AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor
  • Home
  • Products
    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Automation & Control

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Circuit Breaker & Fuses

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Din-Rail Mounted Products

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Distribution Box & Cabinet

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Load Center & Meter Bases

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Solar PV Products

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Electrical Accessories

    CHINT ZTY0204B ZTW890C/D/S AC DC NCV Digital Clamp Multimeter

    Chint Electrical Materials

  • About
  • Blog
  • Cross-Reference
  • Contact
Search

Email: sales@sntelec.com
0086-18019187010 (WhatsApp)

Menu
AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor
Search
AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor
Click to enlarge
Home Electrical Accessories Others AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor
NewTrend 200A Magnetic Latch DC Contactor w/ Auxiliary Contact
NewTrend 200A Magnetic Latch DC Contactor w/ Auxiliary Contact
Back to products
SW60 80A 48V/96V Albright Equivalent DC Solenoid for EVs
SW60 80A 48V/96V Albright Equivalent DC Solenoid for EVs

AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:JW250C
Phase:1
Main Circuit Rating Current:100A 200A 250A 400A
Electric Life:20000 Times
Dielectric Strength:50HZ 1000V AC 1Min
Rated Voltage Of Contact Circuit:DC 6V-80V
Main Rated Load Current:100A 200A 250A 400A
Coil Power:14W-17W
OEM:Avaliable
Number of Pole
Main Circuit Rating Voltage
SKU: 1600719933541 Category: Others
  • Description
  • Additional information
  • Technical Datasheet & Downloads
  • Technical FAQ & Selection Guide
Description

China good quality DC Contactor equivalent AMETEK JAY46 JBY46 JFY48 JHY48 Magnetic Latching Contactor

 

JW series 100A, 200A, 250A, 400A Magnetic Latching DC Contactor are suitable for air conditioner, the battery or the rectification power and suppliers power,using for handling drawing,the pump motor and other electronic vehicle. 

Type Magnetic Latching DC Contactor
Model JW100C JW200C JW250C JW400C
Main Rated Load Current Of Contact Circuit 100A 200A 250A 400A
Rated Voltage Of Contact 6-80V DC
Rated Voltage Of Coil 12V, 24V, 48V, 72V, 110V, 220VDC
Coil Power 14-17W
Dielectric(Volt) Strength 50HZ 1000V AC 1Min
Rated Load Current Of Contact Circuit Not Above 80mv
Operating Time Pickup(Contact makes): less than 30 ms
Release(Contact breaks):  less than 30 ms
Action Characteristic Pickup(Contact makes): less than 66%us
Release(Contact breaks): less than 30%us, more than 5%us
Mechanical Life 100 Thouand times
Electric Life 20 Thousand Times

 

 

JW100C 100A Magnetic Latching DC Contactor Dimension:

 

 

JW200C 200A Magnetic Latching DC Contactor Dimension:

 

 

JW250C 250A Magnetic Latching DC Contactor Dimension:

 

 

JW400C 400A Magnetic Latching DC Contactor Dimension:

Additional information
Weight 2 kg
Dimensions 25 × 25 × 25 cm
Number of Pole

1

Main Circuit Rating Voltage

Other

Technical Datasheet & Downloads

📄 Technical Documentation & Product Specifications

Download official engineering datasheets, certified test standards (IEC / UL / CE), wiring diagrams, and dimensional drawings for AMETEK JAY46/JBY46/JFY48/JHY48 Equivalent Magnetic Latching Contactor.

📥
Official Technical Datasheet (PDF) Complete electrical ratings, tripping characteristics, dimensions, and compliance specifications.
Request Official Datasheet (PDF)
📐
2D/3D CAD & Dimensional Drawings STEP, DXF, and PDF CAD drawing files for panel builders and switchgear designers.
Request CAD Model
Certified Standards: IEC 60898-1, IEC 60947-2, CE, RoHS, ISO 9001:2015
Manufacturer: Shanghai Newtrend Electric Co., Ltd. (Global Export Compliance)
Engineering Support: 24-hour response for custom voltage ratings, auxiliary contacts, and technical consulting.
Technical FAQ & Selection Guide

💡 Frequently Asked Technical Questions & Selection Guide

Pure engineering specifications, tripping curve parameters, and electrical selection guidance for panel builders and system designers.

AC-1 / AC-3 Duty

How to calculate contactor rating based on motor power and utilization categories (AC-1 vs AC-3 vs AC-4)?

