Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
  • Home
  • Products
    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Automation & Control

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Circuit Breaker & Fuses

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Din-Rail Mounted Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Distribution Box & Cabinet

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Load Center & Meter Bases

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Solar PV Products

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Electrical Accessories

    CHINT NH40-250 3P 250A Auto Changeover Switch ATS

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Search
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Click to enlarge
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
Home Chint Electrical Materials Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter
DELIXI ACL, OCL Series Input and Output Reactor
DELIXI ACL, OCL Series Input and Output Reactor
Back to products
CHINT 0.16mm PVC Flame Retardant Insulation Tape 600V
CHINT 0.16mm PVC Flame Retardant Insulation Tape 600V

Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter

Motor Soft Starter; GB/T 14048.6, IEC 60947-4-2; for motor starting for pumps, fans and industrial machinery

Model
Rated control coil voltage options
Rated current range
SKU: NJRP5-D Category: Chint Electrical Materials
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description
Chint NJRP5-D Motor Soft Starter

Product Overview

For NJRP5-D, the official catalogue lists rated current range as 15A~1000A. For NJRP5-D, the official catalogue lists main loop voltage (d4) as AC200V~AC415V. For NJRP5-D, the official catalogue lists main loop voltage (d6) as AC200V~AC690V. For NJRP5-D, the official catalogue lists rated voltage ue (d4) as AC200~415V (-10%~+10%).

Technical Parameters

Rated control coil voltage options 220V, 380V, 460V, 575V, 690V
Rated current range 15A~1000A
Model NJRP5-D

Key Selling Points

✓ Product type: Soft starter
✓ Standard: GB/T 14048.6, IEC 60947-4-2
✓ Rated current range: 15A~1000A
✓ Main loop voltage (D4): AC200V~AC415V

Technical Highlights

  • Product type: Soft starter
  • Standard: GB/T 14048.6, IEC 60947-4-2
  • Rated current range: 15A~1000A
  • Main loop voltage (D4): AC200V~AC415V

Reference Datasheet Pages

The following pages were selected from the model catalogue and are included for technical reference:

NJRP5-D Catalog and Technical Data

NJRP5-D technical catalog page 1

NJRP5-D technical catalog page 2

NJRP5-D technical catalog page 3

NJRP5-D technical catalog page 4

NJRP5-D technical catalog page 5

Additional information
Rated control coil voltage options

220V, 380V, 460V, 575V, 690V

Rated current range

15A~1000A

Model

NJRP5-D

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for Chint NJRP5-D 220V/380V/460V/575V 45kW 55kW 75kW 90kW 110kW 160kW 200kW 250kW three-phase AC motors CHNT Soft Starter.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

Chint NKG1 3A AC220V 50Hz 1NO 16-Group Time Control Switch Digital Timer Switch AC-15 240V CHNT Time Switch
Chint NKG1 3A AC220V 50Hz 1NO 16-Group Time Control Switch Digital Timer Switch AC-15 240V CHNT Time Switch

Chint NKG1 3A AC220V 50Hz 1NO 16-Group Time Control Switch Digital Timer Switch AC-15 240V CHNT Time Switch

Programmable Time Switch; IEC 60947-5-1; for timed making and breaking in automatic control circuits
Chint NB1-63-H2 10kA 1A-63A 1P-4P B C D Curve IEC/EN 60947-2 Thermo-Magnetic DIN Rail MCB CHNT Miniature Circuit Breaker
Chint NB1-63-H2 10kA 1A-63A 1P-4P B C D Curve IEC/EN 60947-2 Thermo-Magnetic DIN Rail MCB CHNT Miniature Circuit Breaker

Chint NB1-63-H2 10kA 1A-63A 1P-4P B C D Curve IEC/EN 60947-2 Thermo-Magnetic DIN Rail MCB CHNT Miniature Circuit Breaker

Miniature Circuit Breaker; IEC/EN 60947; for distribution board and final circuit protection
Sold out
Chint NM8N 16A to 1600A 1P 2P 3P 4P 690V AC MCCB CHNT Industrial Power Distribution Moulded Case Circuit Breaker
Chint NM8N 16A to 1600A 1P 2P 3P 4P 690V AC MCCB CHNT Industrial Power Distribution Moulded Case Circuit Breaker

