LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
  • Home
  • Products
    QOD2F 2 Space Flush Load Center

    Automation & Control

    QOD2F 2 Space Flush Load Center

    Circuit Breaker & Fuses

    QOD2F 2 Space Flush Load Center

    Din-Rail Mounted Products

    QOD2F 2 Space Flush Load Center

    Distribution Box & Cabinet

    QOD2F 2 Space Flush Load Center

    Load Center & Meter Bases

    QOD2F 2 Space Flush Load Center

    Solar PV Products

    QOD2F 2 Space Flush Load Center

    Electrical Accessories

    QOD2F 2 Space Flush Load Center

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
Search
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
Click to enlarge
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
Home Electrical Accessories Others LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch
LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
Back to products
22mm Digital LED Panel Meter (Ammeter/Voltmeter/Indicator)
22mm Digital LED Panel Meter (Ammeter/Voltmeter/Indicator)

LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch

Whether the smart:NO
Brand Name:Newtrend or OEM brand
Place of Origin:China
Max. Current:20A
Mechanical Life:1000000
Model Number:LW26 4.I7168/7
Max. Voltage:690V
Certification:CE
SKU: 1770408261170765824 Category: Others
  • Description
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

LW26 4.I7168/7 20A 7 LEVELS 8 POSITIONS Rotary Cam Switch

 

Rotary switches LW26 series

The rotary switches LW26 series are produced for switching on/off electrical circuits with commutated current from
20 to 160A. They are designed on the bases of the rotor-eccentric switching on which is realized through turning
of the handle to 60 or 90 degrees. The normal operation is used for commutation of two, three or four conductor
systems. There are special rotary switches that switch on under given connection schemes and are used to
control motors, electric welding machines and other consumers.

Documentation corresponding to the product:
Standard: EN 60947-1; EN 60947-3-1

Technical data:
* Power supply voltage: 230/400V; 50Hz
* Insulation voltage: 690V
* Impulse voltage wear resistance: 6000V
* Mechanical wear resistance: 3×105 commutation cycles
* Operation temperature: -10 ~ +50 ℃
* Humidity: 35 – 85% RH
* Commuting capacity: up to 160A according to the tables
* Plastic: UV rays wear resistance
* IP code:
– IP42 for the ordinary breakers mounted in a panel
– IP65 for the breakers offered in a box
* Cable connection: screw joining
* Tightening moment of the bolt: 1.33N
* Maximum section of the power supply conductors: according to the dimensions table
* Weight: according to the number of the contacts
Mounting:
* directly to the control panel
* thickness of the surface to which it is mounted: max 5mm

 

Model

Characteristics

Current Available

Positions

LW26 -** 0-1-2-3

Acts with selectivity up to 3 different circuits, single-phase operation

20/25/32/63

4 (0-1-2-3)

LW26 -** 0-1-2-3-4

Acts with selectivity in up to 4 different circuits, single-phase operation

20/25/32/63

5 (0-1-2-3-4)

LW26 -** 0-Y-D

Used for 3 position switching, O-star-delta, motor starter switch

25/32/63

3 (0-Y-D)

LW26 -** 6S/4

Used for two speed motor control; switching over between charging

25/32/63

3 (1-0-2)

LW26 -** YH3/3

Used for line meters in three-phase systems

20

4 (0-RS-ST-TR)

LW26 -** YH5/3

Used for voltage switching over

20

7 (TR-ST-RS-0-

RN-SN-TN)

LW26 -** LH3/3

Used for amperemeter switching on to current transformers

20

4 (0-R-S-T)

LW26 -** 6N/3

Used for phase inversion / rotation in three-phase system

20/32/63/125/160

3 (1-0-2)

LW26 -** 6Q/2

Used for three-poles switching on; motor starting and stopping; voltage on/off

20/32/63/125/160

2 (0-1)

LW26 -** D0081/1

Transfer switch (switching) monopolar

125/160

3 (1-0-2)

LW26 -** D0723/3

Transfer switch (switching) tripolar

125/160

3 (1-0-2)

LW26 -** D1050/4

Transfer switch (switching) tetrapolar

125/160

3 (1-0-2)

 

Description

LW26-20

LW26-25

LW26-32

LW26-63

LW26-125

LW26-160

Thermal Current (Ith)

20 A

25 A

32 A

63 A

125 A

160 A

Working Voltage (Ue)

240V

440V

240V

440V

240V

440V

240V

440V

240V

440V

240V

440V

Working Current (Ie)

A

AC21/AC22

20

25

32

63

100

150

AC23

15

22

30

57

90

135

AC2

15

22

30

57

90

135

AC3

11

15

22

36

75

95

AC4

3,5

6,5

11

15

30

55

AC15

5

4

8

5

14

6

***

***

***

Power

kW

AC23

3,7/2,5

7,5/3,7

5,5/3

11/5,5

7,5/4

15/7,5

15/10

30/18,5

30/15

45/22

37/22

75/37

AC2

4

7,5

5,5

11

7,5

15

18,5

30

30

45

37

55

AC3

3/2,2

5,5/3

4/3

7,5/3,7

5,5/4

11/5,5

11/6

18,5/11

15/7,5

30/13

22/11

37/18,5

AC4

0,55/0,75

1,5/1,5

1,5/1,1

3/2,2

2,7/1,5

5,5/3

5,5/2,4

7,5/4

6/3

12/5,5

10/4

15/7,5

 