A

AC-3 rating applies to standard squirrel-cage motor starting and stopping during normal run (starting current 5–7x In). For non-inductive or purely resistive heating loads, use the higher AC-1 rating. For severe inching, jogging, and plugging applications (AC-4 duty), derate the contactor or upsize by 1 to 2 frame sizes to prevent contact erosion.

Coil Voltage Selection

How to choose the correct control coil voltage, frequency, and electronic wide-voltage options?

A

Standard AC coils include 24V, 48V, 110V, 220V/230V, 380V at 50/60Hz. For DC control loops or PLC outputs, specify DC coils or electronic wide-range AC/DC coils (e.g. 100V–250V AC/DC) which feature built-in surge suppression, low holding power consumption, and immunity to voltage dips.

Overload Coordination

How to size and coordinate the matching thermal overload relay (TOR) for Type 2 protection?

A

Select a thermal overload relay whose current setting range straddles the motor full-load current (FLA). Set the dial precisely to 1.0x motor nameplate FLA. For IEC 60947-4-1 Type 2 coordination, pair the contactor and relay with backed-up upstream fuses or fast-acting MCB/MCCB to prevent welding under fault conditions.

Auxiliary & Interlocks

What auxiliary contact blocks and mechanical interlocks can be added for motor reversing?

A

Units feature built-in 1NO or 1NC auxiliary contacts, expandable with top-mounted 2-pole or 4-pole auxiliary contact blocks (F4 / AX) and pneumatic timer delay blocks. For forward/reverse motor starters or star-delta starter assemblies, add side-mounted mechanical interlock units (MI) with electrical interlocking.

Ambient & Altitude Derating

How do ambient temperature and installation altitude affect contactor performance?

A

Standard ratings are calibrated for -5°C to +40°C. For ambient temperatures exceeding 55°C or altitudes above 2000m (where reduced air density diminishes heat dissipation and dielectric insulation), derate operational current by 2% per 100m above 2000m and verify insulation voltage limits per IEC standards.

Related products

THQL2150 2-Pole 50A 120V/240V 10kA Q-Line Circuit Breaker
THQL2150 2-Pole 50A 120V/240V 10kA Q-Line Circuit Breaker

THQL2150 2-Pole 50A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:100V,220V,230V,240V
750V-1000V High Voltage Automotive EV Contactor 50A-400A
750V-1000V High Voltage Automotive EV Contactor 50A-400A

750V-1000V High Voltage Automotive EV Contactor 50A-400A

Electricity Type:DC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:G50HS, G100HS, G150HS, G250HS, G300HS
Phase:1
Main Circuit Rating Current:50A 100A 200A 250A 300A 400A 500A
Contact Voltage Rating:12 - 1000V DC
Contact Form:SPST-NO
Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Albright Equivalent DC88-P Series 24VDC 100A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC88P
Phase:1
Main Circuit Rating Current:500A
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor
Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Albright Equivalent DC66-3P/10P/14P 24VDC 50A Reversing Contactor

Electricity Type:DC
Brand Name:Newtrend or OEM
Place of Origin:China
Model Number:DC66P
Phase:1
Main Circuit Rating Current:200A
DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A
DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A

DELIXI CDB6i 1P-4P MCB Air Switch Circuit Breaker 6A-25A

BCD Curve:C
Type:MCB
Brand Name:Delixi
Place of Origin:China
Model Number:CDB6i
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:6kA
Rated Voltage:220V,400V ,230V,240V,380V
THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker
THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker

THQL2170 2-Pole 70A 120V/240V 10kA Q-Line Circuit Breaker

BCD Curve:C
Type:MCB
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:THQL
Rated Frequency (Hz):50/60hz
Protection:LSI
Breaking Capacity:10kA
Rated Voltage:100V,220V,230V,240V
NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor
NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor

NewTrend LP1K0910KD/0901KD 3P 9A 100VDC Solder Pin Mini Contactor

Electricity Type:AC
Brand Name:NewTrend or OEM
Place of Origin:China
Model Number:LP1K09, LP1K12
Phase:3
Main Circuit Rating Current:9A
LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor
LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

