NewTrend · Panel-Mount PV DC Isolation
Product overview
YSS.1-50 is a compact, non-polar DC isolating switch for installation inside solar inverters and other PV equipment. The confirmed offering uses the ordinary 50 A frame with 2P, 4P, 6P and 8P arrangements, plus the documented 3P, 3T, 6T and 9T circuits. Operational current depends on voltage and the number of poles connected in series.
Key features
- Panel mounting and a compact body for inverter integration.
- 50 A at 800 V or 1000 V DC in the documented two-poles-in-series circuits.
- 40 A at 1200 V DC in 2P / 4P / 6P / 8P circuits; 3T / 6T / 9T support 50 A at 1200 V DC or 40 A at 1400 V DC with three poles in series; 3P supports 32 A at 800 V DC, 25 A at 1000 V DC or 20 A at 1200 V DC.
- Arc-interruption structure with an arcing time of 3 ms.
- IEC/EN 60947-3 and GB/T 14048.3 product-page references.
- 10000 mechanical cycles and 300 electrical cycles.
Product family and offered scope
| Offered frame | YSS.1-50, ordinary 50 A frame |
|---|---|
| Original family frame references | YSS.1-18 / YSS.1-32 / YSS.1-50 / YSS.1-50h; full family tables remain in the complete PDF |
| Physical poles | 2P / 3P / 4P / 6P / 8P / 9P, according to the selected circuit |
| Original product-page voltage references | 800 V / 1000 V / 1200 V / 1500 V DC |
| Original product-page current range | 15–50 A across the listed family |
| Confirmed offering | 800–1400 V DC; only the exact combinations shown below |
| Higher-voltage supply applicability | To be confirmed |
| Standards | IEC/EN 60947-3; GB/T 14048.3 |
| Certificate-marking applicability | To be confirmed for the supplied product |
Confirmed voltage, current and circuit combinations
| Wiring | Physical poles | PV strings | Poles in series | Voltage | Current |
|---|---|---|---|---|---|
| 2P | 2P | 1 | 2 | 800V DC | 50A |
| 2P | 2P | 1 | 2 | 1000V DC | 50A |
| 2P | 2P | 1 | 2 | 1200V DC | 40A |
| 4P | 4P | 2 | 2 | 800V DC | 50A |
| 4P | 4P | 2 | 2 | 1000V DC | 50A |
| 4P | 4P | 2 | 2 | 1200V DC | 40A |
| 6P | 6P | 3 | 2 | 800V DC | 50A |
| 6P | 6P | 3 | 2 | 1000V DC | 50A |
| 6P | 6P | 3 | 2 | 1200V DC | 40A |
| 8P | 8P | 4 | 2 | 800V DC | 50A |
| 8P | 8P | 4 | 2 | 1000V DC | 50A |
| 8P | 8P | 4 | 2 | 1200V DC | 40A |
| 3P | 3P | 2 | 2 | 800V DC | 32A |
| 3P | 3P | 2 | 2 | 1000V DC | 25A |
| 3P | 3P | 2 | 2 | 1200V DC | 20A |
| 3T | 3P | 1 | 3 | 1200V DC | 50A |
| 3T | 3P | 1 | 3 | 1400V DC | 40A |
| 6T | 6P | 2 | 3 | 1200V DC | 50A |
| 6T | 6P | 2 | 3 | 1400V DC | 40A |
| 9T | 9P | 3 | 3 | 1200V DC | 50A |
| 9T | 9P | 3 | 3 | 1400V DC | 40A |
Use the complete wiring diagram for the selected arrangement. 2P / 4P / 6P / 8P provide one / two / three / four independent PV-string circuits with two poles in series. The 3P reference provides two strings and two poles in series as documented; follow its exact circuit. 3T / 6T / 9T provide one / two / three strings with three poles in series. The circuit codes 3T / 6T / 9T are distinct from the optional /T terminal-direction suffix.
Electrical characteristics
| Utilization category | DC-PV2 |
|---|---|
| Conventional free-air thermal current (Ith) | 50 A ordinary frame; 60 A reference applies only to the separate YSS.1-50h frame |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated short-time withstand current (Icw) | 1.5 kA for 1 s |
| Rated short-time making capacity (Icm) | 2.0 kA |
| Rated conditional short-circuit current (Icc) | 8 kA |
| Electrical cycles | 300 |
| Mechanical cycles | 10000 |
| Operating rate | 120 operations/h |
Installation and environment
| Mounting | Panel mounting |
|---|---|
| Terminal screws, M4 | 1.2–1.8 N·m |
| Panel mounting nut | 2.0–2.5 N·m |
| Knob screw, M3 | 0.5–0.7 N·m |
| Ambient temperature | −40 °C to +85 °C |
| Storage temperature | −40 °C to +85 °C |
| Relative humidity | 90% |
| Pollution degree | 2 |
| Terminal protection | IP20 |
| Panel protection | IP66, when assembled as documented |
| Conductor range | 14–8 AWG, stranded; 2.5–10.0 mm² |
| Dimensions | Complete pole-dependent body, panel cutout and shaft drawings are retained below |
Type designation and terminal layout
YSS identifies the family, 1 indicates panel mounting, and 50 identifies the ordinary frame. The pole or circuit code follows the frame designation. The optional /T suffix denotes wiring contacts in a different direction and a switch height 6.5 mm lower. This page offers the standard terminal layout; /T suffix and exact supplied appearance: To be confirmed. The complete document retains both dimension drawings.
Appearance and pole references
The first two gallery images retain the current original main angle and complete family photograph. Additional images are pole-configuration references directly extracted from the linked family PDF. Exact supplied model marking and image correspondence: To be confirmed.
2P document reference
3P and 3T document reference
6P and 6T document reference
8P document reference
9T document reference
Complete technical document
Download the complete YSS.1 family datasheet (1 wide PDF page / 2 printed pages)
The complete family document also contains YSS.1-18, YSS.1-32 and YSS.1-50h ratings and higher-voltage references. They are retained for full document context; only the confirmed ordinary-frame combinations above are selectable on this page.