People Electric JRS8 Thermal Overload Relay, 0.1–500A People Electric JRS8 Thermal Overload Relay, 0.1–500A
  • Home
  • Products
    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Automation & Control

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Circuit Breaker & Fuses

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Din-Rail Mounted Products

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Distribution Box & Cabinet

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Load Center & Meter Bases

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Solar PV Products

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Electrical Accessories

    QO2100 2-Pole 100-Amp Type QO Circuit Breaker 10kAIC

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
People Electric JRS8 Thermal Overload Relay, 0.1–500A People Electric JRS8 Thermal Overload Relay, 0.1–500A
Search
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
Click to enlarge
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
People Electric JRS8 Thermal Overload Relay, 0.1–500A
Home Electrical Accessories Others People Electrical Materials People Electric JRS8 Thermal Overload Relay, 0.1–500A
DC88P 500A 12V/24V DC Reversing Contactor Warn Badlands Replacement
DC88P 500A 12V/24V DC Reversing Contactor Warn Badlands Replacement
Back to products
NewTrend W100-T-P-DE 500A Short-Time Reversing DC Contactor
NewTrend W100-T-P-DE 500A Short-Time Reversing DC Contactor

People Electric JRS8 Thermal Overload Relay, 0.1–500A

Original People Electric JRS8 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.

Model
Frame
Current Setting Range
Installation Code
Request a Quote

Send quantities and requirements together. Availability and final specifications are confirmed with your quotation.

SKU: JRS8 Categories: People Contactor & Overload Relays, People Electrical Materials, People Relays Brand: People Electric
  • Description
  • Additional information
  • Technical Documents
  • Selection & Ordering
Description

People Electric · Thermal Overload Relay

Product overview

Original People Electric JRS8 thermal overload relays protect AC motors against sustained overload and phase loss. The setting range must contain the motor rated current and match the relay frame. Use with the correctly matched switching device and separately coordinated short-circuit protection.

Technical selection summary

Manufacturer / seriesOriginal People Electric JRS8
Product functionThermal motor overload and phase-loss protection; use a separately coordinated short-circuit protective device
Main-circuit operating voltageAC 660V
Main-circuit frequency50/60Hz
Trip classClass 10A: JRS8-16, -25, -45. Class 10: -85, -105, -170, -250, -370.
Auxiliary circuitFrame-dependent auxiliary contact arrangements and ratings; refer to original table 4 and confirm the required NC trip and NO indication circuits.
Setting selectionChoose a frame first, then one documented adjustment interval for that frame. Set the relay to the actual motor/load current.
Control supplyThermal bimetal relay; no independent contactor-coil voltage option is specified on this page. Auxiliary-circuit voltage ratings are contact-switching ratings.
Protection coordinationThis relay is not a short-circuit circuit breaker. Fuse/SCPD references and conductor recommendations are in the complete catalogue.
Ambient / altitude-5 to +40°C, daily average ≤35°C; altitude ≤2,000m
Installation environmentPollution degree 3; installation category III; normal mounting within ±5° without excessive impact or vibration
Standards statedGB 14048.4; IEC 60947-4-1
JRS8-16 adjustment intervals0.11–0.16A, 0.14–0.21A, 0.19–0.29A, 0.27–0.4A, 0.35–0.52A, 0.42–0.63A, 0.55–0.83A, 0.7–1A, 0.9–1.3A, 1.1–1.5A, 1.3–1.8A, 1.5–2.1A, 1.7–2.4A, 2.1–3A, 2.7–4A, 3.4–4.5A, 4–6A, 5.2–7.5A, 6.3–9A, 7.5–11A, 9–13A, 12–17.6A
JRS8-25 adjustment intervals0.1–0.16A, 0.16–0.25A, 0.25–0.4A, 0.4–0.63A, 0.63–1A, 1–1.4A, 1.3–1.8A, 1.7–2.4A, 2.2–3.1A, 2.8–4A, 3.5–5A, 4.5–6.5A, 6–8.5A, 7.5–11A, 10–14A, 13–19A, 18–25A, 24–32A
JRS8-45 adjustment intervals0.28–0.4A, 0.35–0.52A, 0.45–0.63A, 0.55–0.83A, 0.7–1A, 0.86–1.3A, 1.1–1.6A, 1.4–2.1A, 1.8–2.5A, 2.2–3.3A, 2.8–4A, 3.5–5.2A, 4.5–6.3A, 5.5–8.3A, 7–10A, 8.6–13A, 11–16A, 14–21A, 18–27A, 25–35A, 30–45A
JRS8-85 adjustment intervals6–10A, 8–14A, 12–20A, 17–29A, 25–40A, 35–55A, 45–70A, 60–110A
JRS8-105 adjustment intervals27–42A, 36–52A, 45–63A, 57–82A, 70–105A, 80–115A
JRS8-170 adjustment intervals90–130A, 110–160A, 140–200A
JRS8-250 adjustment intervals100–160A, 160–250A, 250–400A
JRS8-370 adjustment intervals100–160A, 160–250A, 250–400A, 310–500A
Installation codesZ = combined installation; F = separate installation

