NewTrend · cabinet advanced static var generator
Product overview
NewTrend Y-ASVG-Cabinet combines AC distribution, ASVG modules and monitoring in a floor-standing system for reactive-power and harmonic-current compensation. Supported220–690V configurations also provide three-phase unbalance compensation. The five voltage platforms have different reactive-capacity ranges from50 to900kvar. Exact capacity and module arrangement are specified within the relevant platform range.
Technical selection summary
| Model | Y-ASVG-Cabinet |
|---|---|
| Cabinet composition | AC distribution, ASVG modules and monitoring system |
| AC 220V capacity range | 50–300kvar |
| AC 380V capacity range | 100–600kvar |
| AC 500V capacity range | 90–540kvar |
| AC 690V capacity range | 100–720kvar |
| AC 800V capacity range | 150–900kvar |
| Exact cabinet capacity | Project-specific within the published voltage-platform range; discrete steps not specified in the catalogue |
| Operating voltage tolerance | 220/380/500V: -20% to +20%; 690V: -20% to +15%; 800V: -20%, 850V maximum |
| Grid configuration | 220–690V: 3P3W / 3P4W; 800V: 3P3W only |
| Function | 220–690V:reactive, harmonic and three-phase unbalance compensation, individually or combined;800V:reactive and harmonic only |
| Reactive compensation rate | ≥99%, September 2026 catalogue |
| Harmonic compensation | 2nd–50th order, individually adjustable; current harmonic compensation rate≥95% |
| Harmonic-current rating | A separate harmonic-current A rating is not specified for each kvar capacity |
| Neutral-line filtering | 220–690V neutral-connected applications:2× phase filtering capacity;3× customization described separately;800V:none |
| Residual unbalance | ≤5% on supported220–690V configurations; unavailable at800V |
| Full response time | Reactive<10ms;harmonic<40ms |
| Operating frequency | 50/60Hz; 45–63Hz range |
| Overall efficiency | ≥97% |
| Switching frequency | 220/380V: 16kHz; 500/690/800V: 12.8kHz |
| Current sampling | Two external current-sampling channels |
| Communication | 2× RS485; Wi-Fi supported |
| Overload capability | 1.2× rated for 60 seconds |
| Mounting / cable entry | Vertical floor-standing; top and bottom cable entry |
| Protection rating | IP20; IP54 customization described separately in catalogue |
| Cooling / noise | Forced-air cooling; ≤75dB |
| Ambient temperature | -10 to +50°C; above 40°C derating, catalogue capacity reduction ≤30% |
| Relative humidity | ≤90%, no condensation at monthly minimum 25°C |
| Altitude | <2000m; above 2000m derate per GB/T 3859.2 |
| Pollution degree | ≤Class III |
| Protection functions | Overload, software/hardware overcurrent, grid over-/undervoltage, voltage unbalance, power-supply failure, overtemperature, abnormal frequency and short circuit protection |
| Catalogue cabinet outline | 1250 × 1000 × 2200mm as listed; confirm project capacity and arrangement |
| Parallel operation | Multiple modules supported |
Operation
- The cabinet connects in parallel with the load and integrates AC distribution, ASVG modules and system monitoring.
- The220–690V platforms support individual or combined reactive, harmonic and three-phase unbalance compensation. The800V platform supports reactive and harmonic compensation without unbalance correction.
- Neutral-line filtering is2× phase filtering capacity where applicable;3× is a separately described customization. The800V3P3W platform has no neutral-line filtering.
Typical applications
- Industrial distribution with changing reactive and nonlinear loads
- Centralized cabinet installations requiring reactive and harmonic compensation
- Supported220–690V three-phase load-unbalance applications
View or download Y-ASVG-Cabinet original catalogue, September 2026 (PDF)
Product reference images and drawings
Main and gallery photographs are two original factory cabinet-family enclosure examples; the exact cabinet arrangement depends on capacity and module selection. The catalogue lists1250×1000×2200mm; confirm the outline for the project configuration. The kvar ranges are reactive ratings, not separate harmonic-current ratings. Installation and wiring must be performed by qualified electricians.