LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
  • Home
  • Products
    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Automation & Control

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Circuit Breaker & Fuses

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Din-Rail Mounted Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Distribution Box & Cabinet

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Load Center & Meter Bases

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Solar PV Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Electrical Accessories

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
Search
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
Click to enlarge
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
Home Electrical Accessories Others LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
SW150 to SW800 1P 1NO Electric Vehicle DC Contactor
SW150 to SW800 1P 1NO Electric Vehicle DC Contactor
Back to products
SW205 250A/400A SPDT Motor Reversing DC Contactor
SW205 250A/400A SPDT Motor Reversing DC Contactor

LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC2K06
Phase:3
Main Circuit Rating Current:6A
type:Reversing contactor
Certificate:CE, ROHS
Number of Pole
Main Circuit Rating Voltage
SKU: 62022411598 Category: Others
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

LC2K06 Contactor 3P LC2K0610 LC2K0610B7 LC2K0610M7 LC2K0610P7 LC2K0601 LC2K0601B7 LC2K0601M7 LC2K0601P7 6A Reversing Contactor

 

LC2K and LP2K series is a complete range of compact mini style reversing contactors with common options available for ratings 6A, 9A, 12A, and 16 A. The offer includes a variety of different terminal connection choices and a wide range of coil voltage options. Compliance with standards: IEC 60947, VDE 0660, BS 5424, CE, etc.

  • Available control circuits: AC, DC
  • Applications: 2.2 kW, 4.5 kW, 5.5 kW in AC3 and AC4
  • Terminal connection types include: 
    – Screw clamp 
    – Faston connectors 
    – Spring terminals 
    – Pins for printed circuit boards
  • 1 NO or 1NC contact embedded
  • Available for 1 way motors, 2 way motors (reversing Contactors) and Star Delta pre- wired version
  • Includes full range of control relays in the same design
  • Possibility to extend the amount of auxiliary contacts thanks to additional auxiliary contact blocks
  • Possibility to protect the motor thanks to additional thermal relays LR2K
Model Number LC2K06 LC2K09 LC2K12 LC2K16 LP2K06 LP2K09 LP2K12 LP2K16
Rated operational current (AC-3, 380V) 6A 9A 12A 16A 6A 9A 12A 16A
Rated operational current (AC-3, 660V) 5A 7.5A 10A 12A 5A 7.5A 10A 12A
Coil voltage
(Control circuit voltage) 

AC 
12V 24V 48V 110V 220V

230V 240V 380V 415V

DC
12V 24V 48V 100V 110V

220V 230V 240V 250V

Rated operational voltage 380V, 660V
Rated insulation voltage 690V
Main and auxiliary contacts 3P+NO, 3P+NC, 2NO+2NC
Motor power (AC-3, 220/240V) 1.5KW 2.2KW 3KW 3KW 1.5KW 2.2KW 3KW 3KW
Motor power (AC-3, 380/415V) 2.2KW 4KW 5.5KW 7.5KW 2.2KW 4KW 5.5KW 7.5KW
Motor power (AC-3, 440V) 3KW 4KW 5.5KW 7.5KW 3KW 4KW 5.5KW 7.5KW
Motor power (AC-3, 500/660/690V) 3KW 4KW 4KW 4KW 3KW 4KW 4KW 4KW
Mouting type DIN Rail / PCB Solder Pin / Plate
Coil Pull-In Voltage 0.85-1.1 Us
Coil Drop-Out Voltage 0.2-0.75 Us ≤0.2 Us
Coil power Pull-In 40VA, Maintain 4VA
Coil power consumption 1.2W
Coil Pull-In time 6-18 ms
Coil Drop-Out time 5-12 ms
Electrical life 500 thousand times
Mechanical life 100 thousand times
Ambient air temperature -5…40 °C
Operating altitude 2000 m without derating in temperature

 

 

Standard control coil voltage CODE: 

LC2K (AC voltage coil)
Volts
(50/60Hz)
12 20 24 36 42 48 110 115 120 127 200/
208
220/
230
230 230/
240
256 277 380/
400
Code J7 Z7 B7 C7 D7 E7 F7 FE7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7
Volts
(50/60Hz)
400 400/
415
440 480 500 575 600 660/
690
                 
Code V7 N7 R7 T7 S7 SC7 X7 Y7                  
LP2K (DC voltage coil)      
Volts 12 20 24 36 48 60 72 100 110 125 155 174 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD

 

Example of complete model number:

LP2K09105BD:   
  LP2K means DC coil reversing contactor, LC2K means AC coil reversing contactor
  09 means AC-3 9A rated current
  10 means NO auxiliary contact, 01 means NC auxiliary contact
  5 means PCB Solder Pin type, without 5 means regular DIN Rail type
  BD means the coil voltage code

 

Dimension for DIN Rail mounting:

 

Dimension for Plate mounting:

 

Dimension for PCB Solder Pin mounting:

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Number of Pole

3

Main Circuit Rating Voltage

AC or DC

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC66P
Phase:1
Main Circuit Rating Current:200A
Sold out
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:GC, iCT
Phase:1
Main Circuit Rating Current:12A ~ 100A
750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
LC1D25 3P 25A AC Contactor 24V-240V Coil Options
LC1D25 3P 25A AC Contactor 24V-240V Coil Options

LC1D25 3P 25A AC Contactor 24V-240V Coil Options

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:25A
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor
LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

LP1K09105SD/09015SD 3P 9A 72VDC Coil Solder Pin Mini Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K09
Phase:3
Main Circuit Rating Current:9A
Sold out
THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker
THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker

THQL1115 1-Pole 15A 120V/240V Q-Line Plug-in Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,380V
LC1-F 3P 225A DC Coil Contactor 24Vdc-440Vdc

LC1-F 3P 225A DC Coil Contactor 24Vdc-440Vdc

Electricity Type:DC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1F225
Phase:3
Main Circuit Rating Current:225A
Sold out
THQL1125 1-Pole 25A 120V/240V Q-Line Plug-in Circuit Breaker
THQL1125 1-Pole 25A 120V/240V Q-Line Plug-in Circuit Breaker

THQL1125 1-Pole 25A 120V/240V Q-Line Plug-in Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSIG
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,380V
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • CHINT NP6 Push Button CHINT NP6 Push Button
  • 2P 500V 1000V Solar PV Moulded Case Circuit Breaker 125A-250A 2P 500V 1000V Solar PV Moulded Case Circuit Breaker 125A-250A
  • Swimming Pool Heat Pump 1-Phase Mini AC Contactor 2.5kW-5.5kW Swimming Pool Heat Pump 1-Phase Mini AC Contactor 2.5kW-5.5kW
  • CHINT NJR5-ZX4 460V Online Soft Starter 30kW to 400kW CHINT NJR5-ZX4 460V Online Soft Starter 30kW to 400kW
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the plane.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...