Frame codes are catalogue frame designations, not limits to substitute for the documented setting intervals. Some printed ranges extend beyond the frame-code number. Z is combined installation; F is separate installation. Confirm exact contactor fit and auxiliary-contact requirements; do not assume every frame has identical contacts. Product photographs are original series illustrations and can show other frames or installation versions.

Typical applications

  • Thermal overload and phase-loss protection of AC motor circuits.
  • Motor-starter control circuits using the correctly matched contactor and coordinated short-circuit protection.

Specify your enquiry

For a focused quotation, include:

  • Relay frame and current setting range; motor current, power and actual main-circuit voltage.
  • Required installation version, matching contactor, reset mode and auxiliary-contact requirements.
  • Quantity, destination and required drawings or compliance documents.

Download People Electric JRS8 catalogue (PDF)

Product reference images and drawings

People Electric JRS8 technical-1

People Electric JRS8 technical-2

People Electric JRS8 technical-3

People Electric JRS8 technical-4

People Electric JRS8 technical-5

Additional information
Model

JRS8

Frame

JRS8-16, JRS8-25, JRS8-45, JRS8-85, JRS8-105, JRS8-170, JRS8-250, JRS8-370

Current Setting Range

0.11–0.16A, 0.14–0.21A, 0.19–0.29A, 0.27–0.4A, 0.35–0.52A, 0.42–0.63A, 0.55–0.83A, 0.7–1A, 0.9–1.3A, 1.1–1.5A, 1.3–1.8A, 1.5–2.1A, 1.7–2.4A, 2.1–3A, 2.7–4A, 3.4–4.5A, 4–6A, 5.2–7.5A, 6.3–9A, 7.5–11A, 9–13A, 12–17.6A, 0.1–0.16A, 0.16–0.25A, 0.25–0.4A, 0.4–0.63A, 0.63–1A, 1–1.4A, 2.2–3.1A, 2.8–4A, 3.5–5A, 4.5–6.5A, 6–8.5A, 10–14A, 13–19A, 18–25A, 24–32A, 0.28–0.4A, 0.45–0.63A, 0.86–1.3A, 1.1–1.6A, 1.4–2.1A, 1.8–2.5A, 2.2–3.3A, 3.5–5.2A, 4.5–6.3A, 5.5–8.3A, 7–10A, 8.6–13A, 11–16A, 14–21A, 18–27A, 25–35A, 30–45A, 6–10A, 8–14A, 12–20A, 17–29A, 25–40A, 35–55A, 45–70A, 60–110A, 27–42A, 36–52A, 45–63A, 57–82A, 70–105A, 80–115A, 90–130A, 110–160A, 140–200A, 100–160A, 160–250A, 250–400A, 310–500A

Installation Code

Z, F

Technical Documents

TECHNICAL RESOURCES

Documents for People Electric JRS8 Thermal Overload Relay, 0.1–500A

Check the exact model, rating and configuration in the linked document before ordering.

Download People Electric JRS8 manufacturer catalogue (PDF) ↗

Drawings and compliance documents

Tell us the model and destination market if you need dimensions, a wiring diagram or a certification document. Available documents and approvals depend on the exact product configuration.

Ask for product documents

Supplier: Shanghai Newtrend Electric Co., Ltd. Brand and manufacturer details are stated separately for each product.

Selection & Ordering

BEFORE YOU ORDER

Selection and ordering questions

What information is needed for a quotation?

Send the exact model or selected configuration, required quantity, destination country and any project-specific requirements. Our team will confirm availability and the matching specification.

Are the same approvals available for every configuration?

No. Standards, certificates and market acceptance must be checked for the exact manufacturer model and configuration. Request the relevant document before specifying the product.

Can I include other products in the same enquiry?

Yes. Add the required products to your quote list, set the quantities and send one enquiry with your project requirements.

