NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
  • Home
  • Products
    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Automation & Control

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Circuit Breaker & Fuses

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Din-Rail Mounted Products

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Distribution Box & Cabinet

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Load Center & Meter Bases

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Solar PV Products

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Electrical Accessories

    NewTrend B1-125 1P–4P DC Miniature Circuit Breaker, 80–125A, Icu 10kA

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
Search
NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
Click to enlarge
NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
Home Automation & Control Motor Soft Starters NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW
CNC Electric YCL8-01 Liquid Level Control Relay AC/DC24–240V 10A
CNC Electric YCL8-01 Liquid Level Control Relay AC/DC24–240V 10A
Back to products
CHINT 252463 NXU-IIG 3P+N 275V 65kA Type 2 Surge Protector
CHINT 252463 NXU-IIG 3P+N 275V 65kA Type 2 Surge Protector

NewTrend YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW

A three-phase autotransformer limits starting current on squirrel-cage induction motors during infrequent starts. The 65% and 80% taps provide different voltage and starting-torque levels.

Model
Power
Add to Enquiry
SKU: yfx01-autotransformer-starter-box Category: Motor Soft Starters Brand: NewTrend
  • Description
  • Catalog
Description

Product overview

Reduced-voltage starting

A three-phase autotransformer limits starting current on squirrel-cage induction motors during infrequent starts. The 65% and 80% taps provide different voltage and starting-torque levels.

Duty and protection

The manufacturer limits starting current to four times motor rated current and cumulative start duration to 30 seconds. Observe the documented cooling and environmental requirements. The starter provides overload, under-voltage and phase-loss protection.

Model and configuration selection

The published family range starts at 10 kW. Model buttons use the explicit power examples in the source nomenclature and the YFX01 prefix. Confirm voltage pairing and any additional ratings before ordering.

YFX01 Autotransformer Reduced-Voltage Starting Boxes, 10–320 kW

Model designation

Symbol SegmentDesignationTechnical Meaning & Explanation
YFEnterprise CodeChina · Yongfan Electric Co., Ltd. manufacturer identifier
XVoltage Reducing Starting BoxStep-down reduced voltage starter enclosed box type
01Autotransformer SeriesDesign number 01 indicating autotransformer starting scheme
□□Rated PowerRated capacity of controlled electric motor in kilowatts (kW) (e.g., 14, 20, 28, 40, 55, 75, 80, 100, 115, 135, 160, 180, 200, 225, 260, 280, 300, 320kW)

Starting duty and protective functions

Performance ParameterSpecified Limit / ValueOperational Requirement & Engineering Rationale
Maximum Starting Current≤ 4 × IeControlled via autotransformer step-down taps to minimize grid shock during motor acceleration
Max Starting Time (Single / Cumulative)≤ 30 sMaximum permissible energized duration for autotransformer windings during starting transition
Mandatory Cooling Duration≥ 2 HoursRequired after cumulative 30s starting time to prevent internal coil thermal relay overload trip
Permissible Duty CycleLong-Time IntermittentDesigned strictly for infrequent motor starting; not suitable for continuous cycling or high-frequency starts
Integrated Motor ProtectionsTri-Protection SystemFull coverage against motor thermal overload, electrical under-voltage, and phase loss / open phase faults

Autotransformer taps

Autotransformer TapVoltage Ratio (% Ue)Starting Torque (% Tst)Factory Setting & Application Note
Standard Tap (Default)65%Approx. 42.25%Factory Default Connection: Suitable for standard industrial loads such as centrifugal pumps, fans, and unloaders with minimal inrush impact.
High Torque Tap80%Approx. 64.00%Optional Connection: Easily reconnected on-site if user application requires higher starting torque (e.g. crushers, loaded conveyors, heavy mills).

Environmental and installation limits

ItemEnvironmental / Operating ParameterSpecified Operating LimitsEngineering Notes & Precautions
(1)Altitude Limit≤ 2000 mDerating required if installed above 2000m
(2)Ambient Air Temperature-5°C to +40°C (24h Average ≤ +35°C)Minimum ambient temperature floor is -5°C
(3)Atmospheric Relative Humidity≤ 50% at +40°C
Wettest month: mean min temp ≤ +20°C, mean max RH ≤ 90%
Higher RH allowable at lower temperatures; anti-condensation measures required if temperature fluctuates
(4)Pollution DegreeGrade 3Standard industrial harsh electrical environment
(5a)Installation Inclination≤ 5° from vertical/horizontal planeEnsures proper vertical orientation of magnetic contactors
(5b)Installation CategoryCategory II & Category IIICompatible with primary sub-distribution and branch circuits
(6)Mechanical Vibration & ImpactPlace without noticeable vibration or impactAvoid direct mounting on intensely vibrating machinery frames
(7)Surrounding Atmospheric MediaNon-explosive medium; free of corrosive gases & conductive dustMust not contain gases/dust that corrode metals or impair insulation