LC1D09M7C TeSys 9A AC220V Electric Magnetic Contactor

Electricity Type:AC
Brand Name:Newtrend or OEM brand
Place of Origin:China
Model Number:LC1D
Phase:3
Main Circuit Rating Current:9A
Close
Product categories
  • Circuit Breaker & Fuses
    • Plug in Circuit Breaker
    • MCCB Circuit Breaker
    • ACB Circuit Breaker
    • Fusegear
    • Switch Disconnector
    • Manual Changeover Switch
    • Automatic Changeover Switch
    • Circuit Breaker Auxiliaries
    • UL Listed Plug in Breaker
    • UL Listed MCCB
    • UL Listed ACB
  • Automation & Control
    • AC Contactors
    • DC Contactors
    • Overload Relays
    • Motor Manual Starters
    • Frequency Inverters
    • Relays
    • Pushbuttons
    • Pilot Lights
    • Tower Lamps
  • Din-Rail Mounted Products
    • MCB
    • RCCB
    • RCBO
    • Auto Reclosing RCCB & RCBO
    • Modular Contactor
    • Surge Protector SPD
    • Over Under Voltage Protector
    • Din Rail ATS
    • Din Rail Changeover Switch
    • Din Rail Energy Meter
    • UL Listed MCB
  • Distribution Box & Cabinet
    • Distribution Box
    • Metal Enclosure
    • RA Junction Box (Economic)
    • GT Junction Box (Hinged)
    • NT Junction Box
    • KT Junction Box
    • Aluminum Junction Box
  • Load Center & Meter Bases
    • PowerMark Load Center
    • CH Load Center
    • QOD Load Center
    • QOL Load Center
    • TLS Load Center
    • Meter Bases
    • Steel Junction Box
    • UL Listed Load Center
  • Solar PV Products
    • DC MCB
    • DC MCCB
    • DC Fuses
    • DC SPD
    • DC Isolator Switch
    • PV Combiner Box
    • Solar PV Connector
    • Waterproof Box
  • Electrical Accessories
    • Terminal Blocks
    • Pre Insulated Terminals
    • Industrial Plug & Sockets
    • Insulator
    • Wiring Accessories
    • Din Rail
    • Meter & Transformer
    • Others
      • Delixi Electrical Materials
        • Delixi MCB
        • Delixi RCCB RCBO
        • Delixi MCCB ACB
        • Delixi Contactor & Overload Relays
        • Delixi Relays
        • Delixi Fuse & Disconnectors
        • Delixi Inverter & Soft Starters
        • Delixi Pushbutton & Pilot Lights
        • Delixi Changeover Switches
        • Delixi Capacitor & Reactors
        • Delixi Voltage Stabilizers
  • Chint Electrical Materials
    • Chint MCB
    • Chint RCCB RCBO
    • Chint MCCB ACB
    • Chint Contactor & Overload Relays
    • Chint Inverter & Soft Starters
    • Chint Relays
    • Chint Fuse & Disconnectors
    • Chint Pushbutton & Pilot Lights
    • Chint Changeover Switches
    • Chint Capacitor & Reactors
    • Chint Voltage Stabilizers
YOU MAY ALSO LIKE…
  • LC1-D AC/DC Coil Magnetic Contactor LC1D09 to LC1D95 LC1-D AC/DC Coil Magnetic Contactor LC1D09 to LC1D95
  • CHINT NJG2 1-Phase 3-Phase Solid State Relay 25A-100A CHINT NJG2 1-Phase 3-Phase Solid State Relay 25A-100A
  • DELIXI HR17 Series Fusible Disconnecting Switch DELIXI HR17 Series Fusible Disconnecting Switch
  • LR2D1310 3P 4A-6A Motor Thermal Overload Relay for LC1D LR2D1310 3P 4A-6A Motor Thermal Overload Relay for LC1D
  • Home
  • Products
  • Factory
  • About
  • Blog
  • Contact
Main Products
More+
  • Privacy Policy
  • Refund and Returns Policy
  • Shipping policy
  • Terms-of-service

CONTACT US

  • 0086-18019187010 (WhatsApp)
  • 0086-21-37699020
  • 0086-21-64059929
  • sales@sntelec.com
  • Room J7855, 108, 1st Floor, Building 1, No. 6988, Jiasong North Road, Anting Town, Jiading District, Shanghai, China
LEAVE A MESSAGE

Get a Free Quote


    Please prove you are human by selecting the tree.

    Copyright @ Shanghai Newtrend Electric Co., Ltd. All Rights Reserved
    • Menu
    • Categories
    • Home
    • Products
    • Factory
    • About
    • Blog
    • Contact
    • Home
    • Products
    • Cross-Reference
    • Case
    • Factory
    • About
    • Blog
    • Contact
    Sidebar
    Start typing to see products you are looking for.

    Sending...