Showing 853–864 of 1333 results

ABB XT3N 250 TMD 250-2500 3P MCCB, 1SDA068059R1

XT3N 250 TMD 250-2500 3p F F is the default configuration on this page, with ABB ordering reference 1SDA068059R1. Thermal overload and fixed instantaneous short-circuit protection. The base device matches the title. Select compatible mounting parts and electrical accessories; the selected model and ordering references are recorded in your quote list.

NOARK ASD25 UL DC Disconnect Switch, 1500Vdc, 800–2500A

Original NOARK ASD25 UL DC disconnect switches for 1500Vdc photovoltaic and energy-storage equipment. Select current, documented withstand class, rear-terminal orientation and C/D wiring.

People Electric RDU8DC DC Surge Protective Device, 1000V, 20/40kA

Original People Electric RDU8DC DC surge protective device. Select B20 (Imax 20kA) or B40 (Imax 40kA), and 2P or 3P. This page covers the DC1000V maximum continuous operating-voltage ratings.

People Electric RDM8DC DC Moulded Case Circuit Breaker, 63–800A

Original People Electric RDM8DC thermal-magnetic DC MCCB. Select the documented frame/poles/voltage combination and its rated current; DC wiring must follow the manufacturer diagram.

People Electric SFSZ11-240000/220 Three-Winding OLTC Transformer, 240MVA

Original People Electric SFSZ11-240000/220 three-phase, three-winding OLTC power transformer. Catalogue winding capacities240/240/120MVA and230/121/38.5kV voltage combination; confirm the complete project design and guarantees.

NOARK Ex9RD UL Thermal Overload Relay, 0.1–630A

Original NOARK Ex9RD UL-listed thermal overload relays for coordinated motor-starter assemblies. Select the exact relay frame and adjustable current-setting range.

People Electric XJ01E Motor Soft Starter Cabinet, 14–500kW

Original People Electric XJ01E thyristor soft starter cabinet for three-phase AC induction motors. Select a documented 14–500kW rating; supply AC400V ±10%, 50Hz. Confirm load duty, motor current and the supplied cabinet configuration.

People Electric RDB67LE-63 RCBO, C63 3P 30mA 4.5kA

Original People Electric RDB67LE-63 RCBO in the pictured C63 version: 3P, AC400V, 30mA and 4.5kA. Original manufacturer branding and photographs retained.

ABB AF09-30-01-13 3P Contactor, 9A AC-3, 1SBL137001R1301

AF09-30-01-13, ABB 1SBL137001R1301: 9A AC-3 at 400V, AC/DC 100-250V coil, 3NO main contacts and 1NC supplied auxiliary contacts. The base parameters match this title; compatible additional auxiliary blocks and their order codes are included in your quote list.

People Electric HZ10 Rotary Combination Switch, 10/25/63A

Original People Electric HZ10 rotary combination switch for infrequent manual circuit switching. Choose 10/25/63A conventional thermal current and a supported pole count: 1P only at 10A; 2P/3P at 10/25/63A.

People Electric RDM108 Motor Protection Circuit Breaker, Adjustable 0.4–63A

Original People Electric RDM108 three-pole motor-protection breaker. Select the documented frame/voltage and current-setting range. Main ratings are confirmed against the manufacturer Chinese industrial-control handbook.

ABB XT5N 400 Ekip Dip LS/I In=400 3P MCCB, 1SDA100354R1

XT5N 400 Ekip Dip LS/I In=400 3p F F is the default configuration on this page, with ABB ordering reference 1SDA100354R1. Electronic protection with the Ekip Dip LS/I trip unit; use its documented protection functions and settings. The base device matches the title. Select compatible mounting parts and electrical accessories; the selected model and ordering references are recorded in your quote list.