Product overview
Motor control cabinet
The cabinet combines a circuit breaker, SCR starter and external bypass contactor for three-phase motor control. The bypass path carries motor current after starting.
Protection and supervision
The original tables describe 12 protections, cabinet circuit roles and enclosure dimensions. The front panel supports status monitoring and parameter setup, with remote communication options.
Model and configuration selection
Motor power options follow the published cabinet-size bands. Confirm exact motor current, supply rating and order code with the selected cabinet configuration.
Original technical diagrams


Motor protection functions
| No. | Protection Function | Technical Operational Description & Trigger Threshold |
|---|---|---|
| 1 | Start-up Timeout Protection | Shuts down immediately if motor fails to reach full rated speed within the preset acceleration ramp window. |
| 2 | Input Phase Loss Protection | Trips within < 3 seconds upon detection of missing incoming power phase on line terminals. |
| 3 | Output Phase Loss Protection | Instantaneous trip (< 3 seconds) if motor cable or output connection becomes open-circuited. |
| 4 | Three-Phase Current Unbalance | Protects motor against severe winding heating when current deviation across phases exceeds 50% (< 3s lag). |
| 5 | Starting Overload Protection | Fast thermal trip protection activated when acceleration current exceeds 5 times motor rated current (Ie). |
| 6 | Running Overload Protection | Inverse-time electronic thermal overload modeling tailored to motor continuous duty class. |
| 7 | Power Supply Over-Voltage | Inhibits start and triggers fault alarm when incoming line voltage exceeds 130% of nominal rating. |
| 8 | Power Supply Under-Voltage | Prevents motor stall and high-slip burnouts during severe grid voltage brownout conditions. |
| 9 | Load Short-Circuit Protection | Instantaneous microsecond-level gate pulse blocking coordinated with upstream molded case breaker. |
| 10 | Thyristor Over-Temperature | Internal heat-sink thermistor sensor locks out starting if junction temperature exceeds safe thermal limits. |
| 11 | Phase Sequence Detection | Verifies correct positive sequence rotation to protect machinery from unexpected reverse rotation. |
| 12 | Instantaneous Over-Current | Fast hardware comparator detection trips instantly upon locked-rotor or abnormal mechanical jamming. |
Main circuit component functions
| Component | Standard Function in Cabinet |
|---|---|
| MCCB | Short-circuit breaking & manual power isolation |
| Soft Starter | Smooth voltage/torque acceleration & deceleration control |
| Bypass Contactor | Zero-loss continuous running & thermal reduction |
| Induction Motor | Heavy-duty 3-phase squirrel cage driven machinery |
Cabinet dimensions
| Specification (Power Rating) | Overall Dimensions (mm) | Mounting Configuration | ||
|---|---|---|---|---|
| A (Width) | B (Height) | C (Depth) | ||
| 5.5 – 75 kW | 420 mm | 1000 mm | 380 mm | Compact Floor Standing / Wall Mountable |
| 90 – 220 kW | 550 mm | 1250 mm | 550 mm | Standard Heavy-Duty Floor Standing |
| 250 – 400 kW | 650 mm | 1500 mm | 650 mm | Heavy-Duty Industrial Floor Standing |
| 450 – 630 kW | 700 mm | 1750 mm | 650 mm | High-Capacity Free-Standing Cubicle |
Typical applications
Conveyors, industrial fans, agitators, air compressors and pumps.