NF-SS series MCCB NF-SS series MCCB
  • Home
  • Products
    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Automation & Control

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Circuit Breaker & Fuses

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Din-Rail Mounted Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Distribution Box & Cabinet

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Load Center & Meter Bases

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Solar PV Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Electrical Accessories

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
NF-SS series MCCB NF-SS series MCCB
Search
NF-SS series MCCB
Click to enlarge
Home Circuit Breaker & Fuses MCCB Circuit Breaker NF-SS series MCCB
CJ40 Heavy Duty AC Contactor (63A-1000A)
CJ40 Heavy Duty AC Contactor (63A-1000A)
Back to products
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB

NF-SS series MCCB

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:NF-CS
Breaking Capacity:10-50kA
Rated Voltage:max to 690V
Type:Moulded Case
Poles
Rated Current
SKU: 60046078969 Category: MCCB Circuit Breaker
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

NF-SS series MCCB NF30-SS NF50-SS NF60-SS NF100-CS NF250-SS NF400-SS NF630-SS NF800-SS Circuit breaker

 

Application
NF-SS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume, etc. This breaker applies to the circuit with AC50/60Hz, rated insulation voltage 660V, max rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.
Specifications
Type

Pole

number
Rated current (A)
Breaking capacity (KA)
AC(P1/P2)
240
380
415
500
600
660
NF30-SS
2
3,5,10,15,20,30
5/5
5/2.5
2.5/1.5
2.5/1.0
–
–
3
NF50-SS
3
10,20,30,40,50
5/10
10/7.5
7.5/5
7.5/5
2.5/1.5
–
NF60-SS
3
10,20,30,40,50,60
5/10
10/7.5
7.5/5
7.5/5
2.5/1.5
–
NF100-CS
3
60,70,100
50/42
30/20
7.5/5
15/10
10/5
5/2.5
4
NF250-SS
3
125,150,175,200,225,250
50/42
30/20
25/15
18/15
15/10
5/2.5
4
NF400-SS
3
250,300,350,400
85/60
50/35
25/20
35/25
25/18
15/10
4
NF630-SS
3
500,600,630
85/60
50/35
50/30
35/25
25/18
15/10
4
NF800-SS
3
600,700,800
85/60
50/35
50/30
35/25
25/18
15/10

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

10A – 800A

Poles

3P, 4P

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for NF-SS series MCCB.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Trip Unit Protection

How to choose between Thermal-Magnetic (TMD) and Electronic (Micrologic) trip units?

A

Thermal-magnetic trip units provide fixed or adjustable bimetallic overload and electromagnetic instantaneous short-circuit protection, ideal for standard industrial power distribution. Electronic microprocessor trip units offer precise digital dials for L (Long-time delay overload), S (Short-time delay short-circuit), I (Instantaneous short-circuit), and G (Ground-fault protection), delivering total time-current selectivity in modern switchgear.

Ics vs Icu Capacity

What is the technical distinction between Ultimate (Icu) and Service (Ics) breaking capacity?

A

Icu represents the absolute maximum fault current the breaker can safely interrupt, after which inspection or replacement may be needed. Ics represents the operational breaking capacity (50%, 75%, or 100% of Icu) that the breaker can clear repeatedly and remain fully operational without performance degradation. In critical healthcare, data center, and continuous industrial applications, specify breakers with Ics = 100% Icu.

3P vs 4P Neutral

When should a 4-Pole (4P) MCCB be specified instead of a standard 3-Pole (3P) MCCB?

A

A 4P breaker with a switched neutral is required in systems with dual power sources (generator / utility ATS transfer) to prevent circulating neutral currents, in IT distribution networks, and in commercial installations with heavy non-linear harmonic loads (LED drivers, variable speed drives) where neutral conductor current can exceed phase currents.

Motorized & Remote Operation

How to select manual rotary handles vs motorized electric operating mechanisms?

A

Direct or extended door rotary handles are specified when the MCCB is enclosed inside switchgear cubicles, providing padlocking and door-interlock safety. Motor operating mechanisms (electric operators) are required for automated SCADA control, remote PLC open/close operations, and automatic transfer switch (ATS) integration.

Terminal & Mounting Options

What terminal connection hardware and mounting configurations are available?

A

Standard front connection lugs accept copper or aluminum compression terminals and busbar connections. For high-density panel boards, extended spreader terminals, rear connection studs, and plug-in / draw-out base cassettes are available to facilitate rapid maintenance and modular swap-out.

Related products

CM1 Molded Case Circuit Breaker
CM1 Molded Case Circuit Breaker

CM1 Molded Case Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:CM1
Type:Moulded Case
Sold out
Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A
Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A

Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:Sace-Tmax
Breaking Capacity:35kA,50kA,65kA
Rated Voltage:380V
Type:Moulded Case
Sold out
Motor Operated Compact NS MCCB 630A-1600A Micrologic

Motor Operated Compact NS MCCB 630A-1600A Micrologic

Brand Name:Newtrend or OEM brand
Place of Origin:China
Province:Zhejiang
Model Number:Compact NS
Poles Number:3P or 4P
Breaking Capacity:35kA,50kA
New Type 29450 Auxiliary Contact Standard Spare Part
New Type 29450 Auxiliary Contact Standard Spare Part

New Type 29450 Auxiliary Contact Standard Spare Part

Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:29450
3VL Molded Case Circuit Breaker 160A-800A
3VL Molded Case Circuit Breaker 160A-800A

3VL Molded Case Circuit Breaker 160A-800A

Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:3VL
Rated Frequency (Hz):50/60HZ
Breaking Capacity:40kA, 65kA
Rated Voltage:690V
Type:Moulded Case
Poles Number:3
Sold out
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB
29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB

29450 Auxiliary Contact for Compact NS/NSX/CVS MCCB

Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:29450
NF-CW Series Molded Case Circuit Breaker

NF-CW Series Molded Case Circuit Breaker

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:NF-CW
Rated Frequency (Hz):50/60hz
Breaking Capacity:25kA,36kA,50kA
Rated Voltage:690V
Type:Moulded Case
Tmax T4S/T4H/T4L 3P/4P MCCB 250A/320A TMA
Tmax T4S/T4H/T4L 3P/4P MCCB 250A/320A TMA

Tmax T4S/T4H/T4L 3P/4P MCCB 250A/320A TMA

Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:T4N
Rated Frequency (Hz):50/60Hz
Breaking Capacity:50kA, 70kA, 120kA, 200kA
Rated Voltage:690V
Pole:3Pole, 4Pole
Rated Current:20A ~ 320A
Trip Unit:Thermal-Magnetic
Type:Moulded Case
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • 3VL Molded Case Circuit Breaker 160A-800A 3VL Molded Case Circuit Breaker 160A-800A
  • Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A Sace Tmax Molded Case Circuit Breaker 3P 4P 100A-1600A
  • Compact NSX 3P MCCB 160A-630A Compact NSX 3P MCCB 160A-630A
  • Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I Tmax T4 3P/4P MCCB 125A-250A TMA PR221DS-LS/I
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the plane.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...