection on industrial equipment.
- Machine control for direction or speed changes using an appropriate actuator and control circuit.
Specify your enquiry
For a focused quotation, include:
- Required HL actuator model and contact arrangement, with replacement nameplate/photo if available.
- Control voltage/load, actuation direction, available travel and mounting clearance.
- Environmental requirements, cable entry, quantity and destination.
Download People Electric HL catalogue (PDF)