NewTrend W600A normally-open DC contactor,600A continuous duty. Select the actual DC coil supply.
Technical selection summary
| Parameter | Specification |
|---|---|
| Identity | NewTrendW600A;SW600 is a reference designation,not Albright original;actual photo JW600A/12V |
| Main contact | Single-pole normally-open,600A continuous per original supplier table |
| Main voltage | DC6-80V;coil voltage is separate |
| Coil supply | Separate DC12/24/36/48/72V versions from original short-description rows |
| Coil power | 11-15W per original supplier table |
| Contact voltage drop | Less than80mV |
| Operation at20C | Pull-in below66%Us;drop-out5-30%Us |
| Timing | Pull-in<30ms;drop-out<30ms |
| Dielectric test | AC1000V,50Hz,1minute |
| Endurance | Mechanical100000 / electrical20000 operations per original table |
| Mounting / dimensions | Use the exact provided W600A outline;do not substitute original Albright dimensional data |
SW600 is a comparison reference. SW560 is not automatically an equivalent supply model. The80V contact-circuit limit is not increased by a higher coil voltage;confirm the load category and switching duty for the application.
Typical applications
- Electrical panel assembly and installation
Open technical reference image
Main circuit voltage: Max 80V DC for the supplied NewTrend version. Coil voltage is selected separately. Any 48V contact-circuit marking in retained legacy reference drawings describes the earlier reference, not the current supplied rating.