People Electric BSMJ self-healing low-voltage shunt capacitors are used to improve network power factor. The required kvar must be selected for the actual circuit voltage, load and harmonic conditions. This page covers the detailed rectangular three-phase delta versions in the manufacturer specification tables.
Technical selection summary
| Manufacturer / series | Original People Electric BSMJ rectangular self-healing shunt capacitor |
|---|---|
| Published configurations | AC400V or AC450V, 50Hz; three-phase delta connection; 3–50kvar in the exact steps below |
| Capacitance tolerance | 0 to +10% |
| Dissipation factor | Less than 0.10% as stated |
| Maximum overload values | 110% rated voltage; 130% rated current as stated. These do not replace application-specific harmonic/thermal design. |
| Self-discharge statement | Residual voltage ≤50V at 1 minute after disconnection, as stated; verify safe isolation and discharge before contact |
| Reconnection | Allow at least 3 minutes before reconnecting, according to the original notice |
| Harmonic conditions | Do not directly install in a severe-harmonic system without a correctly designed anti-harmonic reactor |
| 400V ratings below | Each row lists kvar / total capacitance (µF) / rated current (A) |
| 400V / 3kvar | 59µF total / 4.3A |
| 400V / 5kvar | 99µF total / 7.2A |
| 400V / 7.5kvar | 149µF total / 10.8A |
| 400V / 8kvar | 158µF total / 11.5A |
| 400V / 10kvar | 198µF total / 14.4A |
| 400V / 12kvar | 238µF total / 17.3A |
| 400V / 14kvar | 278µF total / 20.2A |
| 400V / 15kvar | 298µF total / 21.7A |
| 400V / 16kvar | 318µF total / 23.1A |
| 400V / 18kvar | 358µF total / 26A |
| 400V / 20kvar | 398µF total / 28.9A |
| 400V / 25kvar | 498µF total / 36A |
| 400V / 30kvar | 597µF total / 43.3A |
| 400V / 40kvar | 796µF total / 57.7A |
| 400V / 50kvar | 995µF total / 72.2A |
| 450V ratings below | Each row lists kvar / total capacitance (µF) / rated current (A) |
| 450V / 3kvar | 47µF total / 3.8A |
| 450V / 5kvar | 78µF total / 6.4A |
| 450V / 7.5kvar | 118µF total / 9.6A |
| 450V / 8kvar | 126µF total / 10.3A |
| 450V / 10kvar | 157µF total / 12.8A |
| 450V / 12kvar | 188µF total / 15.4A |
| 450V / 14kvar | 220µF total / 18A |
| 450V / 15kvar | 236µF total / 19.2A |
| 450V / 16kvar | 251µF total / 20.5A |
| 450V / 18kvar | 283µF total / 23A |
| 450V / 20kvar | 314µF total / 25.7A |
| 450V / 25kvar | 393µF total / 32A |
| 450V / 30kvar | 471µF total / 38.5A |
| 450V / 40kvar | 629µF total / 51.3A |
| 450V / 50kvar | 786µF total / 64.2A |
| Rectangular case schedule | 3/5kvar: A case H115mm; 7.5/8: A H135; 10/12: A H175; 14/15/16: A H215; 18/20: A H245; 25: B H215; 30: B H245; 40: B H300; 50: C case. Use the original drawing for exact mounting geometry. |
| Standard stated | IEC 60831-1996 |
The published selectors cover only the fully tabulated 400V/450V, 50Hz, three-phase delta configurations. Cylindrical Y variants, star-neutral versions, other voltages and other series on the shared source page require separate exact specifications. Total capacitance is the catalogue total, not a per-phase value. Confirm protection, switching, discharge and reactor coordination before ordering.
Typical applications
- Power-factor correction in suitably designed low-voltage three-phase distribution.
- Replacement rectangular shunt capacitors requiring an exact voltage, kvar, connection and mounting match.
Specify your enquiry
For a focused quotation, include:
- Rated voltage, kvar, 50Hz and three-phase delta connection.
- Actual network voltage, harmonic conditions, reactor arrangement and switching duty.
- Required case/mounting dimensions, protection and discharge requirements, quantity and destination.