CNC Electric · YCB7-63N
Product overview
The CNC Electric YCB7-63N is a thermal-magnetic miniature circuit breaker for overload and short-circuit protection of AC distribution circuits. This page covers the original photographed single-pole C16 configuration: 16A, 230/400V AC, 50/60Hz and 6kA under IEC 60898-1. The handle and contact-status window provide a visible switching indication.
Technical selection summary
| Manufacturer model | YCB7-63N |
|---|---|
| Published configuration | 1P, 16A, C curve (C16) |
| Rated voltage / frequency on the product | 230/400V AC / 50/60Hz |
| Rated short-circuit capacity Icn | 6,000A under IEC/EN 60898-1 |
| Protection functions | Thermal overload, magnetic short-circuit protection and isolation |
| Standard | IEC/EN 60898-1 |
| Rated insulation voltage Ui | 500V |
| Instantaneous C-curve characteristic | 5–10 × rated current; see the original test table and curve |
| Mechanical / electrical life | 20,000 / 10,000 operations |
| Protection degree / pollution degree | IP20 / 2 |
| Reference ambient temperature | 30°C; apply the original temperature-current correction table |
| Operating ambient temperature | −5°C to +40°C; 24-hour average ≤35°C, 2024 catalogue |
| Relative humidity | ≤50% at +40°C; higher humidity permitted at lower temperature |
| Installation altitude | ≤2,000m |
| Terminal connection | Cable, pin-type or U-type busbar; maximum conductor/busbar capacity 25mm², original catalogue |
| Terminal tightening torque | 2N·m, original catalogue |
| Mounting | 35mm EN60715 DIN rail, fast-clip device |
| Single-pole dimensions | 17.8 ±0.2mm wide; use the original dimension drawing for the full mounting envelope |
Selection and installation
This item is the original 1P C16 AC version. Select the pole count, current and C-curve characteristic for the actual circuit and prospective fault current. The catalogue operating range −5°C to +40°C and terminal torque 2N·m are used here; the separate instructions state a wider ambient range and a maximum torque of 2.5N·m. Use top supply terminals, as required by the instructions, and follow the markings on the supplied unit. The catalogue Uimp row has an inconsistent printed unit, so it is not used as an independently verified rating on this page. This AC MCB is not for DC PV strings and provides no residual-current protection.
Typical applications
Single-pole residential, commercial and light-industrial AC distribution circuits requiring coordinated overload and short-circuit protection. Check starting current separately when protecting circuits supplying motors or other high-inrush loads.
Original technical data and drawings
The following manufacturer figures retain the original technical content. Dimensions are in millimetres unless otherwise marked. Refer to the model and frame labels when using a shared family drawing.
Download the complete original CNC YCB7-63N catalogue (PDF)
Download the complete original CNC YCB7-63N instructions (PDF)