 

Model

Front Plate

A

B

C

E

F

L

D1

D2

LW26-20

Square

48

48

43

36

36

22+9.6n

Φ8.5

Φ4.5

LW26-20*

Retangular

48

60

43

36

36

22+9.6n

Φ8.5

Φ4.5

LW26-25

Square

48

48

45

36

36

23+12.8n

Φ8.5

Φ4.5

LW26-32

Square

64

64

58

48

48

29.2+12.8n

Φ10

Φ4.5

LW26-63

Square

64

64

66

48

48

29.2+21.5n

Φ10

Φ4.5

LW26-125

Square

88

88

84

68

68

35+26.5n

Φ13

Φ6

LW26-160

Square

88

88

88

68

68

35+32.5n

Φ13

Φ6

* n = number of modules

 

 

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for LW26 4.I7168/7 20A 7-Level 8-Position Rotary Cam Switch.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Voltage & Load Sizing

How to verify rated operational voltage, frequency, and load duty cycle?

A

Verify that the nominal line voltage (AC 230V single-phase or 400V/415V/690V three-phase at 50/60Hz, or DC voltage ratings) falls within the continuous maximum operating limits of the device. Check duty cycle ratings (continuous vs intermittent duty) to ensure thermal stability under full load.

Protection & Environment

What ingress protection (IP Rating) and environmental enclosures are recommended?

A

For clean indoor electrical rooms, standard IP20 modular DIN-rail housings are recommended. For outdoor, industrial washdown, or dusty environments, mount components inside weatherproof enclosures rated IP65/IP66 with UV-resistant polycarbonate or powder-coated steel enclosures equipped with compression cable glands.

Selectivity & Grading

How to ensure upstream and downstream coordination in power distribution boards?

A

Ensure proper discrimination by grading current thresholds and tripping time delays: upstream devices should have higher current ratings and intentional short-time delays (Class S), allowing downstream branch MCBs to clear localized faults without blacking out the entire facility.

Installation & Mounting

What mounting rails, busbars, and spatial clearances are required?

A

Components mount on standard symmetrical 35mm DIN rail (EN 60715 / TH35-7.5) or backplate screw fixings. Maintain recommended top/bottom ventilation gaps (typically 30–50mm) to ensure unrestricted air convection, and use standard pin/fork comb busbars to minimize contact resistance and wiring errors.

Conductor & Torque Sizing

What conductor sizes and terminal tightening torques should be applied?

A

Select copper or aluminum conductor cross-sections complying with IEC 60364-5-52 current-carrying capacity tables based on continuous load. Always use a calibrated torque screwdriver or torque wrench to tighten terminal screws to the manufacturer-specified torque to prevent hot-spot degradation and loose connections.

Related products

LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor
LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:9A
Sold out
LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

LC1D258 LC1DT40 4P 40A AC Contactor 24V-380V Coil Options

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D258
Phase:3
Main Circuit Rating Current:25A
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC66P
Phase:1
Main Circuit Rating Current:200A
Sold out
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V
iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

iCT 16A-100A 1P-4P DIN Rail Modular Contactor 24V/220V

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:GC, iCT
Phase:1
Main Circuit Rating Current:12A ~ 100A
Sold out
2P/4P Type AC/A Auto Reset RCCB RCBO Differential Switch 25A-63A
2P/4P Type AC/A Auto Reset RCCB RCBO Differential Switch 25A-63A

2P/4P Type AC/A Auto Reset RCCB RCBO Differential Switch 25A-63A

BCD Curve:C
Type:RCCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:RD9L-R + YL9
Rated Frequency (Hz):50/60Hz
Protection:LSIG
Breaking Capacity:6kA
Rated Voltage:230/400V
750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor
LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

LP1K 3P/4P 6A-16A 12VDC/24VDC TeSys K Mini DC Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LC1K LP1K
Phase:3
Main Circuit Rating Current:6A 9A 12A 16A
type:Magnetic contactor
NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor
NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor

NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K09, LP1K12
Phase:3
Main Circuit Rating Current:9A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch LW26 25A-63A 3-Position Star-Delta Motor Starter Rotary Switch
  • DELIXI CDM3LT Transparent Residual Current MCCB DELIXI CDM3LT Transparent Residual Current MCCB
  • DELIXI CDI-EM60 Series Mini Type VFD DELIXI CDI-EM60 Series Mini Type VFD
  • Wirtgen 2073392 AB 600-2 TP2 Asphalt Paver Screed Repair Kit Wirtgen 2073392 AB 600-2 TP2 Asphalt Paver Screed Repair Kit
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the star.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...