CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
  • Home
  • Products
    QOD2F 2 Space Flush Load Center

    Automation & Control

    QOD2F 2 Space Flush Load Center

    Circuit Breaker & Fuses

    QOD2F 2 Space Flush Load Center

    Din-Rail Mounted Products

    QOD2F 2 Space Flush Load Center

    Distribution Box & Cabinet

    QOD2F 2 Space Flush Load Center

    Load Center & Meter Bases

    QOD2F 2 Space Flush Load Center

    Solar PV Products

    QOD2F 2 Space Flush Load Center

    Electrical Accessories

    QOD2F 2 Space Flush Load Center

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
Search
Sold out
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
Click to enlarge
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
Home Electrical Accessories Others CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch
1.5kW 2HP 380V Water Pump VFD Inverter
1.5kW 2HP 380V Water Pump VFD Inverter
Back to products
DELIXI CDC19s Switching Capacitor AC Contactor
DELIXI CDC19s Switching Capacitor AC Contactor

CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch

Brand Name:Chint
Place of Origin:China
Model Number:NM1
Rated Frequency (Hz):50/60Hz
Breaking Capacity:20kA – 100kA
Rated Voltage:690V
Type:Moulded Case
Poles
Rated Current
Breaking Capacity (Icu @380V)
Selected Model:
SKU: 1600725994755 Category: Others
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Chint original NM1 molded case circuit breaker is suitable for power distribution and for protecting circuits against overload, short-circuit, and under-voltage conditions. It can also be applied to infrequent motor starting and to motor overload, short-circuit, and under-voltage protection.

Electrical ratings: AC 690V, 50Hz/60Hz, 10A – 1250A.

Pole configuration shown on this page: 3 Pole / 4 Pole. Breaking capacity shown on this page: 25kA / 50kA / 65kA.

Technical Specifications

Parameter Specification
Model Series NM1
Type Molded Case Circuit Breaker (MCCB)
Rated Frequency 50Hz / 60Hz
Rated Voltage 690V AC
Rated Current 10A – 1250A
Pole Configuration 3 Pole / 4 Pole
Breaking Capacity 25kA / 50kA / 65kA
Standard IEC/EN 60947-2

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A

Poles

2P, 3P, 4P

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for CHINT NM1-125S/3300 Plastic Case Circuit Breaker Air Switch.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Trip Unit Protection

How to choose between Thermal-Magnetic (TMD) and Electronic (Micrologic) trip units?

A

Thermal-magnetic trip units provide fixed or adjustable bimetallic overload and electromagnetic instantaneous short-circuit protection, ideal for standard industrial power distribution. Electronic microprocessor trip units offer precise digital dials for L (Long-time delay overload), S (Short-time delay short-circuit), I (Instantaneous short-circuit), and G (Ground-fault protection), delivering total time-current selectivity in modern switchgear.

Ics vs Icu Capacity

What is the technical distinction between Ultimate (Icu) and Service (Ics) breaking capacity?

A

Icu represents the absolute maximum fault current the breaker can safely interrupt, after which inspection or replacement may be needed. Ics represents the operational breaking capacity (50%, 75%, or 100% of Icu) that the breaker can clear repeatedly and remain fully operational without performance degradation. In critical healthcare, data center, and continuous industrial applications, specify breakers with Ics = 100% Icu.

3P vs 4P Neutral

When should a 4-Pole (4P) MCCB be specified instead of a standard 3-Pole (3P) MCCB?

A

A 4P breaker with a switched neutral is required in systems with dual power sources (generator / utility ATS transfer) to prevent circulating neutral currents, in IT distribution networks, and in commercial installations with heavy non-linear harmonic loads (LED drivers, variable speed drives) where neutral conductor current can exceed phase currents.

Motorized & Remote Operation

How to select manual rotary handles vs motorized electric operating mechanisms?

A

Direct or extended door rotary handles are specified when the MCCB is enclosed inside switchgear cubicles, providing padlocking and door-interlock safety. Motor operating mechanisms (electric operators) are required for automated SCADA control, remote PLC open/close operations, and automatic transfer switch (ATS) integration.

Terminal & Mounting Options

What terminal connection hardware and mounting configurations are available?

A

Standard front connection lugs accept copper or aluminum compression terminals and busbar connections. For high-density panel boards, extended spreader terminals, rear connection studs, and plug-in / draw-out base cassettes are available to facilitate rapid maintenance and modular swap-out.

Related products

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC66P
Phase:1
Main Circuit Rating Current:200A
750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
THQL2145 2-Pole 45A 120V/240V 10kA Q-Line Circuit Breaker
THQL2145 2-Pole 45A 120V/240V 10kA Q-Line Circuit Breaker

THQL2145 2-Pole 45A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:100V,220V,230V,240V
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options
LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options

LC2K06 3P 6A AC Reversing Contactor Multiple Coil Options

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC2K06
Phase:3
Main Circuit Rating Current:6A
type:Reversing contactor
Certificate:CE, ROHS
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K LP1K
Phase:3
Main Circuit Rating Current:6A 9A 12A 16A
type:Magnetic contactor
CA10 LW26 32A 3-Position Power Transfer Changeover Cam Switch
CA10 LW26 32A 3-Position Power Transfer Changeover Cam Switch

CA10 LW26 32A 3-Position Power Transfer Changeover Cam Switch

Whether the smart:NO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Max. Current:32A
Mechanical Life:100000
Model Number:LW26-32
Max. Voltage:220V,240V,380V
IP level:IP41
Certification:CE
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A
LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

LP1K 24VDC Coil Mini DC Contactor 6A/9A/12A

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K
Phase:3
type:Magnetic contactor
Certificate:CE, ROHS
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A
600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

600V-1000V High Voltage EV Relay HV DC Contactor 50A-600A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • DZ47-63 C45N 5kA IEC60898 C-Curve MCB 35mm DIN Rail DZ47-63 C45N 5kA IEC60898 C-Curve MCB 35mm DIN Rail
  • DELIXI JDT50E Warning Light DELIXI JDT50E Warning Light
  • CHINT NH40-250 4P 250A Auto Changeover Switch ATS CHINT NH40-250 4P 250A Auto Changeover Switch ATS
  • DELIXI CDW3 Controller of Transfer Switching Equipment DELIXI CDW3 Controller of Transfer Switching Equipment
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...