Product overview
The CHINT NQ3-11P combines a contactor and matched thermal overload relay for direct-on-line motor starting and stopping. Select the relay setting range from motor nameplate current, then match the control-coil supply.
Technical selection summary
| Exact model | NQ3-11P; button-equipped construction |
|---|---|
| Contactor / thermal relay | NC1-3210 and NR2-25 in the manufacturer assembly table |
| Thermal relay selection | Available relay ranges on this page: 1–1.6 A through 17–25 A; select the matching manufacturer relay code |
| 380/400 V AC-3 reference | Up to 11 kW at the 17–25 A relay range; manufacturer operational current 22 A, not an unrestricted 25 A load rating |
| Control-coil options on this page | AC 36, 110, 220 or 380 V; match frequency and complete unit marking |
| Protection / enclosure | Thermal overload and phase-failure protection; coordinate separate short-circuit protection. IP55 manufacturer enclosure reference |
| Standard reference | IEC/EN 60947-4-1; use the exact motor-voltage and relay row |
Motor kW depends on voltage and relay range. A setting-range upper value is not a universal starter operational current. Confirm load current, start duty, main/control wiring, enclosure and protection coordination.
Typical applications
- Distribution and control assemblies matched to the specified device
- Replacement procurement using the complete CHINT model
Product reference images and drawings
Use the applicable manufacturer model row, connection and outline drawing. Retained family references may show other versions.