Chint NJS1 Time Delay Relay Chint NJS1 Time Delay Relay
  • Home
  • Products
    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Automation & Control

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Circuit Breaker & Fuses

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Din-Rail Mounted Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Distribution Box & Cabinet

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Load Center & Meter Bases

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Solar PV Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Electrical Accessories

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NJS1 Time Delay Relay Chint NJS1 Time Delay Relay
Search
Chint NJS1 Time Delay Relay
Chint NJS1 Time Delay Relay
Chint NJS1 Time Delay Relay
Click to enlarge
Chint NJS1 Time Delay Relay
Chint NJS1 Time Delay Relay
Chint NJS1 Time Delay Relay
Home Chint Electrical Materials Chint Relays Chint NJS1 Time Delay Relay
Chint NQ2 DOL Starter
Chint NQ2 DOL Starter
Back to products
CJ40 Heavy Duty AC Contactor (63A-1000A)
CJ40 Heavy Duty AC Contactor (63A-1000A)

Chint NJS1 Time Delay Relay

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:NJS1
Contact Load:High Power
Protect Feature:Sealed
Time Range
Supply Voltage
Delay Function
SKU: 1769742819825557504 Category: Chint Relays
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Chint original NJS1 NJS1-2Z NJS1-11 NJS1-K NJS1-S Time Delay Relay

   

Chint NJS1 Series Time-Delay Relay is applicable for controlling circuit @ A.C. 50Hz/60Hz, up to 380V rated voltage or up to D.C.240V rated voltage as delay element to make or break circuit according to preset time.

Chint NJS1 Series Time-Delay Relay is applicable for controlling circuit @ A.C. 50Hz/60Hz, up to 380V rated voltage or up to D.C.240V rated voltage as delay element to make or break circuit according to preset time.

Additional information
Time Range

0.1-1s, 1-10s, 0.1-10s, 1-60s, 0.1-6min, 1-6min, 1-60min, 1-10h

Supply Voltage

AC 24V, AC 220V, AC 380V, DC 24V

Delay Function

On-Delay, Off-Delay, Cycle, Star-Delta

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Chint NJS1 Time Delay Relay.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Chint Phase Failure and Phase Sequence Protection Relay
Chint Phase Failure and Phase Sequence Protection Relay

Chint Phase Failure and Phase Sequence Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:XJ3
Contact Load:High Power
Protect Feature:Sealed
Chint JSZ6 Time Delay Relay

Chint JSZ6 Time Delay Relay

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:JSZ6-2 JSZ6-4
Contact Load:High Power
Protect Feature:Sealed
Chint NJYB3 Voltage Protection Relay

Chint NJYB3 Voltage Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NJYB3
Contact Load:High Power
Protect Feature:Sealed
Chint JQX-10F Miniature Power Relay

Chint JQX-10F Miniature Power Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:JQX-10F
Contact Load:High Power
Protect Feature:Sealed
Chint NJBK10 Motor Protector
Chint NJBK10 Motor Protector

Chint NJBK10 Motor Protector

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NJBK10
Contact Load:High Power
Protect Feature:Sealed
Chint JD-5 Motor Protection Relay
Chint JD-5 Motor Protection Relay

Chint JD-5 Motor Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:JD-5
Contact Load:High Power
Protect Feature:Sealed
Chint NJB1-X1 Voltage Protection Relay
Chint NJB1-X1 Voltage Protection Relay

Chint NJB1-X1 Voltage Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NJB1-X1
Contact Load:High Power
Protect Feature:Sealed
Chint NJMC1 Pulse Relay
Chint NJMC1 Pulse Relay

Chint NJMC1 Pulse Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:NJMC1
Contact Load:High Power
Protect Feature:Sealed
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NJS5 Time Relay Chint NJS5 Time Relay
  • Chint JD-5E Integrated Motor Protector Chint JD-5E Integrated Motor Protector
  • Chint NJYB3 Voltage Protection Relay Chint NJYB3 Voltage Protection Relay
  • NJB1-S Voltage Protection Relay NJB1-S Voltage Protection Relay
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the truck.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...