People Electric · Amorphous Alloy Dry Type Transformer
Product overview
People Electric SCBH15 combines an amorphous-alloy core with resin-cast windings for dry-type distribution service. Select the capacity and matching short-circuit impedance from the manufacturer technical schedule. Natural-air/forced-air cooling arrangements and the approved thermal design are confirmed for the installation.
Technical selection summary
| Manufacturer / series | Original People Electric SCBH15 |
|---|---|
| Construction | Three-phase; amorphous-alloy core; resin-cast dry type |
| Published voltage / frequency configuration | Primary10kV; secondary0.4kV;50Hz |
| Connection group | Dyn11 |
| Primary tapping | ±2×2.5% for the published10kV configuration |
| Cooling | AN/AF; confirm equipment and continuous rating for the specified cooling arrangement |
| 4% impedance capacities | 30, 50, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630kVA |
| 6% impedance capacities | 630, 800, 1000, 1250, 1600, 2000, 2500kVA |
| 8% impedance capacities | 1600, 2000, 2500kVA |
| No-load loss | 70W at30kVA;630kVA:420W at4% or410W at6%;2500kVA:1200W at6% or8%; see the complete table for other capacities |
| Load-loss reference temperatures | Manufacturer table gives separate100°C(B),120°C(F) and145°C(H) values; the agreed insulation/thermal design determines the applicable column |
| Installation | Indoor; altitude≤1000m; ambient maximum+40°C; specify actual site conditions |
| Dimensions / accessories | Confirm enclosure protection, cooling fans, temperature monitoring, terminal arrangement and approved general arrangement |
Capacity and impedance are linked. The cooling and load-loss temperature columns are technical references, not an unconditional overload rating or an assertion that every thermal design is interchangeable. Confirm the insulation class, guaranteed losses, enclosure, cooling equipment and final dimensions for the ordered configuration.
Typical applications
- Compatible indoor10kV/0.4kV distribution installations requiring dry-type amorphous-core transformers.
Specify your enquiry
For a focused quotation, include:
- Capacity, selected impedance,10/0.4kV50Hz Dyn11 confirmation and primary tapping.
- Insulation/temperature-rise class, guaranteed losses, AN/AF cooling equipment and enclosure protection.
- Site conditions, installation drawing/clearances, accessories, quantity and destination.
Download People Electric SCBH15 catalogue (PDF)
People Electric transformer selection handbook (2023 edition, PDF)
People Electric transformer sales handbook (PDF)