CHINT · Solid-state relay
Product overview
CHINT NJG2 solid-state relays use semiconductor switching with photoelectric isolation between the control input and load output. Select the complete phase, input, output and current code.
Technical selection summary
| SDA032 | Single-phase AC-output version, DC 3–32 V input. The 220 and 380 load-voltage suffixes refer to separate AC output ranges; select the complete current/voltage code. |
|---|---|
| TDA032 | Three-phase AC-output version with DC 3–32 V input. Match the three-phase load, current and output-voltage suffix. |
| SDD032 | Single-phase DC-input/DC-output version. The manufacturer manual and ordering table specify DC 5–32 V input and DC 12–250 V output for the listed 10 A / 15 A / 20 A versions. The family 3–32 V input and 120 A maximum do not apply universally to SDD032. |
| Thermal selection | Select the matching heatsink, ventilation and load derating from the manufacturer instructions. The nameplate maximum load current is not an unconditional cabinet operating current. |
AC and DC input/output codes identify separate configurations. The SDD032 values in the summary are specific to the listed DC-output versions. Match the exact load, current suffix, heatsink and wiring. No hermetic sealing or IP grade is specified here.
Typical applications
- Semiconductor switching in industrial control circuits.
- AC or DC load circuits matched to the specific SDA032, TDA032 or SDD032 version.