2 Pole 1000V DC MCB 2 Pole 1000V DC MCB
  • Home
  • Products
    QOD2F 2 Space Flush Load Center

    Automation & Control

    QOD2F 2 Space Flush Load Center

    Circuit Breaker & Fuses

    QOD2F 2 Space Flush Load Center

    Din-Rail Mounted Products

    QOD2F 2 Space Flush Load Center

    Distribution Box & Cabinet

    QOD2F 2 Space Flush Load Center

    Load Center & Meter Bases

    QOD2F 2 Space Flush Load Center

    Solar PV Products

    QOD2F 2 Space Flush Load Center

    Electrical Accessories

    QOD2F 2 Space Flush Load Center

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
2 Pole 1000V DC MCB 2 Pole 1000V DC MCB
Search
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
Click to enlarge
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
2 Pole 1000V DC MCB
Home Solar PV Products DC MCB 2 Pole 1000V DC MCB
Chint NX2 Distribution Box
Chint NX2 Distribution Box
Back to products
LP1K DC Control Mini Contactor (6A-12A)
LP1K DC Control Mini Contactor (6A-12A)

2 Pole 1000V DC MCB

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DB1-63Z
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:1000V
Poles
Rated Current
SKU: 1600568767632 Category: DC MCB
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

2P DC 1000V Solar Mini Circuit Breaker 1A 2A 3A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A 2 pole DC MCB for PV System

 

Product
NB1-63Z DC Mini Circuit Breaker
Frame degree rated current
63A
Pole
2P
Rated Operating Voltage
1000V DC
Rated Current In
1A, 2A, 3A, 4A, 6A, 10A, 16A, 
20A, 25A, 32A, 40A, 50A, 63A
Rated Insulation Voltage Ui
1200V DC
Rated Impact Voltage Uimp
4KV
Ultimate Breaking Capacity lcu
6KA
Run Breaking Capacity lcs
75%
Curve Type
C
Trip Type
Thermal-magnetic
Mechanical Life
20000 times
 
Electrical Life
2500 times
 

 

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Rated Current

1A – 63A

Poles

2P

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for 2 Pole 1000V DC MCB.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

Curve Selection

How to choose between Tripping Curves B, C, and D for this miniature circuit breaker?

A

Curve B trips at 3–5 In (designed for resistive loads, electric heating, and domestic appliances with negligible inrush). Curve C trips at 5–10 In (the standard international choice for residential and commercial lighting, socket outlets, and small induction motors). Curve D trips at 10–14 In (specifically engineered for high-inrush inductive equipment such as industrial transformers, heavy motors, compressors, and welding circuits).

Breaking Capacity

How do I determine whether 6kA or 10kA breaking capacity is required for my installation?

A

Breaking capacity (Icn/Icu) must exceed the calculated prospective short-circuit fault current at the installation point. 6kA (IEC 60898-1) is standard for residential consumer units and sub-distribution branch circuits located downstream. 10kA (IEC 60947-2) is required for industrial facilities, main switchboards, commercial distribution panels, or circuits situated close to supply transformers where fault levels are high.

Poles & Neutral Isolation

How to choose the correct number of poles (1P, 1P+N, 2P, 3P, 3P+N, 4P) for single-phase and three-phase circuits?

A

For single-phase 230V circuits: 1P provides active phase protection; 1P+N or 2P isolates both live and neutral lines simultaneously (essential for TT earthing systems and sensitive sub-panels). For three-phase 400V systems: 3P protects balanced 3-wire motor loads; 3P+N or 4P is required for 4-wire mixed single-phase loads to ensure complete neutral disconnection during isolation.

DC vs AC Application

Can this circuit breaker be used in DC circuits (Solar PV, Battery Storage, Telecom)?

A

Standard AC breakers cannot safely extinguish DC arcs due to the absence of natural zero-crossing current. For DC circuits (60V to 1000V DC), select specialized DC breakers (such as DZ158-125 DC or NM8NDC series) equipped with permanent magnetic arc-blowout chutes and strictly observe polarity wiring to prevent arc re-ignition.

Modular Accessories & Interlocks

What modular accessories and mechanical interlocks can be fitted to this breaker?

A

Standard modular clip-on accessories can be mounted directly on the side without tools: OF (Auxiliary Contact for remote status indication), SD (Alarm Contact for trip fault signaling), MX (Shunt Trip for remote emergency tripping), MN (Under-voltage Release for voltage loss protection), and NXBZ mechanical interlock kits for manual generator/mains transfer switches.

Related products

DZ47-125z DC MCB 125A 100A 80A
DZ47-125z DC MCB 125A 100A 80A

DZ47-125z DC MCB 125A 100A 80A

Brand Name:Newtrend or OEM
Place of Origin:China
Province:Zhejiang
Model Number:DZ47-125Z
Type:Mini
DZ47-63z DC MCB
DZ47-63z DC MCB

DZ47-63z DC MCB

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DZ47-63Z
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:220V,400V ,230V,240V,380V
PV DC Breaker 2P 1000V 32A Solar Miniature Circuit Breaker

PV DC Breaker 2P 1000V 32A Solar Miniature Circuit Breaker

2-pole 1000V 32A PV DC breaker for solar combiner boxes, photovoltaic arrays, and battery-side DC protection. DIN rail mounting, compact design, and practical export supply for solar projects and wholesale buyers.

PV DC Breaker 2P 500V 32A Solar Miniature Circuit Breaker
PV DC Breaker 2P 500V 32A Solar Miniature Circuit Breaker

PV DC Breaker 2P 500V 32A Solar Miniature Circuit Breaker

2-pole 500V 32A PV DC breaker for solar combiner boxes, battery DC distribution, and photovoltaic protection systems. DIN rail mounting, IEC 60898-2 standard, compact structure, and practical export supply for project and wholesale buyers.
Sold out
CHINT NB1-63DC DC Miniature Breaker 500V/1000V 10A-63A
CHINT NB1-63DC DC Miniature Breaker 500V/1000V 10A-63A

CHINT NB1-63DC DC Miniature Breaker 500V/1000V 10A-63A

CHINT NB1-63DC DC miniature breaker for 500VDC / 1000VDC applications, available from 10A to 63A. Suitable for photovoltaic DC protection, communication systems, and compact low-voltage direct current circuits.
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • CHINT NB1-63DC DC Miniature Breaker 500V/1000V 10A-63A CHINT NB1-63DC DC Miniature Breaker 500V/1000V 10A-63A
  • PV DC Breaker 2P 1000V 32A Solar Miniature Circuit Breaker PV DC Breaker 2P 1000V 32A Solar Miniature Circuit Breaker
  • PV DC Breaker 2P 500V 32A Solar Miniature Circuit Breaker PV DC Breaker 2P 500V 32A Solar Miniature Circuit Breaker
  • DZ47-125z DC MCB 125A 100A 80A DZ47-125z DC MCB 125A 100A 80A
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the star.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...