Single Phase LCD RS485 KWH Power Meter 32A/40A Single Phase LCD RS485 KWH Power Meter 32A/40A
  • Home
  • Products
    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Automation & Control

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Circuit Breaker & Fuses

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Din-Rail Mounted Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Distribution Box & Cabinet

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Load Center & Meter Bases

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Solar PV Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Electrical Accessories

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Single Phase LCD RS485 KWH Power Meter 32A/40A Single Phase LCD RS485 KWH Power Meter 32A/40A
Search
Single Phase LCD RS485 KWH Power Meter 32A/40A
Click to enlarge
Home Din-Rail Mounted Products Din Rail Energy Meter Single Phase LCD RS485 KWH Power Meter 32A/40A
DELIXI CDZ9 Series Small Electromagnetic Relay
DELIXI CDZ9 Series Small Electromagnetic Relay
Back to products
DELIXI RT16A Fuse
DELIXI RT16A Fuse

Single Phase LCD RS485 KWH Power Meter 32A/40A

Dimensions:1 module
Accuracy Class:1
Brand Name:NewTrend or OEM
Application:Industrial,Household,electric power
Feature:LED Display,Durable,Light Weight,Safety,Sustainable
Place of Origin:China
Operating Temperature:-20…55 °C
Model Number:D1101, D1103
Display Type:Analog and Digital
Measuring Energy Range:5(32)A
Phase:Single Phase
SKU: 1770411956570693632 Category: Din Rail Energy Meter
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

32A 40A Analogue Digital LCD RS485 multi Modular Single Phase DIN rail mounted KWH Kilowatt hour Electricity Energy Power Meter

 

Product Description

The meter is designed to measure Single phase Two wire AC Active Energy like residential, utility and industrial application. It is a long life meter with the advantage of high stability, high over load capability, low power loss and small volume.

 

Basic Function

– Mechanical step register 5+1 or LCD display 6+1
– Bi-directional total active energy measurement, reverse active energy measure in the total active energy
– For LCD display type meter, Energy data can store in memory chip more than 15 years after power off
– Pulse LED indicates working of meter, Passive pulse output with optical coupling isolation
– 35mm din rail installation

– The meter also display real Voltage, Current, Active power, Power factor, Frequency, Import active energy, Export active energy

– Reset energy function (the reset energy kWh display is dependent with total energy display, this reset will not affect total energy )

– RS485 communication port, MODBUS-RTU protocol

 

Technique Parameters

 

Model D1101-1 D1101-2 D1103
Photo      
display type Electromechanical 5+1 LCD display 5+2 or 6+1
type of measurement Total Active Energy
Reverse Active Energy
Total Active Energy
Reverse Active Energy
Voltage
Current
Frequency
Power Factor
communication port protocol – Modbus RTU
communication port support – RS485 communication
energy reset function – energy resettable
poles description 1P + N
accuracy class Class 1, Active Energy conforming to IEC 62053-21
Input type Direct input
rated current 5(32)A or 5(40)A
rated voltage 230V ±20%
network frequency 50 Hz or 60Hz
impulse Constant 2000imp/kWh  
digital outputs 1 pulse 80±5ms, with optional coupling isolation
open collector output (SO) 18-27V 27 mA
start current <0.004Ib
maximum power consumption in VA <10 VA
mounting support 35mm DIN rail
standards IEC 62053-21, IEC 61557-12
operation temperature -20…70 °C < 32A, -20…55 °C >= 32A
wiring connection    
outline dimension    
Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Single Phase LCD RS485 KWH Power Meter 32A/40A.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Voltage & Load Sizing

How to verify rated operational voltage, frequency, and load duty cycle?

A

Verify that the nominal line voltage (AC 230V single-phase or 400V/415V/690V three-phase at 50/60Hz, or DC voltage ratings) falls within the continuous maximum operating limits of the device. Check duty cycle ratings (continuous vs intermittent duty) to ensure thermal stability under full load.

Protection & Environment

What ingress protection (IP Rating) and environmental enclosures are recommended?

A

For clean indoor electrical rooms, standard IP20 modular DIN-rail housings are recommended. For outdoor, industrial washdown, or dusty environments, mount components inside weatherproof enclosures rated IP65/IP66 with UV-resistant polycarbonate or powder-coated steel enclosures equipped with compression cable glands.

Selectivity & Grading

How to ensure upstream and downstream coordination in power distribution boards?

A

Ensure proper discrimination by grading current thresholds and tripping time delays: upstream devices should have higher current ratings and intentional short-time delays (Class S), allowing downstream branch MCBs to clear localized faults without blacking out the entire facility.

Installation & Mounting

What mounting rails, busbars, and spatial clearances are required?

A

Components mount on standard symmetrical 35mm DIN rail (EN 60715 / TH35-7.5) or backplate screw fixings. Maintain recommended top/bottom ventilation gaps (typically 30–50mm) to ensure unrestricted air convection, and use standard pin/fork comb busbars to minimize contact resistance and wiring errors.

Conductor & Torque Sizing

What conductor sizes and terminal tightening torques should be applied?

A

Select copper or aluminum conductor cross-sections complying with IEC 60364-5-52 current-carrying capacity tables based on continuous load. Always use a calibrated torque screwdriver or torque wrench to tighten terminal screws to the manufacturer-specified torque to prevent hot-spot degradation and loose connections.

Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...