Chint NM8N 16A to 1600A 1P 2P 3P 4P 690V AC MCCB CHNT Industrial Power Distribution Moulded Case Circuit Breaker

Moulded Case Circuit Breaker; IEC/EN 60947-2; for feeder and motor protection
Chint NDK Single Phase 25VA-5000VA 12V 24V 110V 230V 400V Step-Down Machine Tool Transformer CHNT NDK Control Transformer
Chint NDK Single Phase 25VA-5000VA 12V 24V 110V 230V 400V Step-Down Machine Tool Transformer CHNT NDK Control Transformer

Chint NDK Single Phase 25VA-5000VA 12V 24V 110V 230V 400V Step-Down Machine Tool Transformer CHNT NDK Control Transformer

Machine Tool Control Transformer; Q/ZT258; for machine tools and industrial control panels
Chint KG10M 3A AC220V 50Hz 16-Group Time Control Switch Digital Timer Switch AC 220V CHNT Time Switch
Chint KG10M 3A AC220V 50Hz 16-Group Time Control Switch Digital Timer Switch AC 220V CHNT Time Switch

Chint KG10M 3A AC220V 50Hz 16-Group Time Control Switch Digital Timer Switch AC 220V CHNT Time Switch

Panel type time switch compliant with IEC 60947-5-1, featuring 1 normally-open contact and built-in rechargeable battery.
Chint NJYB2 0.47A 380V/400V/415V 50Hz Industrial Control Relay Protection Relay CHNT Voltage Protection Relay
Chint NJYB2 0.47A 380V/400V/415V 50Hz Industrial Control Relay Protection Relay CHNT Voltage Protection Relay

Chint NJYB2 0.47A 380V/400V/415V 50Hz Industrial Control Relay Protection Relay CHNT Voltage Protection Relay

Three-phase three-wire rail mounting relay providing phase loss, phase sequence, overvoltage and undervoltage protection
Chint NVF3M 220V 380V IP20 Vector Control 150% Overload VFD AC Motor Drive CHNT Variable Frequency Inverter
Chint NVF3M 220V 380V IP20 Vector Control 150% Overload VFD AC Motor Drive CHNT Variable Frequency Inverter

Chint NVF3M 220V 380V IP20 Vector Control 150% Overload VFD AC Motor Drive CHNT Variable Frequency Inverter

Variable Frequency Drive; GB/T 12668.2-2002, IEC 61800-2; for motor speed control for pumps, fans and industrial machinery
Chint JKF8 Auto-Polarity PF Controller 380V 6/12 Loops CHNT Intelligent Low-Voltage Reactive Power Compensation Controller
Chint JKF8 Auto-Polarity PF Controller 380V 6/12 Loops CHNT Intelligent Low-Voltage Reactive Power Compensation Controller

Chint JKF8 Auto-Polarity PF Controller 380V 6/12 Loops CHNT Intelligent Low-Voltage Reactive Power Compensation Controller

Features 50/60Hz operation, 150mA to 5A sampling current, real-time parameter display, and 113mm x 113mm boring mounting.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • Chint NJJ7 0.75A DC100V/240V/DC24V 50Hz Industrial Control Relay Protection Relay CHNT Counting relay Chint NJJ7 0.75A DC100V/240V/DC24V 50Hz Industrial Control Relay Protection Relay CHNT Counting relay
  • CHINT NZK2-32 Isolating Switch CHINT NZK2-32 Isolating Switch
  • CHINT SHT-X1 Shunt Release for NXB-63 / NXB-40 MCB Accessories CHINT SHT-X1 Shunt Release for NXB-63 / NXB-40 MCB Accessories
  • Chint NB1-63-H2 10kA 1A-63A 1P-4P B C D Curve IEC/EN 60947-2 Thermo-Magnetic DIN Rail MCB CHNT Miniature Circuit Breaker Chint NB1-63-H2 10kA 1A-63A 1P-4P B C D Curve IEC/EN 60947-2 Thermo-Magnetic DIN Rail MCB CHNT Miniature Circuit Breaker
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...