Electrical ratings and applicable standards

Specification ParameterRated Engineering ValueStandard & Compliance Notes
Product Series ModelYFX01 SeriesAutotransformer reduced voltage starting box
Manufacturing StandardGB14048.4-2003 / JB/T8752-1998National & machinery industry electrical standards
Rated Operational FrequencyAC 50 HzThree-phase power grid
Rated Operational VoltageUp to 660V and below (380V / 660V)Three-phase 380V standard / 660V compatible
Controlled Motor Capacity Range10 kW – 320 kWThree-phase squirrel-cage induction motors
Autotransformer Voltage Taps65% (Factory Default) and 80%Dual tap selection for torque/inrush matching
Maximum Starting Inrush Current≤ 4 × IePeak line current during start sequence
Starting Duration Limitation≤ 30 secondsSingle start or cumulative continuous starts
Cooling Requirement After 30s Start≥ 2 HoursGuarantees thermal safety of autotransformer core & coil
Operating Duty ModeLong-Time Intermittent StartingStrictly designed for infrequent motor startup
Control Mode Configuration≤ 75kW: Auto Control
≥ 80kW: Manual & Auto Dual Control
Selected via transfer switch with adjustable time relay
Protective FunctionsOverload, Under-Voltage, Phase LossComprehensive protection for motor and supply grid

Typical applications

Pumps, fans, conveyors, compressors and other three-phase squirrel-cage motor loads.

Catalog
NameSizeRelease timeOperate

Related products

NewTrend Full-Time Online SCR Intelligent Motor Soft Starters, 5.5–630 kW
NewTrend Full-Time Online SCR Intelligent Motor Soft Starters, 5.5–630 kW

NewTrend Full-Time Online SCR Intelligent Motor Soft Starters, 5.5–630 kW

Three-phase input feeds a three-phase motor through a full-time online SCR power stage. The unit ramps motor acceleration and remains in circuit during running.
NewTrend Full-Time Online Intelligent Soft Start Cabinets, 5.5–630 kW
NewTrend Full-Time Online Intelligent Soft Start Cabinets, 5.5–630 kW

NewTrend Full-Time Online Intelligent Soft Start Cabinets, 5.5–630 kW

This configuration keeps the SCR power stage in circuit during normal operation. The source diagram shows a complete cabinet with a main breaker and motor output. The original title mentions bypass, while its description and schematic describe full-time online operation.
NewTrend External Bypass Intelligent Soft Start Cabinets, 5.5–630 kW
NewTrend External Bypass Intelligent Soft Start Cabinets, 5.5–630 kW

NewTrend External Bypass Intelligent Soft Start Cabinets, 5.5–630 kW

The cabinet combines a circuit breaker, SCR starter and external bypass contactor for three-phase motor control. The bypass path carries motor current after starting.
NewTrend Intelligent Three-Phase AC Motor Soft Starters, Bypass and Online Series
NewTrend Intelligent Three-Phase AC Motor Soft Starters, Bypass and Online Series

NewTrend Intelligent Three-Phase AC Motor Soft Starters, Bypass and Online Series

The manufacturer identifies five structural types: A external bypass starter, B bypass cabinet, C online starter, D online cabinet and E built-in bypass starter.
NewTrend External Bypass Intelligent Motor Soft Starters, 5.5–630 kW
NewTrend External Bypass Intelligent Motor Soft Starters, 5.5–630 kW

