NewTrend · Residential Energy Storage
Product overview
YER-HV3993 and YER-HV7833 are high-voltage rack-mounted LiFePO4 battery storage families for residential energy systems. Documented configurations use 1, 3, 6 or 10 packs, from 3.99kWh to 78.33kWh and 76.8V to 768V DC. The system design is intended for compatible on-grid, off-grid and hybrid inverter installations. Exact inverter compatibility and supplied certification applicability: To be confirmed.
Key features
- Automotive A-grade LiFePO4 cells; 52Ah and 102Ah families.
- Intelligent battery management system with software and hardware protection, monitoring and management.
- All-aluminum body design and natural cooling for heat dissipation.
- Rack-mounted modular construction for capacity expansion, standardized installation and operation.
- IP54 overall protection; CAN / RS485 communication.
- 5000 cycles for HV3993 and 6000 cycles for HV7833 at 0.2C, 80% DOD and 25±2°C.
Technical selection summary
YER-HV3993 — 52Ah series
| Parameter | YER-1HV3993 | YER-3HV3993 | YER-6HV3993 | YER-10HV3993 |
|---|---|---|---|---|
| Model | YER-1HV3993 | YER-3HV3993 | YER-6HV3993 | YER-10HV3993 |
| Number of battery packs | 1 | 3 | 6 | 10 |
| Rated energy | 3.99kWh | 11.97kWh | 23.95kWh | 39.93kWh |
| Cell specification | 52Ah LiFePO4 | |||
| Rated voltage | 76.8V DC | 230.4V DC | 460.8V DC | 768V DC |
| Charging temperature | 0°C to +55°C | |||
| Discharging temperature | −10°C to +55°C | |||
| Storage temperature | −20°C to +55°C; optimal 0°C to +35°C | |||
| Overall dimensions (W × D × H) | 500 × 610 × 1600mm | |||
| Pack dimensions (W × D × H) | 380 × 460 × 150mm | |||
| Continuous charge/discharge current | 26A | |||
| Maximum charge/discharge current | 52A | |||
| Cycle life | 5000 cycles at 0.2C, 80% DOD, 25±2°C | |||
| Communication | CAN / RS485 | |||
| Weight | 155kg | 225kg | 330kg | 470kg |
| Relative humidity | <95%, non-condensing | |||
| Protection level | IP54, overall unit | |||
| Cooling | Natural cooling | |||
| Altitude | <2000m | |||
| Standards | IEC 62619 / UN 38.3; supplied applicability to be confirmed | |||
YER-HV7833 — 102Ah series
| Parameter | YER-1HV7833 | YER-3HV7833 | YER-6HV7833 | YER-10HV7833 |
|---|---|---|---|---|
| Model | YER-1HV7833 | YER-3HV7833 | YER-6HV7833 | YER-10HV7833 |
| Number of battery packs | 1 | 3 | 6 | 10 |
| Rated energy | 7.83kWh | 23.49kWh | 46.98kWh | 78.33kWh |
| Cell specification | 102Ah LiFePO4 | |||
| Rated voltage | 76.8V DC | 230.4V DC | 460.8V DC | 768V DC |
| Charging temperature | 0°C to +55°C | |||
| Discharging temperature | −10°C to +55°C | |||
| Storage temperature | −20°C to +55°C; optimal 0°C to +35°C | |||
| Overall dimensions (W × D × H) | 600 × 860 × 1900mm | |||
| Pack dimensions (W × D × H) | 380 × 460 × 150mm | |||
| Continuous charge/discharge current | 51A | |||
| Maximum charge/discharge current | 102A | |||
| Cycle life | 6000 cycles at 0.2C, 80% DOD, 25±2°C | |||
| Communication | CAN / RS485 | |||
| Weight | 215kg | 335kg | 515kg | 755kg |
| Relative humidity | <95%, non-condensing | |||
| Protection level | IP54, overall unit | |||
| Cooling | Natural cooling | |||
| Altitude | <2000m | |||
| Standards | IEC 62619 / UN 38.3; supplied applicability to be confirmed | |||
Model suffixes identify pack quantity and energy family. Rated energy is not a guaranteed usable-energy value; operating reserve and inverter settings depend on the confirmed installation. Photographs illustrate the rack-mounted family and fully populated cabinets; no model-specific photo mapping is asserted. Supplied pack population, inverter interface, regional approvals and OEM warranty terms require confirmation.
Residential solar PV, storage and EV charging applications
The reference system is designed for an integrated residential solar PV, battery-storage and EV-charging installation. Battery voltage, current limits, communication protocol and protective devices must match the inverter and system design. Installation and commissioning require qualified personnel.