NewTrend / OEM · PCB-pin miniature contactor
Product overview
This NewTrend / OEM LP1K09 selection concerns a 9 A frame with a KD 100 V DC coil reference. Confirm the complete manufacturer code and PCB-pin construction before replacing an existing board-mounted contactor.
Technical selection summary
| Frame | LP1K09 |
|---|---|
| Listed current | 9 A; confirm utilization category and voltage |
| Coil code | KD: 100 V DC in the supplied family code table |
| Main contacts | 3 poles; confirm auxiliary NO/NC suffix |
| Connection | PCB-pin version required; confirm pin pitch and full code |
DIN-rail and PCB-pin versions are different constructions. A KD coil suffix alone does not identify the terminal arrangement. Match the actual pin layout, contact arrangement and coil voltage to the installed unit. Confirm screw-clamp, Faston, spring-terminal or PCB-pin construction and its matching outline. Auxiliary blocks, LR2K overload relays, reversing interlocks and star-delta assemblies require a documented compatible combination; motor-power data must match voltage and utilization category.
Typical applications
- PCB-based control assemblies
- Compact OEM control equipment
- Replacement with matched pin layout
Product reference images and drawings
Use the matching model and version in the reference data. Confirm the applicable rating, test conditions and dimensions against the exact supplied unit.
Model comparison
| Model Number | LC1K06 | LC1K09 | LC1K12 | LC1K16 | LP1K06 | LP1K09 | LP1K12 | LP1K16 |
| Rated operational current (AC-3, 380V) | 6A | 9A | 12A | 16A | 6A | 9A | 12A | 16A |
| Rated operational current (AC-3, 660V) | 5A | 7.5A | 10A | 12A | 5A | 7.5A | 10A | 12A |
| Coil voltage (Control circuit voltage) | AC 230V 240V 380V 415V | DC 220V 230V 240V 250V | ||||||
| Rated operational voltage | 380V, 660V | |||||||
| Rated insulation voltage | 690V | |||||||
| Main and auxiliary contacts | 3P+NO, 3P+NC, 2NO+2NC, 4NO | |||||||
| Motor power (AC-3, 220/240V) | 1.5KW | 2.2KW | 3KW | 3KW | 1.5KW | 2.2KW | 3KW | 3KW |
| Motor power (AC-3, 380/415V) | 2.2KW | 4KW | 5.5KW | 7.5KW | 2.2KW | 4KW | 5.5KW | 7.5KW |
| Motor power (AC-3, 440V) | 3KW | 4KW | 5.5KW | 7.5KW | 3KW | 4KW | 5.5KW | 7.5KW |
| Motor power (AC-3, 500/660/690V) | 3KW | 4KW | 4KW | 4KW | 3KW | 4KW | 4KW | 4KW |
| Mouting type | DIN Rail / PCB Solder Pin / Plate | |||||||
| Coil Pull-In Voltage | 0.85-1.1 Us | |||||||
| Coil Drop-Out Voltage | 0.2-0.75 Us | ≤0.2 Us | ||||||
| Coil power | Pull-In 40VA, Maintain 4VA | |||||||
| Coil power consumption | 1.2W | |||||||
| Coil Pull-In time | 6-18 ms | |||||||
| Coil Drop-Out time | 5-12 ms | |||||||
| Electrical life | 500 thousand times | |||||||
| Mechanical life | 100 thousand times | |||||||
| Ambient air temperature | -5…40 °C | |||||||
| Operating altitude | 2000 m without derating in temperature | |||||||
Control coil voltage codes
| LC1K (AC voltage coil) | |||||||||||||||||
| Volts (50/60Hz) | 12 | 20 | 24 | 36 | 42 | 48 | 110 | 115 | 120 | 127 | 200/ 208 | 220/ 230 | 230 | 230/ 240 | 256 | 277 | 380/ 400 |
| Code | J7 | Z7 | B7 | C7 | D7 | E7 | F7 | FE7 | G7 | FC7 | L7 | M7 | P7 | U7 | W7 | UE7 | Q7 |
| Volts (50/60Hz) | 400 | 400/ 415 | 440 | 480 | 500 | 575 | 600 | 660/ 690 | |||||||||
| Code | V7 | N7 | R7 | T7 | S7 | SC7 | X7 | Y7 | |||||||||
| LP1K (DC voltage coil) | |||||||||||||||||
| Volts | 12 | 20 | 24 | 36 | 48 | 60 | 72 | 100 | 110 | 125 | 155 | 174 | 200 | 220 | 230 | 240 | 250 |
| Code | JD | ZD | BD | CD | ED | ND | SD | KD | FD | GD | PD | QD | LD | MD | MPD | MUD | UD |
Complete model number explained
| LP1K09105BD: | |
| LP1K means DC coil contactor, LC1K means AC coil contactor | |
| 09 means AC-3 9A rated current | |
| 10 means NO auxiliary contact, 01 means NC auxiliary contact | |
| 5 means PCB Solder Pin type, without 5 means regular DIN Rail type | |
| BD means the coil voltage code |