Chint JSZ6 Time Delay Relay Chint JSZ6 Time Delay Relay
  • Home
  • Products
    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Automation & Control

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Circuit Breaker & Fuses

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Din-Rail Mounted Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Distribution Box & Cabinet

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Load Center & Meter Bases

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Solar PV Products

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Electrical Accessories

    CHINT AX-X1 Auxiliary Contact for NXB-63 / NXB-40 MCB Accessories

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint JSZ6 Time Delay Relay Chint JSZ6 Time Delay Relay
Search
Chint JSZ6 Time Delay Relay
Click to enlarge
Home Chint Electrical Materials Chint Relays Chint JSZ6 Time Delay Relay
Chint NJYB3 Voltage Protection Relay
Chint NJYB3 Voltage Protection Relay
Back to products
Chint NJS5-M2 Time Relay
Chint NJS5-M2 Time Relay

Chint JSZ6 Time Delay Relay

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:JSZ6-2 JSZ6-4
Contact Load:High Power
Protect Feature:Sealed
Time Range
Supply Voltage
Delay Function
SKU: 1769743124139089920 Category: Chint Relays
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

Chint original JSZ6 JSZ6-2 2 Changeover JSZ6-4 4 Changeover 5s 10s 30s 60s 24V 220V 380V Time Delay Relay

   

General
JSZ6 Time Delay Relay is applicable for automatic control system, such as machine tool automatic control, complete equipment automatic control. Etc. 

General
JSZ6 Time Delay Relay is applicable for automatic control system, such as machine tool automatic control, complete equipment automatic control. Etc. 

 

General
JSZ6 Time Delay Relay is applicable for automatic control system, such as machine tool automatic control, complete equipment automatic control. Etc. 

Additional information
Time Range

0.1-1s, 1-10s, 0.1-10s, 1-60s, 0.1-6min, 1-6min, 1-60min, 1-10h

Supply Voltage

AC 24V, AC 220V, AC 380V, DC 24V

Delay Function

On-Delay, Off-Delay, Cycle, Star-Delta

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Chint JSZ6 Time Delay Relay.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Chint NJB1-X Voltage Protection Relay
Chint NJB1-X Voltage Protection Relay

Chint NJB1-X Voltage Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NJB1-X
Contact Load:High Power
Protect Feature:Sealed
Chint JSS48A Time Delay Relay
Chint JSS48A Time Delay Relay

Chint JSS48A Time Delay Relay

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:JSS48A
Contact Load:High Power
Protect Feature:Sealed
Chint JZX-22F Miniature Relay
Chint JZX-22F Miniature Relay

Chint JZX-22F Miniature Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:JZX-22F
Contact Load:High Power
Protect Feature:Sealed
Chint NJBK7 Motor Protection Relay
Chint NJBK7 Motor Protection Relay

Chint NJBK7 Motor Protection Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:PROTECTIVE
Model Number:NJBK7-800
Contact Load:High Power
Protect Feature:Sealed
Chint NKG3 Time Switch
Chint NKG3 Time Switch

Chint NKG3 Time Switch

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:NKG3 NKG3-M
Contact Load:High Power
Protect Feature:Sealed
Chint JSZ3 Time Delay Relay
Chint JSZ3 Time Delay Relay

Chint JSZ3 Time Delay Relay

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:JSZ3
Contact Load:High Power
Protect Feature:Sealed
Chint KG10D Time Switch

Chint KG10D Time Switch

Size:Miniature
Brand Name:Chint
Theory:Time Relay
Place of Origin:China
application:General Purpose
Model Number:KG10D
Contact Load:High Power
Protect Feature:Sealed
Chint Miniature High-Power Electromagnetic Relay

Chint Miniature High-Power Electromagnetic Relay

Size:Miniature
Brand Name:Chint
Theory:Electromagnetic Relay
Place of Origin:China
application:General Purpose
Model Number:JQX-13F
Contact Load:High Power
Protect Feature:Sealed
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NJBK7 Motor Protection Relay Chint NJBK7 Motor Protection Relay
  • Chint JD-8 Integrated Motor Protector Chint JD-8 Integrated Motor Protector
  • Chint JZX-22F Miniature Relay Chint JZX-22F Miniature Relay
  • Chint JSS48A Time Delay Relay Chint JSS48A Time Delay Relay
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the car.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...