Related products

People Electric CJX2-09–95 3-Pole AC Contactor, 9–95A AC-3
People Electric CJX2-09–95 3-Pole AC Contactor, 9–95A AC-3

People Electric CJX2-09–95 3-Pole AC Contactor, 9–95A AC-3

Original People Electric CJX2-09-95 AC contactor. Select the documented current and control configuration for the actual load.
People Electric RDR5 Thermal Overload Relay, 0.1–93A
People Electric RDR5 Thermal Overload Relay, 0.1–93A

People Electric RDR5 Thermal Overload Relay, 0.1–93A

Original People Electric RDR5 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA
People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA

People Electric DZ47-63 Miniature Circuit Breaker, 2–63A 4.5kA

Original People Electric DZ47-63 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDX6-63 AC Miniature Circuit Breaker, 2–63A 10kA
People Electric RDX6-63 AC Miniature Circuit Breaker, 2–63A 10kA

People Electric RDX6-63 AC Miniature Circuit Breaker, 2–63A 10kA

Original People Electric RDX6-63 AC miniature circuit breaker. Select the documented rated current, poles and tripping curve; see the manufacturer ratings and complete PDF.
People Electric RDR6 Thermal Overload Relay, 0.1–93A
People Electric RDR6 Thermal Overload Relay, 0.1–93A

People Electric RDR6 Thermal Overload Relay, 0.1–93A

Original People Electric RDR6 thermal overload relay for motor overload and phase-loss protection. Select the correct frame and current setting range; specify the installation code.
People Electric RDG8 Isolation Switch, 63A & 125A, 2P/4P
People Electric RDG8 Isolation Switch, 63A & 125A, 2P/4P

People Electric RDG8 Isolation Switch, 63A & 125A, 2P/4P

Original People Electric RDG8 AC isolation switch. Select 63A or 125A conventional heating current and 2P or 4P; operating current depends on the circuit voltage.
People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V
People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V

People Electric RDT8-PV Photovoltaic DC Fuse & Holder, 1000/1500V

Original People Electric RDT8-PV photovoltaic fuse links and matching holders. Choose the component first: 10×38 at DC1000V or 10×85 at DC1500V. Holders and fuse links are ordered separately.
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA
People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA

People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA

Original People Electric RDU8DC DC surge protective device. Select B20 (Imax 20kA) or B40 (Imax 40kA), and 2P or 3P. This page covers the DC1000V maximum continuous operating-voltage ratings.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Plastic Junction Box
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
      • People Electrical Materials
        • People MCB
        • People RCCB RCBO
        • People MCCB ACB
          • People Air Circuit Breakers
          • People Moulded Case Circuit Breakers
        • People Contactor & Overload Relays
        • People Relays
        • People Fuse & Disconnectors
        • People Inverter & Soft Starters
        • People Pushbutton & Pilot Lights
        • People Changeover Switches
        • People Capacitor & Reactors
        • People Voltage Stabilizers
        • People New Energy
        • People Motor Drive Protection
        • People Master Switches
        • People Control Transformers
        • People Rectifiers & Thyristors
        • People Industrial Plugs & Sockets
        • People Terminal Blocks
        • People Bells & Alarms
        • People Low Voltage Switchgear
        • People High Voltage Switchgear
        • People Other Equipment
        • People Power Transformers
          • People Dry Type Transformers
          • People Oil Immersed Transformers
          • People Combination Transformers & Substations
        • People Hazardous Area Equipment
          • People Explosion-Proof Fans
          • People Industrial & Hazardous Area Lighting
          • People Explosion-Proof Electrical Apparatus
          • People Explosion-Proof Conduit & Fittings
          • People Dust Explosion-Proof Equipment
          • People Plastic Explosion-Proof Equipment
        • People Energy Meters
        • People Measuring Instruments
        • People Cables & Conductors
      • Noark Electrical Materials
        • Noark UL ACB
        • Noark UL MCCB
        • Noark UL MCB
        • Noark UL RCCB
        • Noark UL Enclosed Breakers
        • Noark UL Contactor & Overload Relays
        • Noark UL Inverter & Soft Starters
        • Noark UL Motor Protection & Manual Starters
        • Noark UL Fuse & Disconnectors
        • Noark UL Surge Protection Devices
        • Noark UL DC Circuit Breakers & Disconnectors
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • SHA IP65 Distribution Box with Transparent Cover SHA IP65 Distribution Box with Transparent Cover
  • SHEN IP67 Compact Circuit-Breaker Enclosure SHEN IP67 Compact Circuit-Breaker Enclosure
  • NewTrend XB45 Distribution Enclosure, 45-72 Modules NewTrend XB45 Distribution Enclosure, 45-72 Modules
  • SHXC Wall-Mount MCCB and PV Equipment Enclosure SHXC Wall-Mount MCCB and PV Equipment Enclosure
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...

    Request a Quote 0 WhatsApp

    SHANGHAI NEWTREND ELECTRIC

    Your quote request

    Select products, add quantities and tell us what you need.

    You can send a general enquiry, or browse our products and add items to this list.

    We use your details to respond to this enquiry. Privacy policy

    Continue browsing