NewTrend · W400A / SW200
Product overview
NewTrend W400A normally-open DC contactor with a confirmed 400A continuous carrying rating. Select the DC coil voltage independently of the main circuit.
Technical selection summary
| Parameter | Specification |
|---|---|
| Identity | NewTrend W400A; SW200 is a reference designation, not original Albright supply |
| Main circuit | Single normally-open pole; 400A continuous duty confirmed for actual supply |
| Coil supply | DC12/24/36/48/72V confirmed; separate from main-contact voltage |
| Source reference | 11-14W coil; pickup/dropout <30ms; pickup <66%Us; dropout 5-30%Us |
| Insulation | 1000VAC 50Hz for 1 minute reference |
| Endurance reference | Mechanical 100000 / electrical 20000 operations |
| Drawings | Original contact circuit and both mechanical outlines retained |
Actual 400A continuous supply and W-model naming follow owner confirmation. The old 200A text is superseded; a carrying rating does not establish an interrupting capacity for every DC load.
Typical applications
- DC load and motor switching within the confirmed load duty
Open technical reference image
Main circuit voltage: Max 80V DC for the supplied NewTrend version. Coil voltage is selected separately. Any 48V contact-circuit marking in retained legacy reference drawings describes the earlier reference, not the current supplied rating.