People Electric · Motor Soft Starter
Product overview
People Electric RDJR6 soft starters use controlled thyristors and microprocessor control to regulate AC asynchronous-motor starting and stopping. The manufacturer provides a discrete 5.5–320kW model range, matching rated currents, external-control terminals and bypass application diagrams.
Technical selection summary
| Manufacturer / series | Original People Electric RDJR6 |
|---|---|
| Supply shown in application diagrams | Three-phase AC380V, 50Hz |
| Motor power / rated current | 5.5kW / 11A; 7.5kW / 15A; 11kW / 22A; 15kW / 30A; 18.5kW / 37A; 22kW / 44A; 30kW / 60A; 37kW / 74A; 45kW / 90A; 55kW / 110A; 75kW / 150A; 90kW / 180A; 115kW / 230A; 132kW / 264A; 160kW / 320A; 185kW / 370A; 200kW / 400A; 250kW / 500A; 280kW / 560A; 320kW / 640A |
| Starting / stopping | Thyristor phase control with soft-start, soft-stop and free-stop functions |
| Indication | Digital display, ready/running/fault indication and external control terminals |
| Protection functions | Phase loss, overvoltage, overload, overcurrent and overheating protection, subject to commissioning settings |
| Relay outputs | Bypass, programmable and fault outputs; catalogued NO contact rating AC250V / 5A |
| Analogue output | 0–20mA motor-current monitoring output |
| Bypass arrangement | External bypass contactor shown in manufacturer diagrams; above 75kW, an intermediate relay is required to drive its coil |
| 5.5–55kW mounting group | A/B/C: 145/278/165mm; D/E: 132/250mm; M6; 3.7kg |
| 75–200kW mounting group | A/B/C: 260/530/205mm; D/E: 196/380mm; M8; 18kg |
| 250–320kW mounting group | A/B/C: 290/570/260mm; D/E: 260/470mm; M8; 25kg |
Select motor power together with the motor nameplate current and starting duty. The standard installed-type models are listed here; cabinet construction and auxiliaries require confirmation. Final selection and commissioning must consider load torque, start frequency, bypass contactor and protection coordination. Obtain the current parameter-setting instructions for the supplied controller.
Typical applications
- Soft starting and stopping of AC asynchronous-motor driven equipment, after checking motor and driven-load requirements.
Specify your enquiry
For a focused quotation, include:
- Motor rated power/current, supply voltage/frequency and driven-load type.
- Starting frequency, starting time, bypass contactor and control arrangement.
- Installed unit or cabinet requirement, mounting constraints, quantity and destination.
Download People Electric RDJR6 catalogue (PDF)