Product overview
NewTrend X photovoltaic extension cable assemblies are rated 1500V DC, with 4mm², 6mm² and 10mm² conductor options. The 18 part numbers distinguish cable size, black or red insulation and male-female, male or female terminal configurations. Current-carrying capacities at 60°C are 20A, 35A and 63A respectively. Cable length is specified by the required L dimension.
Technical selection summary
| Rated voltage | 1500V DC |
|---|---|
| Conductor cross-sections | 4mm² / 6mm² / 10mm² |
| Current-carrying capacity at 60°C | 4mm²: 20A; 6mm²: 35A; 10mm²: 63A |
| Cable colors | Black or red |
| Terminal configurations | Male + female, male or female |
| Length | L in the part number and outline drawing denotes cable length; specify required length |
| Connector references | V005 / SPV-002 for 4/6mm²; SPV-002-10 for 10mm² |
| Cable reference | V1500DC |
| X-MF-40B-L | 4mm² Black; 20A at 60°C; Male + female; V005/SPV-002 |
| X-MF-40R-L | 4mm² Red; 20A at 60°C; Male + female; V005/SPV-002 |
| X-MF-60B-L | 6mm² Black; 35A at 60°C; Male + female; V005/SPV-002 |
| X-MF-60R-L | 6mm² Red; 35A at 60°C; Male + female; V005/SPV-002 |
| X-MF-100B-L | 10mm² Black; 63A at 60°C; Male + female; SPV-002-10 |
| X-MF-100R-L | 10mm² Red; 63A at 60°C; Male + female; SPV-002-10 |
| X-M-40B-L | 4mm² Black; 20A at 60°C; Male; V005/SPV-002 |
| X-M-40R-L | 4mm² Red; 20A at 60°C; Male; V005/SPV-002 |
| X-M-60B-L | 6mm² Black; 35A at 60°C; Male; V005/SPV-002 |
| X-M-60R-L | 6mm² Red; 35A at 60°C; Male; V005/SPV-002 |
| X-M-100B-L | 10mm² Black; 63A at 60°C; Male; SPV-002-10 |
| X-M-100R-L | 10mm² Red; 63A at 60°C; Male; SPV-002-10 |
| X-F-40B-L | 4mm² Black; 20A at 60°C; Female; V005/SPV-002 |
| X-F-40R-L | 4mm² Red; 20A at 60°C; Female; V005/SPV-002 |
| X-F-60B-L | 6mm² Black; 35A at 60°C; Female; V005/SPV-002 |
| X-F-60R-L | 6mm² Red; 35A at 60°C; Female; V005/SPV-002 |
| X-F-100B-L | 10mm² Black; 63A at 60°C; Female; SPV-002-10 |
| X-F-100R-L | 10mm² Red; 63A at 60°C; Female; SPV-002-10 |
Typical applications
- Photovoltaic cable connections between solar panels and inverters
- Rooftop, ground-mounted and portable photovoltaic installations
View or download X PV extension cable original catalogue and selection table (PDF)
Product reference images and drawings
Select the complete part number and specify the required cable length L. Current values apply at 60°C. Connector configuration follows the selected reference. Installation and wiring must be performed by qualified electricians.