People Electric · Travel Limit Switch
Product overview
People Electric LX19 travel switches provide mechanical stroke, motion-direction and speed-control inputs. The original selection table covers a contact component, a plunger and single/double-roller arrangements. Select the precise actuator and reset behaviour for the machine.
Technical selection summary
| Manufacturer / series | Original People Electric LX19 |
|---|---|
| Contact arrangement | 1NO + 1NC for all eight models in the original table |
| Control circuit | AC50Hz up to 380V; DC up to 220V |
| Current distinction | The series table lists a 5A basic value; the pictured LX19-001 identifies Ith 5A and separate operating duties. Do not treat 5A as a universal inductive breaking-current rating. |
| Pictured LX19-001 duties | AC-15: 380V / 0.8A; DC-13: 220V / 0.1A, as marked on the original LX19-001 photograph. Confirm the exact ordered model rating. |
| LX19K / LX19-001 | LX19K contact component: 1.5–3.5mm operation, ≥0.5mm overtravel, ≤10N force. LX19-001 rod/plunger with self-reset: 1.5–4mm operation, ≥3mm overtravel, ≤15N force. |
| Single-roller versions | LX19-111 / -121 / -131: operating angle ≤30°, force ≤20N; exact reset/roller arrangement must match the ordered version |
| Double-roller versions | LX19-212 / -222 / -232: U-shaped double-roller actuator, no self-reset; operating angle ≤60°, force ≤20N; roller positions differ by model |
| Mounting / dimensions | LX19K body drawing: 33mm width, 35mm height; mounting centres 24 × 21.6mm. Enclosed versions: 52mm maximum width, principal mounting centres 35 × 65mm; overall height/depth vary by actuator. See original drawings. |
| Environment | Altitude <2,000m; -5 to +40°C, daily average ≤35°C; RH ≤50% at +40°C; pollution degree III; installation category II |
| Standards stated by manufacturer | GB 14048.5; IEC 60947-5-1 |
Select the complete actuator model, including reset behaviour. The original transfer-time column is not restated as a numeric rating because its decimal notation is unclear. Confirm actual control-load duty, travel and installation dimensions; the pictured current duties are identified as a specific LX19-001 example.
Typical applications
- Mechanical stroke and end-position inputs in industrial control.
- Machine direction and speed-control sequences using the matching actuator.
Specify your enquiry
For a focused quotation, include:
- Exact LX19 component/actuator model, reset action and contact duty.
- Control voltage/load, required travel and replacement nameplate/photo.
- Mounting clearance, quantity and destination.
Download People Electric LX19 catalogue (PDF)