DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
Search
DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
Click to enlarge
DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
Home Din-Rail Mounted Products RCBO DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker
1600A-3000A Heavy Duty SPST NO DC Contactor
1600A-3000A Heavy Duty SPST NO DC Contactor
Back to products
SW500 AMETEK Equivalent Magnetic Latching DC Contactor
SW500 AMETEK Equivalent Magnetic Latching DC Contactor

DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ30LE
Type:Earth Leakage
Tripping Curve
Residual Current
SKU: 1770408942652891136 Category: RCBO
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

DZ30LE-32 DZ30LE-63 1P+N RCBO 6A 10A 16A 20A 25A 32A 40A 63A 80A 100A 30mA 100mA 300mA DZ30LE DPN RCBO

 

1.Application

DZ30LE-32 is used in the single phase circuit of AC 50Hz/60Hz, rated voltage 230V, used as electron shock protection. It can protect circuit form overload and short circuit. This product has advantages of small volume, high breaking capacity, live and zero wire are cut off at the same time, also protecting person from electric shock when the live wire connected opposite. It conforms with the standards of IEC61009.

2. Main Technical Parameter

Type DZ30LE-32
Pole 1P+N
Rated current (A) 6,10,16,20,25,32,40,50,63,80,100A
Rated voltage(V) 230
Rated residual action current In(A) 30mA, 100mA, 300mA
Rated residual non-action current Ino(A) 0.015
Rated residual making/breaking capacity Im(A) 500
Type of instantaneous release C
Rated making/breaking capacity Im(A) 4500

3. Applicable conducting wire:

Rated current(A) Norminal cross section of wire mm2
In ≤ 6 1
6< In ≤ 13 1.5
13 < In ≤ 20 2.5
20 < In ≤ 25 4
25 < In ≤ 32 6

4. Residual current breaking time

In (A) In (A) Breaking time(s) when equals to rating following
In 2In 5In 5,10,20,50,100,200,500a(A) Itb
6-32 0.03 0.1 0.06 0.04 0.04 0.04

5. The over-current protection property

Ambient Temperature Initial Status Test Current Expected Result Expected Result Note
  Cold position 1.13In t ≥ 1h Non-release –
30±2oC Carried out immediately after previous test 1.45In t<1h Release –
  Cold position 2.55In 1s < t < 60s Release Current smoothly rises to specified value within 5s
-5~+40oC Cold position 5In t ≥ 0.1s Non-release Type C
Cold position 10In t < 0.1s Release Type C

6. Dimension

Additional information
Residual Current

30mA, 100mA, 300mA

Tripping Curve

B, C, D

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for DZ30LE-32/63 1P+N RCBO 30-300mA Residual Breaker.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Voltage & Load Sizing

How to verify rated operational voltage, frequency, and load duty cycle?

A

Verify that the nominal line voltage (AC 230V single-phase or 400V/415V/690V three-phase at 50/60Hz, or DC voltage ratings) falls within the continuous maximum operating limits of the device. Check duty cycle ratings (continuous vs intermittent duty) to ensure thermal stability under full load.

Protection & Environment

What ingress protection (IP Rating) and environmental enclosures are recommended?

A

For clean indoor electrical rooms, standard IP20 modular DIN-rail housings are recommended. For outdoor, industrial washdown, or dusty environments, mount components inside weatherproof enclosures rated IP65/IP66 with UV-resistant polycarbonate or powder-coated steel enclosures equipped with compression cable glands.

Selectivity & Grading

How to ensure upstream and downstream coordination in power distribution boards?

A

Ensure proper discrimination by grading current thresholds and tripping time delays: upstream devices should have higher current ratings and intentional short-time delays (Class S), allowing downstream branch MCBs to clear localized faults without blacking out the entire facility.

Installation & Mounting

What mounting rails, busbars, and spatial clearances are required?

