Product overview
The LRS-350-24 is a low-profile, enclosed switching power supply with a 24V DC, 14.6A output marking and a nominal 350W power class. A side-mounted input-range selector accommodates the two marked AC supply ranges. The integral fan and ventilation openings dissipate heat from the 30mm-high metal enclosure.
Technical selection summary
| Model | LRS-350-24 |
|---|---|
| Nominal power | 350W |
| DC output | 24V DC, 14.6A |
| Input nameplate | 100–120V AC, 6.0A / 200–240V AC, 3.5A; 50/60Hz |
| Input selection | Manual AC range selector; set to the correct supply range before energizing |
| Voltage adjustment | +V ADJ; ±10% adjustment reference |
| Input terminals | L, N and PE protective earth |
| Output terminals | Three +V and three −V terminals |
| Cooling | Built-in temperature-controlled fan and ventilated metal enclosure |
| Protections | Overload, overvoltage, short circuit and overcurrent |
| Working temperature | −20°C to +70°C |
| Storage temperature | −40°C to +85°C |
| Ambient humidity | 0–95% RH, non-condensing |
| Dimensions | 215 × 115 × 30mm |
Terminals and output adjustment
The input terminals are labelled L, N and protective earth. The three +V terminals share the positive output and the three −V terminals share the negative output. Use the +V ADJ control to adjust the DC output within the stated adjustment range. Bond protective earth and select suitable conductors, external protection and an enclosure for the complete installation.
AC input-range selector
Check the available AC supply and set the side selector to the matching input range before power is applied. The nameplate marks 100–120V AC or 200–240V AC operation at 50/60Hz. The selector must not be changed while the supply is energized. Retain the high-voltage warning labels and disconnect input power before servicing.
Cooling, protection and installation
The built-in fan is controlled according to working temperature. Keep its inlet, outlet and enclosure ventilation slots clear. The supply includes overload, overvoltage, short-circuit and overcurrent protection, and the source specification states a full-load burn-in test. Install in a dry, non-condensing environment and allow sufficient airflow and service space around the case.
Dimensions and mounting
The case measures 215mm long × 115mm wide × 30mm high. The side views show the input selector and mounting features. Allow additional space for cable entry, terminal access and cooling airflow.
Typical applications
For compatible 24V DC automation, industrial-control, instrumentation, communication and lighting loads within the output rating. Check polarity and the selected AC input range before connecting the load.