Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
Search
Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
Click to enlarge
Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
Home Circuit Breaker & Fuses MCCB Circuit Breaker Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
DELIXI CJX2s-0901 to CJX2s-6511 AC Magnetic Contactor
DELIXI CJX2s-0901 to CJX2s-6511 AC Magnetic Contactor
Back to products
Meter Socket Sealing Lock Ring
Meter Socket Sealing Lock Ring

Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:T4S T4H T4L T4V
Rated Frequency (Hz):50/60Hz
Breaking Capacity:50kA, 70kA, 120kA
Rated Voltage:690V
Type:Moulded Case
Poles Number:3
SKU: 1769740503022051328 Category: MCCB Circuit Breaker
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Tmax T4S T4H T4L T4V 250 3P 4P 125A 160A 200A 250A TMA PR221DS-LS/I 690V 1000V 1150V MCCB Molded Case Circuit Breaker

 

Tmax Molded Case Circuit breaker is now available as a complete range of up to 1600 A.

 –  Manually operated or Electrically operated.

 –  All available in the Fixed version; T4 and T5 has Plug-in version; T4, T5, T6 and T7 has Withdrawable version as well. 

 –  With the same frame size, the circuit-breakers are available with different breaking capacities and different rated currents.

 –  IEC or UL standards

   

 

 

 

 

 

 

 

 

Additional information
Weight 4 kg
Dimensions 35 × 35 × 35 cm
Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Trip Unit Protection

How to choose between Thermal-Magnetic (TMD) and Electronic (Micrologic) trip units?

A

Thermal-magnetic trip units provide fixed or adjustable bimetallic overload and electromagnetic instantaneous short-circuit protection, ideal for standard industrial power distribution. Electronic microprocessor trip units offer precise digital dials for L (Long-time delay overload), S (Short-time delay short-circuit), I (Instantaneous short-circuit), and G (Ground-fault protection), delivering total time-current selectivity in modern switchgear.

Ics vs Icu Capacity

What is the technical distinction between Ultimate (Icu) and Service (Ics) breaking capacity?

A

Icu represents the absolute maximum fault current the breaker can safely interrupt, after which inspection or replacement may be needed. Ics represents the operational breaking capacity (50%, 75%, or 100% of Icu) that the breaker can clear repeatedly and remain fully operational without performance degradation. In critical healthcare, data center, and continuous industrial applications, specify breakers with Ics = 100% Icu.

3P vs 4P Neutral

When should a 4-Pole (4P) MCCB be specified instead of a standard 3-Pole (3P) MCCB?

A

A 4P breaker with a switched neutral is required in systems with dual power sources (generator / utility ATS transfer) to prevent circulating neutral currents, in IT distribution networks, and in commercial installations with heavy non-linear harmonic loads (LED drivers, variable speed drives) where neutral conductor current can exceed phase currents.

Motorized & Remote Operation

How to select manual rotary handles vs motorized electric operating mechanisms?

A

Direct or extended door rotary handles are specified when the MCCB is enclosed inside switchgear cubicles, providing padlocking and door-interlock safety. Motor operating mechanisms (electric operators) are required for automated SCADA control, remote PLC open/close operations, and automatic transfer switch (ATS) integration.

Terminal & Mounting Options

What terminal connection hardware and mounting configurations are available?

A

Standard front connection lugs accept copper or aluminum compression terminals and busbar connections. For high-density panel boards, extended spreader terminals, rear connection studs, and plug-in / draw-out base cassettes are available to facilitate rapid maintenance and modular swap-out.

Related products

Sold out
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB

29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB

Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:29450
Sold out
Tmax T3N 3P/4P MCCB 125A-250A 50kA TMD

Tmax T3N 3P/4P MCCB 125A-250A 50kA TMD

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:T3N
Rated Frequency (Hz):50/60Hz
Breaking Capacity:36kA 50kA 70kA 100A
Rated Voltage:690V
Pole:3Pole, 4Pole
Breaking Capacity at 415V:50kA
Rated Current:63A ~ 250A
Trip Unit:Thermal-Magnetic
Type:Moulded Case
NF-SS series MCCB

NF-SS series MCCB

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:NF-CS
Breaking Capacity:10-50kA
Rated Voltage:max to 690V
Type:Moulded Case
Sold out
Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A
Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A

Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:Sace-Tmax
Breaking Capacity:35kA,50kA,65kA
Rated Voltage:380V
Type:Moulded Case
Tmax T5 MCCB 3P 400A-630A PR221DS-LS/I Adjustable
Tmax T5 MCCB 3P 400A-630A PR221DS-LS/I Adjustable

Tmax T5 MCCB 3P 400A-630A PR221DS-LS/I Adjustable

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:T5N PR221DS-LS/I
Breaking Capacity:36kA, 50kA, 70kA, 120kA, 200kA
Rated Voltage:690V
Trip Unit:PR221DS-LS/I Electronic
Type:Moulded Case
Poles Number:3
Tmax T7S/T7H/T7L 3P MCCB 1000A-1600A PR231/P LSI

Tmax T7S/T7H/T7L 3P MCCB 1000A-1600A PR231/P LSI

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:T7S PR231/P LS/I
Rated Frequency (Hz):50/60Hz
Breaking Capacity:50kA, 70kA, 120kA
Rated Voltage:690V
Trip Unit:PR231/P LS/I Electronic
Type:Moulded Case
Poles Number:3
SACE S7 3P 1250A 1600A Molded Case Circuit Breaker
SACE S7 3P 1250A 1600A Molded Case Circuit Breaker

SACE S7 3P 1250A 1600A Molded Case Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:Sace S7S
Breaking Capacity:50kA,65kA
Rated Voltage:600V
Current (In):1600A
Type:Moulded Case
Poles Number:3
Sold out
Compact NS Series Molded Case Circuit Breaker 3P/4P
Compact NS Series Molded Case Circuit Breaker 3P/4P

Compact NS Series Molded Case Circuit Breaker 3P/4P

Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:NS
Breaking Capacity:35kA,50kA
Rated Voltage:380v
Type:Moulded Case
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Tmax T6N 3P/4P MCCB 630A/800A PR221DS Adjustable Tmax T6N 3P/4P MCCB 630A/800A PR221DS Adjustable
  • Tmax T3N 3P/4P MCCB 125A-250A 50kA TMD Tmax T3N 3P/4P MCCB 125A-250A 50kA TMD
  • Tmax T4S/T4H/T4L 3P/4P MCCB 250A/320A TMA Tmax T4S/T4H/T4L 3P/4P MCCB 250A/320A TMA
  • 29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB 29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the star.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...