People Electric · Autotransformer Motor Starter
Product overview
People Electric XJ01 starting boxes use an autotransformer to reduce the voltage applied during infrequent motor starts. The enclosed assembly incorporates contactors, a thermal relay and a time relay. Match the documented starter size to the motor nameplate, load characteristics and permitted starting duty.
Technical selection summary
| Manufacturer / series | Original People Electric XJ01 |
|---|---|
| Supply / motor | Three-phase AC380V, 50Hz; squirrel-cage induction motor |
| Documented models / maximum motor power | XJ01-14: 14kW; XJ01-17: 17kW; XJ01-22: 22kW; XJ01-30: 30kW; XJ01-40: 40kW; XJ01-55: 55kW; XJ01-75: 75kW; XJ01-90: 90kW; XJ01-100: 100kW; XJ01-115: 115kW; XJ01-135: 135kW; XJ01-155: 155kW; XJ01-190: 190kW; XJ01-225: 225kW; XJ01-260: 260kW; XJ01-300: 300kW |
| Maximum operating current by model | XJ01-14: 28A; XJ01-17: 34A; XJ01-22: 43A; XJ01-30: 58A; XJ01-40: 77A; XJ01-55: 110A; XJ01-75: 142A; XJ01-90: 170A; XJ01-100: 190A; XJ01-115: 218A; XJ01-135: 256A; XJ01-155: 300A; XJ01-190: 350A; XJ01-225: 410A; XJ01-260: 480A; XJ01-300: 530A |
| Starting taps | 65% and 80% of rated voltage; source default is 65%. Confirm the required connection and motor starting torque. |
| Starting time | Time relay adjustment 1–15s; set for the actual load |
| Operation | Automatic operation is described for smaller models; manual and automatic operation for 90kW and above. Confirm the exact controls supplied, particularly the 75kW boundary. |
| Protection / assembly | Autotransformer, contactors, thermal relay and time relay in an enclosure; confirm overload setting and upstream short-circuit protection |
| Overall size, W × H × D | 14–30kW: 400 × 700 × 280mm; 40–75kW: 500 × 1000 × 310mm; 90–115kW: 550 × 1260 × 420mm; 135–190kW: 610 × 1440 × 490mm; 225–300kW: 700 × 1700 × 590mm |
| Mounting centres E × F | 14–30kW: 370 × 120mm; 40–75kW: 470 × 230mm; 90–115kW: 490 × 280mm; 135–190kW: 560 × 325mm; 225–300kW: 645 × 410mm. Source tolerance ±5mm; holes 10mm except 225–300kW 12mm. |
| Environment | Indoor; altitude <2,000m; -5 to +40°C, daily average ≤35°C; RH ≤50% at +40°C; pollution class III; mounting inclination ≤5° |
| Standards stated by manufacturer | GB 14048.4; IEC 60947 |
Selection is limited to the 14–300kW models explicitly tabulated in the manufacturer catalogue. The introductory 400kW upper range is not added as an undocumented option. Confirm actual motor current, start duration/frequency, tap selection, thermal-relay/CT coordination and the complete supplied configuration before order.
Typical applications
- Reduced-voltage starting of three-phase industrial squirrel-cage motors.
- Infrequent motor starts where an enclosed autotransformer starter matches the load and supply.
Specify your enquiry
For a focused quotation, include:
- Selected XJ01 power, motor nameplate current, AC380V/50Hz supply and load type.
- Starting time, starts per hour, required 65%/80% tap and manual/automatic controls.
- Overload setting, upstream protective device, enclosure requirements, quantity and destination.
Download People Electric XJ01 catalogue (PDF)