NewTrend · DC EV Charging
Product overview
DC-F provides simultaneous DC charging for up to four electric vehicles, with documented power configurations from 120 to 480 kW. The floor-standing unit supports commercial fleets, public charging hubs and highway service stations.
Intelligent charging and protection
- Ring charging-power distribution with dynamic sharing.
- Radar sensing wakes the screen as a user approaches and enters sleep mode after departure.
- Tipping detection triggers an alarm following collision or abnormal tilt.
- Internal temperature sensing reduces performance when required to protect components.
- High conversion efficiency, low standby consumption, connected operation and manual / vehicle protection.
Model and electrical input
| Model | Rated power | AC input current | Maximum weight |
|---|---|---|---|
| DC120-F | 120 kW | 204 A | ≤380 kg |
| DC150-F | 150 kW | 228 A | ≤395 kg |
| DC160-F | 160 kW | 244 A | ≤400 kg |
| DC180-F | 180 kW | 274 A | ≤415 kg |
| DC200-F | 200 kW | 304 A | ≤430 kg |
| DC210-F | 210 kW | 320 A | ≤435 kg |
| DC240-F | 240 kW | 365 A | ≤450 kg |
| DC270-F | 270 kW | 411 A | ≤465 kg |
| DC280-F | 280 kW | 426 A | ≤470 kg |
| DC320-F | 320 kW | 587 A | ≤500 kg |
| DC330-F | 330 kW | 502 A | ≤505 kg |
| DC360-F | 360 kW | 547 A | ≤520 kg |
| DC400-F | 400 kW | 608 A | ≤535 kg |
| DC440-F | 440 kW | 669 A | ≤550 kg |
| DC480-F | 480 kW | 730 A | ≤565 kg |
Four-outlet connector configuration
The selectable connector family is a four-outlet configuration using CCS1, CCS2, GB/T or NACS. Exact mixed-connector arrangement and complete ordering suffix: To be confirmed. Each of the four outlets may use the documented connector families; mixed arrangements can be specified before supply.
| Charging outlets | Four, A + B + C + D |
|---|---|
| CCS1 / CCS2 / GB/T / NACS output voltage | 150–1000 V DC |
| CCS1 / CCS2 / GB/T / NACS output current | 0–250 A |
| Cable length | 5 m |
| AC input voltage | 380–415 V AC, 3P + N + PE |
| Input frequency | 50 / 60 Hz |
| Standby consumption | ≤24 W |
| Efficiency | ≥95% |
| Power factor | ≥0.99 at 100% load |
Construction and controls
| Cabinet | Steel; galvanized-sheet document reference |
|---|---|
| Dimensions, L × W × H | 800 × 900 × 1900 mm |
| Packing dimensions, L × W × H | 1050 × 1250 × 2160 mm |
| Installation | Floor-stand |
| Cable routing | Bottom inlet / upper outlet |
| Display | Two LCD displays; exact supplied size: To be confirmed |
| Authorization | RFID / App |
| User interface | Emergency stop, LED indicator, card swiping and touch-screen control |
| Network | Ethernet / 4G / WiFi |
| OCPP | OCPP 1.6J; optional OCPP 2.0 / 2.0.1 applicability: To be confirmed |
| ISO15118-2 / ISO15118-20 | Optional; supplied configuration: To be confirmed |
Environment and protection
| Application | Indoor / outdoor |
|---|---|
| Working altitude | <2000 m |
| Working temperature | −30 °C to +50 °C |
| Storage temperature | −30 °C to +85 °C |
| Humidity | 5–95% |
| Protection | IP55; IK10 cabinet / IK08 display |
| Cooling | Forced-air |
| Protection functions | Overvoltage, undervoltage, overload, leakage current, grounding, overtemperature and lightning-surge protection |
| Warranty | 36-month original-page reference; supplied terms: To be confirmed |
| Certification references | CE, CB, TUV and RoHS; exact model / market / supplied OEM applicability: To be confirmed |
Charging standards
EN IEC 61851-1:2019; IEC 61851-1:2017; EN 61851-23:2014; IEC 61851-23:2014; EN 61851-24:2014; IEC 61851-24:2014; EN IEC 61000-6-2:2019; EN IEC 61000-6-4:2019; EN IEC 61851-21-2:2021.
Radio-frequency reference
| LTE-FDD bands | B1 / B2 / B3 / B4 / B5 / B7 / B8 / B12 / B13 / B18 / B19 / B20 / B25 / B26 / B28 |
|---|---|
| LTE-TDD bands | B38 / B39 / B40 / B41 |
| UMTS bands | B1 / B2 / B4 / B5 / B6 / B8 / B19 |
| MIFARE frequency | 13.56 MHz ±7K as printed; exact tolerance unit: To be confirmed |
| WiFi frequency | 2412–2484 MHz |
| WiFi maximum transmit power | 20.5 dBm |
| WCDMA maximum transmit power | 24 dBm +1 / −3 dB |
| LTE-FDD / LTE-TDD maximum transmit power | 23 dBm ±2 dB |
| MIFARE maximum transmit power | 14.05 dBuA/m |
Product features and application
Complete family technical document
Download the complete eight-spread technical document
All fourteen numbered pages and cover panels are retained. Additional document-only DC300-F and CHAdeMO references are not selectable configurations on this page.