A

Components mount on standard symmetrical 35mm DIN rail (EN 60715 / TH35-7.5) or backplate screw fixings. Maintain recommended top/bottom ventilation gaps (typically 30–50mm) to ensure unrestricted air convection, and use standard pin/fork comb busbars to minimize contact resistance and wiring errors.

Conductor & Torque Sizing

What conductor sizes and terminal tightening torques should be applied?

A

Select copper or aluminum conductor cross-sections complying with IEC 60364-5-52 current-carrying capacity tables based on continuous load. Always use a calibrated torque screwdriver or torque wrench to tighten terminal screws to the manufacturer-specified torque to prevent hot-spot degradation and loose connections.

Related products

Combined RCBO 2P 10A-40A 6kA/10kA ESV SAA Cert

Combined RCBO 2P 10A-40A 6kA/10kA ESV SAA Cert

BCD Curve:C
Type:RCBO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:RCBO-2P
Breaking Capacity:6kA, 10kA
Rated Voltage:230V, 415V
Type:Residual Current
Type1:Magnectic or Electronic
Type2:AC type or A type
Poles Number:1P+N
DZ47LE RCD Residual Current Breaker 1P+N to 4P
DZ47LE RCD Residual Current Breaker 1P+N to 4P

DZ47LE RCD Residual Current Breaker 1P+N to 4P

BCD Curve:C
Type:RCCB
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ47LE-100
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:220V,400V ,230V,240V,380V
Type:Earth Leakage
Sold out
Single Pole Switched Neutral DPN RCBO 6kA/10kA

Single Pole Switched Neutral DPN RCBO 6kA/10kA

BCD Curve:C
Type:RCBO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:NTL11-63
Breaking Capacity:6kA
Rated Voltage:220V
Type:Residual Current
Poles Number:1P+N
NC100LE DZ47LE-125 2P/3P/4P RCBO Residual Breaker
NC100LE DZ47LE-125 2P/3P/4P RCBO Residual Breaker

NC100LE DZ47LE-125 2P/3P/4P RCBO Residual Breaker

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ47LE-125
Rated voltage:230/400V
Standard:IEC/EN 61009-1
Breaking capacity:6KA
DZ47LE-63 Residual Current Device RCD 230/400V
DZ47LE-63 Residual Current Device RCD 230/400V

DZ47LE-63 Residual Current Device RCD 230/400V

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ47LE-63
Type:Earth Leakage
Sold out
1P+N DPN RCBO 18mm Width Type B & C 6kA Breaker

1P+N DPN RCBO 18mm Width Type B & C 6kA Breaker

BCD Curve:C
Type:RCBO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LKE1 / LKE2 / LKE3
Breaking Capacity:6kA
Rated Voltage:220V
Poles Number:Twin
Type:Residual Current
JVR016 AVDT-63M Type A/AC RCBO 1P+N 20-300mA
JVR016 AVDT-63M Type A/AC RCBO 1P+N 20-300mA

JVR016 AVDT-63M Type A/AC RCBO 1P+N 20-300mA

BCD Curve:C
Type:RCBO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:JVR016-32
Rated Frequency (Hz):50/60Hz
Breaking Capacity:6kA
Rated Voltage:240V
Type:Residual Current
Type2:AC type or A type
Rated current:6, 10, 16, 20, 25, 32A
Poles Number:1P+N
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • 1P+N DPN RCBO 18mm Width Type B & C 6kA Breaker 1P+N DPN RCBO 18mm Width Type B & C 6kA Breaker
  • Single Pole Switched Neutral DPN RCBO 6kA/10kA Single Pole Switched Neutral DPN RCBO 6kA/10kA
  • NC100LE DZ47LE-125 2P/3P/4P RCBO Residual Breaker NC100LE DZ47LE-125 2P/3P/4P RCBO Residual Breaker
  • JVR016 AVDT-63M Type A/AC RCBO 1P+N 20-300mA JVR016 AVDT-63M Type A/AC RCBO 1P+N 20-300mA
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...