120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit 120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit
  • Home
  • Products
    Automation & Control product category

    Automation & Control

    Circuit Breakers & Fuses product category

    Circuit Breaker & Fuses

    DIN-Rail Mounted Products category

    Din-Rail Mounted Products

    Distribution Box & Cabinet category

    Distribution Box & Cabinet

    Load Center & Meter Bases category

    Load Center & Meter Bases

    Solar PV Products category

    Solar PV Products

    Electrical Accessories category

    Electrical Accessories

    Chint Electrical Materials category

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit 120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit
Search
120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit
Click to enlarge
Home Din-Rail Mounted Products Surge Protector SPD 120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit
AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch
AHC 1/2 Channel Weekly Programmable DIN Rail Time Switch
Back to products
THC Weekly Programmable DIN Rail LCD Digital Timer Switch
THC Weekly Programmable DIN Rail LCD Digital Timer Switch

120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit

Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:Y5-120
Type:Type 1+2
Class:T1+T2
Wave:8/20μs and 10/350μs
Imax (8/20μs):120KA
Iimp (10/350μs):12.5KA
SKU: 1770410020484161536 Category: Surge Protector SPD
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

120KA Surge Suppressor Citel type 36mm width Surge Protective Device 275V 380V 420V 550V T2 and T1 Type 1+2 Surge Protector

 

1) Voltage limmiting type design, integrated structure, conforms to the T1 and T2 test conditions.
2) Three pieces and four pieces of combination, achieve common mode protection mode.
3) High level of protection, freewheeling breaking ability, large flow capacity.
4) Alarm contact, realize remote communication function.
5) A high level of protection, free wheeling, large flow capacity.
6) Standard 35mm track design, convenient installation.

 

Model Y5-120 Y5-160
Quantity of electric charge (Q) 6.25As  25As
Nominal discharge current (In)  60KA (8/20μs) 100KA (8/20μs)
Max discharge current (Imax) 120KA (8/20μs) 160KA (8/20μs)
The impact of discharge current (Iimp) 12.5KA (10/350μs) 12.5KA (10/350μs)
Max continuous operating voltage (Ucpv) 275V 320V 385V 420V 550V 275V 320V 385V 420V 550V
Voltage protection level (Up) <1.8KV  <2.0KV <2.5KV <3.0KV <3.5KV <2.0KV <2.5KV <3.0KV <3.5KV <3.8KV
Type Type 1 & Type 2 (T1 + T2), 8/20μs and 10/350μs surge protection
rated operational voltage (Uopv) 220V~690V
combination method 3+0, 4+0
local indiction green indicates normal state and red indicates failure.
Protection class of body IP20
capcity of connection 4~35mm²
Installation 35mm Din Rail

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for 120kA Type 1+2 Surge Protector SPD w/ Alarm Circuit.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Voltage & Load Sizing

How to verify rated operational voltage, frequency, and load duty cycle?

A

Verify that the nominal line voltage (AC 230V single-phase or 400V/415V/690V three-phase at 50/60Hz, or DC voltage ratings) falls within the continuous maximum operating limits of the device. Check duty cycle ratings (continuous vs intermittent duty) to ensure thermal stability under full load.

Protection & Environment

What ingress protection (IP Rating) and environmental enclosures are recommended?

A

For clean indoor electrical rooms, standard IP20 modular DIN-rail housings are recommended. For outdoor, industrial washdown, or dusty environments, mount components inside weatherproof enclosures rated IP65/IP66 with UV-resistant polycarbonate or powder-coated steel enclosures equipped with compression cable glands.

Selectivity & Grading

How to ensure upstream and downstream coordination in power distribution boards?

A

Ensure proper discrimination by grading current thresholds and tripping time delays: upstream devices should have higher current ratings and intentional short-time delays (Class S), allowing downstream branch MCBs to clear localized faults without blacking out the entire facility.

Installation & Mounting

What mounting rails, busbars, and spatial clearances are required?

A

Components mount on standard symmetrical 35mm DIN rail (EN 60715 / TH35-7.5) or backplate screw fixings. Maintain recommended top/bottom ventilation gaps (typically 30–50mm) to ensure unrestricted air convection, and use standard pin/fork comb busbars to minimize contact resistance and wiring errors.

Conductor & Torque Sizing

What conductor sizes and terminal tightening torques should be applied?

A

Select copper or aluminum conductor cross-sections complying with IEC 60364-5-52 current-carrying capacity tables based on continuous load. Always use a calibrated torque screwdriver or torque wrench to tighten terminal screws to the manufacturer-specified torque to prevent hot-spot degradation and loose connections.

Related products

Sold out
40kA AC SPD T2 Class 2 Surge Protector 275V-420V

40kA AC SPD T2 Class 2 Surge Protector 275V-420V

Type:T2
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:YJ1-C (SNT1-C40)
Rated Voltage:285V 420V
Max Discharge current:40 A
Imax (8/20μs):40KA
Sold out
Class 2 Type 2 AC Surge Protective Device SPD 100kA

Class 2 Type 2 AC Surge Protective Device SPD 100kA

Type:T2
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:Y1-B 100KA
Rated Voltage:385V
Max Discharge current:100 A
Type:Type 2 (T2)
Class:Class 2 (T2)
Wave:8/20μs
Imax (8/20μs):100KA
160kA Type 1+2 Surge Protective Device w/ Alarm

160kA Type 1+2 Surge Protective Device w/ Alarm

Type:T1+T2
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:Y5-160
Rated Voltage:275V/320V/385V/420V/550V
Max Discharge current:120 A
Type:Type 1+2
Class:T1+T2
Wave:8/20μs and 10/350μs
Imax (8/20μs):160KA
Iimp (10/350μs):12.5KA
40kA DC SPD Surge Protector 2P/3P 500V-1500V Solar

40kA DC SPD Surge Protector 2P/3P 500V-1500V Solar

Type:T2
Brand Name:Newtrend
Place of Origin:China
Model Number:YJ1-C40
Rated Voltage:500V, 800V, 1000V, 1200V, 1500Vdc
Max Discharge current:40 A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • 40kA DC SPD Surge Protector 2P/3P 500V-1500V Solar 40kA DC SPD Surge Protector 2P/3P 500V-1500V Solar
  • 160kA Type 1+2 Surge Protective Device w/ Alarm 160kA Type 1+2 Surge Protective Device w/ Alarm
  • Class 2 Type 2 AC Surge Protective Device SPD 100kA Class 2 Type 2 AC Surge Protective Device SPD 100kA
  • 40kA AC SPD T2 Class 2 Surge Protector 275V-420V 40kA AC SPD T2 Class 2 Surge Protector 275V-420V
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the plane.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...