NewTrend · DC EV Charging
Product overview
DC-T is a three-DC-outlet charging station for commercial charging networks, fleet depots and public sites. It can serve up to three electric vehicles simultaneously while dynamically allocating available power according to real-time vehicle demand. This improves charger utilization and site efficiency without requiring separate stations for every vehicle.
Key features
- Three DC outlets with 5 m charging cables.
- Intelligent power distribution according to vehicle demand.
- 21-inch LCD / LED display reference and RFID / App authorization.
- Ethernet / 4G / WiFi networking and OCPP 1.6J communication.
- Independent forced-air cooling duct.
- Emergency stop, LED indicator, card authorization and touch-screen operation.
- Overvoltage, undervoltage, overload, current-leakage, grounding, overtemperature, surge and fire-protection references.
Model and electrical input
| Model | Rated power | AC input current | Document weight reference |
|---|---|---|---|
| DC90-T | 90 kW | 203 A | ≤370 kg |
| DC120-T | 120 kW | 204 A | ≤375 kg |
| DC150-T | 150 kW | 255 A | ≤390 kg |
| DC160-T | 160 kW | 272 A | ≤395 kg |
| DC180-T | 180 kW | 306 A | ≤405 kg |
| DC200-T | 200 kW | 340 A | ≤415 kg |
| DC210-T | 210 kW | 357 A | ≤425 kg |
| DC240-T | 240 kW | 407 A | ≤445 kg |
| DC270-T | 270 kW | 458 A | ≤455 kg |
| DC280-T | 280 kW | 475 A | ≤460 kg |
| DC300-T | 300 kW | 509 A | ≤475 kg |
| DC320-T | 320 kW | 543 A | ≤485 kg |
| DC440-T | 440 kW | 747 A | ≤540 kg |
| DC480-T | 480 kW | 815 A | ≤555 kg |
Exact supplied weight: To be confirmed. The table retains model-specific document references; shipping weight and packing configuration require confirmation.
Three-outlet connector configuration
Each DC outlet may use CCS1, CCS2, CHAdeMO, GB/T or NACS. The selected connector family indicates the requested interface family; exact mixed-outlet arrangement and complete ordering suffix: To be confirmed.
| Charging outlets | Three DC outlets, A / B / C |
|---|---|
| CCS1 / CCS2 / GB/T / NACS voltage | 150–1000 V DC |
| CHAdeMO voltage | 150–500 V DC |
| CCS1 output current | 0–350 A |
| CCS2 output current | 0–375 A |
| NACS output current | 0–380 A |
| GB/T output current | 0–350 A |
| CHAdeMO output current | 0–150 A |
| Cable length | 5 m |
| AC input voltage | 380–415 V AC, 3P + N + PE |
| Input frequency | 50 / 60 Hz |
| Standby consumption | ≤24 W |
| Efficiency | ≥95% |
| Power factor | ≥0.99 at 100% load |
Construction and controls
| Cabinet | Galvanized sheet |
|---|---|
| Dimensions, L × W × H | 800 × 900 × 1800 mm |
| Packing dimensions, L × W × H | 1050 × 1250 × 2160 mm |
| Installation | Floor-stand |
| Cable routing | Bottom inlet / upper outlet |
| Display | 21-inch LCD / LED reference; number and exact supplied arrangement: To be confirmed |
| Authorization | RFID / App |
| User interface | Emergency stop, LED indicator, card swiping and touch screen |
| Network | Ethernet / 4G / WiFi |
| OCPP | OCPP 1.6J; optional OCPP 2.0 / 2.0.1 applicability: To be confirmed |
| ISO15118-2 / ISO15118-20 | Optional; supplied configuration: To be confirmed |
Environment and protection
| Application | Indoor / outdoor |
|---|---|
| Working altitude | <2000 m |
| Working temperature | −30 °C to +50 °C |
| Storage temperature | −30 °C to +85 °C |
| Humidity | 5–95% |
| Protection | IP55; IK10 cabinet / IK08 display |
| Cooling | Forced-air, independent duct |
| Protection functions | Overvoltage, undervoltage, overload, leakage current, grounding, overtemperature, lightning surge; supplied fire-protection configuration: To be confirmed |
| Warranty | 36-month original-page reference; supplied terms: To be confirmed |
| Certification references | CE, CB and TUV; exact supplied model / market / OEM applicability: To be confirmed |
Charging standards
IEC 61851-21-2:2021; IEC 61000-6-2:2019; EN61000-6-4:2019; IEC 61851-1:2010; EN 61851-23:2014; EN 61851-24:2014; IEC 61851-23:2014; EN 61851-1:2011.
Radio-frequency reference
| Interface / band | Uplink / transmit | Downlink / receive |
|---|---|---|
| RFID | 13.56 MHz | 13.56 MHz |
| WiFi | 2412–2472 MHz | 2412–2472 MHz |
| LTE B1 | 1920–1980 MHz | 2110–2170 MHz |
| LTE B3 | 1710–1785 MHz | 1805–1880 MHz |
| LTE B7 | 2500–2570 MHz | 2620–2690 MHz |
| LTE B8 | 880–915 MHz | 925–960 MHz |
| LTE B20 | 832–862 MHz | 791–821 MHz |
| LTE B28 | 703–748 MHz | 758–803 MHz |
| LTE B38 | 2570–2620 MHz | 2570–2620 MHz |
| LTE B40 | 2300–2400 MHz | 2300–2400 MHz |
| LTE B41 | 2496–2690 MHz | 2496–2690 MHz |
| WiFi maximum output power | 18.82 dBm |
|---|---|
| LTE maximum output power | ≤25 dBm |
Application and dynamic allocation
The energy-storage cabinet shown is an application reference; included system equipment and compatibility: To be confirmed.
Complete family technical document
Download the complete eight-spread technical document
The complete document retains fourteen numbered pages and cover panels, including additional family references outside the selectable scope.