The ABB PSTX30-600-70 softstarter is rated 30A IEC and 15kW at 400V for normal in-line starting duty. It operates on a three-phase 208-600V AC supply with 100-250V AC control power and built-in bypass. ABB ordering reference: 1SFA898103R7000.
These CNC YCCH6 automatic modular contactors provide electrically controlled switching for household and similar low-inductance loads. The selected 25A versions cover 2NO, 3NO+1NC and 4NO contact arrangements. Their compact format is intended for distribution-board installation.
The YCQR2-045 soft starter provides controlled starting and stopping of a compatible 45kW three-phase AC squirrel-cage motor. Microprocessor-controlled thyristors limit starting current or ramp the applied voltage, then transfer operation to a bypass contactor.
The ABB PSR30-600-70 softstarter is rated 30A IEC and 15kW at 400V for normal in-line starting duty. It operates on a three-phase 208-600V AC supply with 100-240V AC control power and built-in bypass. ABB ordering reference: 1SFA896109R7000.
The YCM1-250L is a thermal-magnetic moulded case circuit breaker for power distribution. The 250A frame provides overload and short-circuit protection with the L breaking-capacity class. This page covers the direct-handle, three-pole distribution versions.
The ABB PSR60-600-70 softstarter is rated 60A IEC and 30kW at 400V for normal in-line starting duty. It operates on a three-phase 208-600V AC supply with 100-240V AC control power and built-in bypass. ABB ordering reference: 1SFA896112R7000.
The YCX8-IFS photovoltaic combiner box houses DC-side protection and isolation between PV strings and compatible inverter inputs. The original technical table lists 1-input/1-output and 6-input/2-output enclosures with a maximum DC1000V operating voltage.
The YCS8-S is a pluggable photovoltaic DC surge protective device for diverting transient overvoltage to earth. It offers T2 and T1+T2 versions, thermal disconnection and a green/red condition window. Optional remote signalling reports module condition.
The CNC CJX2-3210 AC contactor switches and controls compatible three-phase motors. Its code identifies the 32A current rating and one normally open auxiliary contact. The original product photograph retains the CNC brand and CJX2-3210 model marking.