NewTrend External Bypass Intelligent Motor Soft Starters, 5.5–630 kW

The microprocessor controls SCR conduction during starting and stopping. Torque and current control reduce the starting shock on the supply and driven equipment.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
    • AFDD & RCBO
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
    • Power Quality
      • Terminal Power Quality Regulators
      • Automatic Voltage Conditioners
      • Advanced Static Var Generators
      • Active Harmonic Filters
      • Static Var Generators
    • Rotary Encoders
    • Switching Power Supplies
    • Communication Gateways
    • PID Temperature Controllers
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
    • Digital Timer Switches
    • Mechanical Timer Switches
    • DIN Rail Signal Indicators
    • Overcurrent Protectors
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • Plastic Junction Box
    • Aluminum Junction Box
    • Optical Fiber Boxes
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • TYE Load Center
    • Meter Bases
    • Steel Junction Box
    • Safety Switches
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
    • Solar Cables
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Din Rail
    • Meter & Transformer
    • Wiring Accessories
      • Waterproof Connectors
      • Cable Glands
      • Busbars
      • Quick-Disconnect Terminals
      • Quick-Splice Connectors
      • IEC Power Entry Modules
    • EV Charging Accessories
    • Smart Sockets & Plug-in Protectors
    • Others
      • ABB Electrical Materials
        • ABB MCCB
        • ABB Contactor
        • ABB MCB
        • ABB Motor Protection
        • ABB Overload Relay
        • ABB RCCB
        • ABB RCBO
        • ABB UL MCCB
        • ABB Switch Disconnector
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
      • People Electrical Materials
        • People MCB
        • People RCCB RCBO
        • People MCCB ACB
          • People Air Circuit Breakers
          • People Moulded Case Circuit Breakers
        • People Contactor & Overload Relays
        • People Relays
        • People Fuse & Disconnectors
        • People Inverter & Soft Starters
        • People Pushbutton & Pilot Lights
        • People Changeover Switches
        • People Capacitor & Reactors
        • People Voltage Stabilizers
        • People New Energy
        • People Motor Drive Protection
        • People Master Switches
        • People Control Transformers
        • People Rectifiers & Thyristors
        • People Industrial Plugs & Sockets
        • People Terminal Blocks
        • People Electromagnets
        • People Bells & Alarms
        • People Low Voltage Switchgear
        • People High Voltage Switchgear
        • People Other Equipment
        • People Power Transformers
          • People Dry Type Transformers
          • People Oil Immersed Transformers
          • People Combination Transformers & Substations
        • People Hazardous Area Equipment
          • People Explosion-Proof Fans
          • People Industrial & Hazardous Area Lighting
          • People Explosion-Proof Electrical Apparatus
          • People Explosion-Proof Conduit & Fittings
          • People Dust Explosion-Proof Equipment
          • People Plastic Explosion-Proof Equipment
        • People Energy Meters
        • People Measuring Instruments
        • People Cables & Conductors
      • Noark Electrical Materials
        • Noark UL ACB
        • Noark UL MCCB
        • Noark UL MCB
        • Noark UL RCCB
        • Noark UL Enclosed Breakers
        • Noark UL Contactor & Overload Relays
        • Noark UL Inverter & Soft Starters
        • Noark UL Motor Protection & Manual Starters
        • Noark UL Fuse & Disconnectors
        • Noark UL Surge Protection Devices
        • Noark UL DC Circuit Breakers & Disconnectors
      • CNC Electrical Materials
        • CNC Smart Circuit Breakers
        • CNC DC Contactors
        • CNC MCCB
        • CNC PV Combiner Boxes
        • CNC DC Circuit Breakers
        • CNC Surge Protection Devices
        • CNC Modular Contactors
        • CNC Soft Starters
        • CNC AC Contactors
        • CNC DC Isolators
        • CNC Rotary Changeover Switches
        • CNC Voltage Protection Relays
        • CNC Automatic Transfer Switches
        • CNC RCBO
        • CNC MCB
        • CNC Manual Changeover Switches
        • CNC Time Relays
        • CNC PV Fuse Holders
        • CNC Motor Protection
        • CNC RCCB
        • CNC Time Switches
        • CNC Liquid Level Relays
        • CNC Thermal Overload Relays
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
    • CHINT Ordering Codes
      • NXB-63 Codes
      • NM8N Codes
      • NS2 Codes
      • NCH8 Codes
      • NXU Codes
      • NXM Codes
      • NCK3 Codes
      • NB1-63 Codes
      • NC1 Codes
      • NC2 Codes
      • NXC Codes
      • NL1-63 Codes
      • NB1L Codes
      • NA1 Codes
      • NB1-63H Codes
      • NXB-125 Codes
      • NB2LE Codes
      • NXBLE-125 Codes
      • NB1-63DC Codes
      • NL210 Codes
YOU MAY ALSO LIKE…
  • NewTrend JQ150H 150A SPDT Changeover DC Contactor, 1NO+1NC NewTrend JQ150H 150A SPDT Changeover DC Contactor, 1NO+1NC
  • NewTrend TK50D Sealed DC Contactor, 50A at 220V DC, IP67 NewTrend TK50D Sealed DC Contactor, 50A at 220V DC, IP67
  • NewTrend ED125/ED250 Manual DC Emergency Disconnect, 125A/250A NewTrend ED125/ED250 Manual DC Emergency Disconnect, 125A/250A
  • NewTrend NFG30DK 30A High-Voltage DC Relay, 450V DC-1 NewTrend NFG30DK 30A High-Voltage DC Relay, 450V DC-1
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar

    Sending...

    Get a quotation 0

    SHANGHAI NEWTREND ELECTRIC

    Get a quotation

    Review your products. Send one request for everything.

    Your products 0 items

    You can send a general enquiry, or add products to this list.

    Product removed.

    Add products

    Browse all products →

    Your contact details

    We use your details to respond to this enquiry. Privacy policy