NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
Search
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
Click to enlarge
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
Home Electrical Accessories Others NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor
LC1D18 3P 18A TeSys AC Contactor 24V-240V Coil Options
LC1D18 3P 18A TeSys AC Contactor 24V-240V Coil Options
Back to products
LC1D32 3P 32A AC Contactor 24V-240V Coil Options
LC1D32 3P 32A AC Contactor 24V-240V Coil Options

NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:9A ~ 95A
Number of Pole
Main Circuit Rating Voltage
SKU: 1600723221099 Category: Others
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

LC1D 3 pole, 4 pole AC coil or DC coil Magnetic Contactor

LC1D series Contactors are suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently starting & controlling the motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical-interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC 947-2, VDE 0660 & BS5452. 

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Number of Pole

3, 4

Main Circuit Rating Voltage

Other

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for NewTrend LC1D65AM7C TeSys Deca 3P 65A 18.5kW 230V AC Contactor.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A
DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A

DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A

BCD Curve:C
Type:MCB
Brand Name:Delixi
Place of Origin:China
Model Number:CDB6i
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:220V,400V ,230V,240V,380V
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker
THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

THQL2120 2-Pole 20A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,230V,240V,120V
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
Sold out
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:GC, iCT
Phase:1
Main Circuit Rating Current:12A ~ 100A
Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC88P
Phase:1
Main Circuit Rating Current:500A
Sold out
2P/4P Auto Resettable Differential Switch RCCB RCBO 40A 63A
2P/4P Auto Resettable Differential Switch RCCB RCBO 40A 63A

2P/4P Auto Resettable Differential Switch RCCB RCBO 40A 63A

BCD Curve:C
Type:RCCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:RD9L-R + YL9
Rated Frequency (Hz):50/60Hz
Protection:LSIG
Breaking Capacity:6kA
Rated Voltage:230/400V
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
Sold out
LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D258
Phase:3
Main Circuit Rating Current:25A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • DELIXI TDGC TDGC2 Single-Phase Contact Voltage Regulator DELIXI TDGC TDGC2 Single-Phase Contact Voltage Regulator
  • 100 Amp/125 Amp Circuit Breaker Panel LoadCenter 100 Amp/125 Amp Circuit Breaker Panel LoadCenter
  • CHINT YBLXW-5 Industrial Micro Switch Limit Switch CHINT YBLXW-5 Industrial Micro Switch Limit Switch
  • DELIXI DZ47vZ DC Miniature Circuit Breaker 1P-4P DELIXI DZ47vZ DC Miniature Circuit Breaker 1P-4P
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...