NewTrend · adjustable enclosed AC/DC supplies
Product overview
The S-500-12 and S-600-12 provide a single adjustable 12V DC output for equipment and lighting circuits. The S-500-12 nameplate specifies 40A, while the S-600-12 specifies 50A. Both versions use a fan-cooled metal enclosure, screw terminals and separate voltage/current adjustment controls.
Technical selection summary
| S-500-12 DC output | 12V DC, 40A nameplate rating |
|---|---|
| S-600-12 DC output | 12V DC, 50A nameplate rating |
| AC input markings | 100–120V AC / 200–240V AC; use the applicable input range |
| AC input current markings | 6.6A / 3.3A respectively |
| Input frequency | 50/60Hz |
| Output | Single DC output; three positive and three negative terminal positions |
| Adjustment controls | Separate voltage and current adjustment controls |
| Voltage adjustment reference | Approximately ±10% |
| Protection functions | Overload, overvoltage, short circuit and overcurrent |
| Cooling | Built-in fan with ventilated metal enclosure |
| Dimensions, both versions | 212mm long × 113mm wide × 46mm high |
| Working temperature | −20°C to +70°C |
| Storage temperature | −40°C to +85°C |
| Ambient humidity | 0–95% RH, non-condensing |
| Wiring | L and N: AC input; PE: protective earth; +V and −V: DC output |
| Installation | Dry, ventilated electrical enclosure; protective-earth bonding required |
S-500-12 terminal connections
Connect the AC supply to L and N, and bond the PE terminal to protective earth. The three +V positions form the positive DC output group; the three −V positions form the negative output group. The illustrated 12V version has a 40A nameplate output. Two front adjustments control output voltage and current.
S-600-12 terminal connections
The S-600-12 uses the same terminal order with a 12V, 50A nameplate output. Match the AC source to the applicable 100–120V or 200–240V input marking before energizing. Use appropriate conductors and circuit protection for the connected load; do not treat multiple output terminals as separate isolated supplies.
Fan cooling and protection
The built-in fan and ventilation slots remove heat from the enclosed supply. Keep the fan path and terminal area unobstructed. Overload, overvoltage, short-circuit and overcurrent protection support normal equipment operation. The metal cover carries a high-voltage warning: isolate the AC input before wiring or servicing and do not remove the cover while energized.
S-500-12 dimensions
The enclosure measures 212 × 113 × 46mm. Allow additional space for wiring, the terminal cover and cooling airflow. Install in a dry location inside a suitable electrical enclosure.
S-600-12 dimensions
The S-600-12 shares the 212 × 113 × 46mm mounting envelope. Select the exact model for the required output current and keep the terminals accessible after installation.
Typical applications
For compatible 12V DC loads in industrial automation, instrumentation, communication equipment and lighting installations. Match voltage, continuous load current, ambient conditions and available mounting space to the selected supply.