NewTrend / OEM · High-voltage DC contactor
Product overview
This NewTrend G300H / G300HS listing covers a normally open single-pole contactor for DC power switching. The listed current is 300 A; the permissible switching duty depends on circuit voltage, load, temperature and the exact contactor version.
Technical selection summary
| Model reference | G300H / G300HS |
|---|---|
| Listed current | 300 A |
| Contact form | SPST-NO / 1 normally open main contact |
| Listed coil choices | 12 V DC or 24 V DC; confirm full suffix |
| Main-circuit selection | Confirm maximum working voltage and make/break capability for the actual DC load |
| Drawing | Contact schematic and outline shown below for identification |
Select the exact suffix for the required DC working voltage. Do not treat current rating alone as a guaranteed interrupting rating. Confirm exact voltage, polarity requirements and duty from the supplied unit’s nameplate and test data. Confirm the contact voltage drop, economizer/holding power, coil suppression and polarity for the exact suffix. Family tables and drawings do not establish these features for every contactor.
Typical applications
- DC battery-system isolation subject to confirmed ratings
- Charging-equipment power switching
- OEM DC power assemblies
Product reference images and drawings
Use the matching model and version in the reference data. Confirm the applicable rating, test conditions and dimensions against the exact supplied unit.
Model comparison
| Model | G50H | G100H | G150H | G200H | G250H | G300H |
| Rated Current | 50A | 100A | 150A | 200A | 250A | 300A |
| Contact type | SPST-NO | |||||
| Contact rated voltage & current | 12-1000Vdc | |||||
| Coil voltage | 12Vdc, 24Vdc, 48Vdc | |||||
| Coil power consumption | ≤6W | |||||
| Output Connectors | M5 Bolt and Lockwasher Connections | |||||
| Connectors | Wire Leads for Control Circuit | |||||
| Pickup voltage | ≤75%Us | |||||
| Release voltage | ≤7Vdc | |||||
| Pickup time | ≤30ms | |||||
| Release time | ≤20ms | |||||
| Electric life (450Vdc) | ≥5000 times | |||||
| Electric life (750Vdc) | ≥2000 times | ≥1000 times | ||||
| Electric life (900Vdc) | ≥2000 times | ≥1000 times | ||||
| Ingress Protections | IP67 | |||||
| Working temperature | -40 to 85°C | |||||